{"product_id":"honeywell-cc-tdor01-experion-series-c-digital-output-relay-module","title":"CC-TDOR01 | Honeywell | Module de Relais de Sortie Numérique","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eManaging field-level discrete switching signals within the Experion PKS architecture is the primary function of the \u003cstrong\u003eHoneywell CC-TDOR01\u003c\/strong\u003e. This Series C Digital Output Relay Input Output Termination Assembly (IOTA) interfaces controller-level logic with physical field relays, providing robust galvanic isolation and signal replication. Engineered for heavy industrial deployments, the module facilitates reliable command execution from the control processor to field-level actuators, indicator lamps, and solenoid valves while protecting internal system electronics from external electrical transients.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.2rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003e16 Isolated Channels:\u003c\/strong\u003e Accommodates up to 16 independent digital output relay circuits on a single board layout.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConformal Coating:\u003c\/strong\u003e Standard environmental protection shields circuitry from airborne contaminants, moisture, and corrosive gases.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDirect Controller Interface:\u003c\/strong\u003e Connects seamlessly with Experion Series C Digital Output (DO) modules via the standard I\/O link.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRobust Field Wiring:\u003c\/strong\u003e Integration of high-quality compression screw terminals ensures secure, vibration-resistant field connections.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSimplified Maintenance:\u003c\/strong\u003e Facilitates easy component swap-outs without interrupting adjacent process loops.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.2rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSolenoid Valve Actuation:\u003c\/strong\u003e Controlling pneumatic and hydraulic solenoids in process safety systems.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMotor Control Centers (MCC):\u003c\/strong\u003e Providing interlock signals and auxiliary relay contact commands to motor starters.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVisual and Audible Annunciation:\u003c\/strong\u003e Controlling beacons, horns, and status indicators in control rooms and processing areas.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRefinery and Petrochemical Systems:\u003c\/strong\u003e Deployable in hazardous environments complying with standard industrial certifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; font-size: 0.95rem; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0; text-align: left;\"\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold; color: #1a365d;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold; color: #1a365d;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eHoneywell\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eCC-TDOR01\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eSeries Name\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eExperion Series C\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eModule Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eDigital Output Relay IOTA\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eNumber of Channels\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e16 Channels\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eChannel Configuration\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eNon-Redundant\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eNominal Output Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e24 VDC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eConnection Style\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eCompression Screw Terminals\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0 to 60 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eStorage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-40 to 85 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eRelative Humidity\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e5% to 95% RH (non-condensing)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e5.0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\n\u003ch3\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe Honeywell CC-TDOR01 is a non-redundant, 16-channel Digital Output Relay IOTA. It is designed to work in conjunction with the CC-PDOB01 Digital Output 24V module. In applications requiring full system redundancy, engineering systems should specify the \u003cstrong\u003eCC-TDOR11\u003c\/strong\u003e IOTA, which supports redundant DO module pairings. Verify that matching backplanes and termination styles align with structural panel design before hot-swapping control cards.\u003c\/p\u003e\n\n\u003ch3\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhen switching highly inductive field loads (such as heavy solenoid valves or interposing relays), voltage spikes can occur during contact opening, which degrades relay lifecycle. System engineers must install external suppression devices—such as flyback diodes for DC loads or RC snubbers for AC loads—directly across the field device. This step is critical to prevent contact welding and electromagnetic interference (EMI) within the Series C cabinet.\u003c\/p\u003e\n\n\u003ch3\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDuring initial system commission, ensure field wiring is stripped to 6mm to prevent exposure of bare copper. Ensure that high-voltage power routing does not pass parallel to the low-voltage communication and I\/O link cables. Always use shielded, twisted-pair cabling for field signals that cross electrically noisy environments, grounding the shield strictly at the panel-entry grounding bar and not at both ends to avoid ground loops.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; border-radius: 4px;\"\u003e\n  \u003cp style=\"color: #9b2c2c; font-weight: bold; margin: 0 0 0.5rem 0;\"\u003eCRITICAL WARNING\u003c\/p\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0; font-size: 0.95rem;\"\u003eRisk of electric shock and equipment damage. Ensure all control power and field power loops connected to the IOTA are fully de-energized, locked out, and tagged out before mounting, wiring, or servicing the assembly.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 2rem; height: 2rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e1\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 0.2rem;\"\u003eMount the CC-TDOR01 IOTA securely onto the Experion Series C carrier channel, engaging both the top and bottom DIN-rail clips.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 2rem; height: 2rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e2\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 0.2rem;\"\u003eEstablish a low-impedance connection to the cabinet safety ground utilizing the grounding screw on the assembly plate.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 2rem; height: 2rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e3\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 0.2rem;\"\u003ePlug the matching CC-PDOB01 Series C DO module into the IOTA socket, ensuring the board guides line up correctly and the locking mechanism engages.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 2rem; height: 2rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e4\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 0.2rem;\"\u003eWire the field devices to the appropriate compression screw terminals based on your site-specific design wiring diagram.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 2rem; height: 2rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e5\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 0.2rem;\"\u003ePerform continuity and loop verification tests prior to applying operating control power.\u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52705316077931,"sku":"CC-TDOR01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/CC-TDOR01-4ai1aeox4ac_d08b4d59-1931-41d3-8152-f8dd6e86fd8e.jpg?v=1766639642","url":"https:\/\/www.plcprotech.com\/fr\/products\/honeywell-cc-tdor01-experion-series-c-digital-output-relay-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}