{"product_id":"honeywell-fc-iota-r24-redundant-io-termination-assembly","title":"FC-IOTA-R24 | Honeywell | Ensemble de terminaison E\/S redondante","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  Integrating directly into high-availability industrial architectures, the Honeywell FC-IOTA-R24 serves as a robust interface designed to manage redundant input\/output module routing. Engineered specifically for safety-critical environments, this \u003cstrong\u003eredundant I\/O termination assembly\u003c\/strong\u003e ensures continuous process execution by handling split redundant signal paths. It provides dependable field-wiring landing points while maintaining strict electrical and physical separation to preserve safety loop integrity.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual Module Architecture:\u003c\/strong\u003e Supports redundant physical I\/O configurations for fault-tolerant, high-availability process control.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOvercurrent and Polarity Protection:\u003c\/strong\u003e Integrated parallel diode routing ensures fast circuit clearance if reverse polarity occurs.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial Environmental Rating:\u003c\/strong\u003e Designed to withstand extreme temperatures ranging from -40 to +70 degC.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh Load Capability:\u003c\/strong\u003e Formulated to support a maximum supply load current of up to 10 A at nominal 24 Vdc.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1rem;\"\u003e\n  \u003cli\u003eEmergency Shutdown (ESD) and Safety Instrumented Systems (SIS).\u003c\/li\u003e\n  \u003cli\u003eCritical process industries including petrochemical, refining, and power generation.\u003c\/li\u003e\n  \u003cli\u003eDistributed Control System (DCS) redundant safety field landing configurations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eSpecification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eHoneywell\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eFC-IOTA-R24\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eRedundant IO Termination Assembly\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eSupply Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e24 Vdc (-15% to +30%)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eSupply Load\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eMax. 10 A\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eReverse Polarity Protection\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eParallel diode (triggers upstream fuse clearance)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e-40 to +70 degC (-40 to +158 degF)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eStorage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e-40 to +85 degC (-40 to +185 degF)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eRelative Humidity\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e10% to 95% (non-condensing)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003ePollution Degree\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003ePollution degree 2 or better\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eApprovals\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eCE; UL, TUV pending\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eDimensions (L x W x H)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e44.32 cm x 12.07 cm x 6.4 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eNet Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e0.6 Kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e2.0 Kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.25rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  This redundant termination board is designed specifically to interface with compatible safety-certified controller lines. Verify your controller's hardware platform variant and ensure both primary and secondary safety I\/O units maintain matching firmware levels to avoid dual-path sync faults.\n\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.25rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  Keep in mind that the integrated reverse polarity protection utilizes a parallel diode. A reversed input connection causes the diode to short-circuit the supply path to clear the inline fuse. Ensure your power distribution architecture includes appropriate external current limiting to prevent thermal damage to the internal board traces before the external fuse clears.\n\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.25rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  Keep high-voltage power lines isolated from low-voltage field signal terminations on this board. Maintain solid chassis grounding points to mitigate common-mode noise on the redundant field cables.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; border-radius: 4px;\"\u003e\n  \u003cp style=\"margin: 0; font-weight: bold; color: #9b2c2c;\"\u003eCRITICAL WARNING\u003c\/p\u003e\n  \u003cp style=\"margin: 0.5rem 0 0 0; color: #9b2c2c;\"\u003e\n    Isolate and de-energize all primary and redundant 24 Vdc supply lines before mounting or terminating. Verify complete discharge of electrical charges using calibrated instruments before handling. Non-compliance risks equipment failure and personal injury.\n  \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n  \u003cp style=\"margin: 0; color: #2d3748;\"\u003eMount the assembly securely inside a dust-free, vibration-isolated cabinet enclosure rated for Pollution Degree 2 or better.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n  \u003cp style=\"margin: 0; color: #2d3748;\"\u003eTerminate redundant 24 Vdc power lines, ensuring the polarity is carefully verified and cross-referenced with your wiring schematics.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n  \u003cp style=\"margin: 0; color: #2d3748;\"\u003eConnect both redundant I\/O module bus cables to the dedicated connection ports and clamp them firmly down to prevent accidental vibration loosening.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52705312604523,"sku":"FC-IOTA-R24","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/fc-iota-r24-rjzrzltot4d_f9d5dd70-1642-4059-804d-1fce429be3b7.jpg?v=1766639554","url":"https:\/\/www.plcprotech.com\/fr\/products\/honeywell-fc-iota-r24-redundant-io-termination-assembly","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}