{"product_id":"honeywell-51304493-200-apm-advanced-process-manager-modem-card","title":"Honeywell-51304493-200 Carte Modem Advanced Process Manager","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eServing as a critical communication bridge within the legacy TDC 3000 control architecture, the \u003cstrong\u003eHoneywell 51304493-200\u003c\/strong\u003e establishes robust, real-time data link connectivity for Advanced Process Manager (APM) systems. This hardware module is designed to interface processing nodes directly with the proprietary \u003cstrong\u003eUniversal Control Network (UCN)\u003c\/strong\u003e, facilitating high-speed deterministic communication. Engineered for severe industrial environments, it maintains high signal integrity and noise immunity under continuous-duty cycles.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual-Channel Redundancy:\u003c\/strong\u003e Supports fully redundant network topologies to prevent communication loss in critical control scenarios.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDirect Slot Integration:\u003c\/strong\u003e Designed for standard APM\/HPM card file slots, minimizing physical footprint and securing optimal backplane interface alignment.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOnboard Diagnostic Indicators:\u003c\/strong\u003e Front-panel LEDs provide immediate visual identification of status, transmit\/receive activity, and hardware fault states.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNoise Immunity:\u003c\/strong\u003e Advanced transceiver circuitry protects critical data lines from electromagnetic interference (EMI) typical in high-voltage industrial plants.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eHoneywell TDC 3000 Distributed Control System (DCS) nodes.\u003c\/li\u003e\n  \u003cli\u003eAdvanced Process Manager (APM) and High-Performance Process Manager (HPM) system communications.\u003c\/li\u003e\n  \u003cli\u003eContinuous process industries including petroleum refining, chemical processing, and power generation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications Table\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eHoneywell\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eModel \/ SKU Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e51304493-200\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eSystem Compatibility\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eHoneywell TDC 3000 APM \/ HPM\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eNetwork Protocol\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eUniversal Control Network (UCN)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eOperating Temperature Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0 to 60 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eStorage Temperature Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-40 to 85 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eRelative Humidity Limits\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e5% to 95% (non-condensing)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1.5 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe 51304493-200 modem card is backward compatible with earlier Honeywell APM files. However, system engineers must verify that the corresponding UCN tap units and active drop cables are rated for the -200 series hardware, as subtle impedence mismatches can cause signal reflection errors on high-traffic networks.\u003c\/p\u003e\n\n\u003ch4\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eIn older control panels, inadequate ventilation can lead to localized heat buildup on the backplane, accelerating component degradation on the modem card. It is crucial to maintain positive airflow within the enclosure to keep ambient temperatures around the module below 55 degC.\u003c\/p\u003e\n\n\u003ch4\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhen replacing an existing modem card, ensure the network coaxial drop cable connections are secured using calibrated torque wrenches. Over-tightening can damage the internal dielectric of the coaxial tap, resulting in intermittent CRC errors on the control console.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cp style=\"color: #9b2c2c; font-weight: bold; margin: 0 0 0.5rem 0;\"\u003eCRITICAL WARNING:\u003c\/p\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eIsolate all electrical power sources from the card file cage before inserting or removing the communication board. Failure to follow electrostatic discharge (ESD) and safety isolation guidelines can cause permanent component failure or disrupt active plant process lines.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"display: flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; min-width: 28px; height: 28px; border-radius: 50%; font-weight: bold;\"\u003e1\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 2px;\"\u003eEnsure a calibrated ESD wrist strap is properly grounded and securely attached to your wrist.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"display: flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; min-width: 28px; height: 28px; border-radius: 50%; font-weight: bold;\"\u003e2\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 2px;\"\u003eVerify that the redundant partner card is actively handling network communications prior to pulling the module to be replaced.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"display: flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; min-width: 28px; height: 28px; border-radius: 50%; font-weight: bold;\"\u003e3\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 2px;\"\u003eAlign the 51304493-200 card with the correct card file guide rails and slide it in until the connector mates securely with the backplane.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"display: flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; min-width: 28px; height: 28px; border-radius: 50%; font-weight: bold;\"\u003e4\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 2px;\"\u003eTighten any securing faceplate fasteners and reconnect the coaxial drop cables, verifying that the physical link LEDs indicate active status.\u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52705317388651,"sku":"51304493-200","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/51304493-200-hb2afvbicvm_31b15826-722b-4689-82ec-fcf2193db136.jpg?v=1766639676","url":"https:\/\/www.plcprotech.com\/fr\/products\/honeywell-51304493-200-apm-advanced-process-manager-modem-card","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}