{"product_id":"honeywell-51309204-175-mc-tlpa02-tdc-3000-power-adapter-board","title":"51309204-175 | Honeywell | Adaptateur d'alimentation MC-TLPA02","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell MC-TLPA02\u003c\/strong\u003e is a conformally coated Power Adapter board designed for the High-Performance Process Manager (HPM) subsystem within the TDC 3000 \/ TotalPlant Solution (TPS) architecture. It provides essential communication routing and power interfacing between an Input\/Output Processor (IOP), such as the \u003cstrong\u003eMU-PLAM02\u003c\/strong\u003e or \u003cstrong\u003eMC-PLAM02\u003c\/strong\u003e Low Level Multiplexer (LLMux) IOP, and corresponding Field Termination Assemblies (FTAs). The board plays a critical role in integrating temperature measurement devices and serial interfaces into the core control system, enabling seamless data flow across the Universal Control Network (UCN).\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConformal Coating\u003c\/strong\u003e: Specifically treated to protect electronic circuitry against moisture, corrosion, and harsh environmental contaminants.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Interoperability\u003c\/strong\u003e: Establishes a communication bridge between the LLMux IOP and up to two Thermocouple (TC) or Resistive Temperature Device (RTD) FTAs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Application\u003c\/strong\u003e: Supports both non-CE Compliant and CE Compliant configurations when deployed with appropriate Honeywell cabling and card files.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended Cable Support\u003c\/strong\u003e: Accommodates internal cabinet and external cabinet cabling configurations to support remote hardware distribution.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLow Level Analog Input Multiplexer (LLMux) configurations for RTD and Thermocouple sensors.\u003c\/li\u003e\n\u003cli\u003eSerial Device Interface (SDI) and Serial Interface (SI) power adapter placements.\u003c\/li\u003e\n\u003cli\u003ePetrochemical, refining, and continuous heavy industrial processing plants utilizing Honeywell TDC 3000 \/ TPS automation frameworks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMC-TLPA02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e51309204-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConformal Coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85-265 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTDC 3000 \/ TPS High-Performance Process Manager (HPM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated IOP Models\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMU-PLAM02 \/ MC-PLAM02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated FTA Models\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMU-TAMR03, MC-TAMR03, MU-TAMT03, MC-TAMT03, MU-TAMT13, MC-TAMT13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE Compliance\u003c\/strong\u003e: For CE Compliant installations, the power adapter must be interconnected using the model MU-KFTSxx IOP to FTA cable and the corresponding IOP must be seated in a CE Compliant card file.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCabinet Placement\u003c\/strong\u003e: The board is designed for physical placement alongside relevant card files or within standard vertical\/horizontal mounting channels depending on configuration constraints.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding\u003c\/strong\u003e: Ensure all external cabinet cabling shields are terminated appropriately at both the Power Adapter end and the FTA end to avoid signal degradation or interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Cabling\u003c\/strong\u003e: All incoming AC power cabling and high-current wires should follow standard separation guidelines from low-level signal pairs within the cabinet routing channels.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52705332494699,"sku":"MC-TLPA02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/51309204-175-c4u5cjgdv5z_d25a90ae-6d2b-4da3-b5e8-cc255bd4c933.jpg?v=1766640672","url":"https:\/\/www.plcprotech.com\/fr\/products\/honeywell-51309204-175-mc-tlpa02-tdc-3000-power-adapter-board","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}