{"product_id":"honeywell-2mlp-acf2-master-logic-plc-power-supply-module","title":"2MLP-ACF2 | Honeywell | Alimentation libre tension","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eProviding regulated system power to Master-Logic 200 backplanes, the \u003cstrong\u003eHoneywell 2MLP-ACF2\u003c\/strong\u003e is a high-efficiency AC-to-DC power supply module engineered for critical control applications. This module accepts a wide universal input voltage range and converts it to a stable 5 VDC system bus voltage to drive local processing and I\/O modules on the rack. Featuring integrated overcurrent protection and diagnostic status reporting, it maintains system integrity in high-demand industrial processing environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUniversal Input:\u003c\/strong\u003e Supports a wide-range input voltage compatibility (Free Voltage) for international industrial networks.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Capacity Rail Output:\u003c\/strong\u003e Delivers a reliable 5 VDC, 6A output to meet the power demands of dense backplane configurations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRobust Protection:\u003c\/strong\u003e Built-in overcurrent and overvoltage protection circuitry automatically safeguards downstream components.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDiagnostic Diagnostics:\u003c\/strong\u003e Features front-facing LED indicators for clear, real-time status monitoring of output states.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThermal Efficiency:\u003c\/strong\u003e Optimized heat dissipation design allows reliable operation within standard enclosed industrial control panels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eDistributed Control Systems (DCS) power distribution networks.\u003c\/li\u003e\n  \u003cli\u003eProcess manufacturing assembly line control panels.\u003c\/li\u003e\n  \u003cli\u003eMunicipal water treatment facility automation racks.\u003c\/li\u003e\n  \u003cli\u003ePower generation and substation monitoring infrastructure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications Table\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #cbd5e0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold; border: 1px solid #e2e8f0;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold; border: 1px solid #e2e8f0;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eHoneywell\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e2MLP-ACF2\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eSeries\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eMaster-Logic 200 (ML200)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eInput Voltage Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e100 to 240 VAC (Free Voltage, 110V \/ 220V nominal)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eInput Frequency\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e50 \/ 60 Hz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eOutput Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e5 VDC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eOutput Current\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e6.0 A\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eEfficiency\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eTypical \u0026gt; 70%\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e0 to 55 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eStorage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e-25 to 70 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eMounting Position\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eDedicated power slot (far-left of backplane)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e2.0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e150 mm x 110 mm x 130 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #cbd5e0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold; border: 1px solid #e2e8f0;\"\u003eTerminal Label\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold; border: 1px solid #e2e8f0;\"\u003eFunction \/ Circuit Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eL\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eAC Live Line Input (100 - 240 VAC)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eN\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eAC Neutral Input\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eFG\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eFrame Ground (must earth directly to cabinet ground bar)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThis power module is specifically engineered to mount to Honeywell Master-Logic 200 series racks. When planning retrofits or replacements of older module versions, ensure the cumulative active 5V current consumption of your processor and I\/O cards does not exceed the unit’s 6.0 A maximum output. Standard base racks do not support parallel multi-power-supply operation for redundancy; only one unit can feed the main bus rail.\u003c\/p\u003e\n\n\u003ch4\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eOperating the module at or near maximum output capacity in unventilated or poorly insulated enclosures can trigger the integrated thermal shutdown loop. To prevent unwanted system downtime, design cabinets with a minimum 50 mm clearance above and below the power module assembly to foster passive convection cooling currents.\u003c\/p\u003e\n\n\u003ch4\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eFor electrical noise reduction, use shielded copper wire with a cross-sectional area of at least 2.0 mm² (14 AWG) for the Frame Ground (FG) hookup. It is critical to feed the module using a dedicated, line-filtered AC supply, independent from high-inductive load paths such as heavy motor starters or variable frequency drives.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e Prior to mounting or performing wiring operations on this hardware, ensure all upstream primary AC power sources are completely locked out and tagged out. Verify there is no residual energy on the lines using a calibrated digital multimeter before contacting terminal blocks.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; color: #2d3748;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"display: flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; width: 30px; height: 30px; border-radius: 50%; flex-shrink: 0; font-weight: bold;\"\u003e1\u003c\/div\u003e\n    \u003cp style=\"margin: 0; padding-top: 3px;\"\u003eEnsure the Master-Logic backplane chassis is securely bolted to the sub-panel ground system before proceeding.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"display: flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; width: 30px; height: 30px; border-radius: 50%; flex-shrink: 0; font-weight: bold;\"\u003e2\u003c\/div\u003e\n    \u003cp style=\"margin: 0; padding-top: 3px;\"\u003eInsert the module's bottom hook guide into the far-left slot position of the base backplane and hinge upward until the top locking mechanism clicks firmly in place.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"display: flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; width: 30px; height: 30px; border-radius: 50%; flex-shrink: 0; font-weight: bold;\"\u003e3\u003c\/div\u003e\n    \u003cp style=\"margin: 0; padding-top: 3px;\"\u003eConnect the Frame Ground (FG) terminal block screw to the local system ground bus with low-impedance copper wire.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"display: flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; width: 30px; height: 30px; border-radius: 50%; flex-shrink: 0; font-weight: bold;\"\u003e4\u003c\/div\u003e\n    \u003cp style=\"margin: 0; padding-top: 3px;\"\u003eWire the AC inputs (L and N) to the terminal block, utilizing insulated ring or spade lugs crimped securely onto the conductor strands.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"display: flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; width: 30px; height: 30px; border-radius: 50%; flex-shrink: 0; font-weight: bold;\"\u003e5\u003c\/div\u003e\n    \u003cp style=\"margin: 0; padding-top: 3px;\"\u003eDouble-check all terminal torque values to prevent loose connection resistance, energize the AC source line, and verify the status LED lights green.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52705602699627,"sku":"2MLP-ACF2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/2mlp-acf2-yg5qwixwuge_e8e9048b-32ca-46f8-a586-04791213e076.jpg?v=1766651400","url":"https:\/\/www.plcprotech.com\/fr\/products\/honeywell-2mlp-acf2-master-logic-plc-power-supply-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}