{"product_id":"honeywell-fs-psu-240516-cc-v1-1-safety-manager-power-supply-unit","title":"Unité d'alimentation Safety Manager CC V1.1 Honeywell FS-PSU-240516","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDesigned for seamless integration into high-integrity safety architectures, this \u003cstrong\u003eHoneywell FS-PSU-240516 CC V1.1\u003c\/strong\u003e power supply module converts and regulates input power to sustain demanding system logic loads. Purpose-built for the Honeywell Safety Manager and Fail Safe Controller (FSC) systems, it provides stabilized \u003cstrong\u003e24 Vdc and 5 Vdc outputs\u003c\/strong\u003e with a combined capacity of \u003cstrong\u003e16 A\u003c\/strong\u003e. The \u003cstrong\u003eCC designation\u003c\/strong\u003e denotes conformal coating, providing superior resistance against moisture, dust, and corrosive industrial atmospheric agents.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.25rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eConformal Coated (CC):\u003c\/strong\u003e Enhanced circuit board protection for installation in harsh, corrosive Class G3 environments.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eDual-Output Capabilities:\u003c\/strong\u003e Delivers concurrent power regulation for 24 Vdc safety loops and 5 Vdc internal chassis logic.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eRobust Low Inrush Design:\u003c\/strong\u003e Restricts inrush current to less than 5 A at nominal 24 Vin to prevent upstream breaker tripping.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eCritical Fault Tolerance:\u003c\/strong\u003e Engineered to provide immediate power bridging during brief mains disruptions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.25rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eEmergency Shutdown Systems (ESD) and Fire and Gas (F\u0026amp;G) monitoring networks.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eBurner Management Systems (BMS) in chemical processing facilities and power generation plants.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eCritical infrastructure process control loops requiring certified SIL-rated safety architectures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem 0.5rem; font-weight: bold; width: 35%;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem 0.5rem;\"\u003eHoneywell\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem 0.5rem; font-weight: bold;\"\u003eModel \/ SKU\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem 0.5rem;\"\u003eFS-PSU-240516 CC V1.1\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem 0.5rem; font-weight: bold;\"\u003eNominal Output Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem 0.5rem;\"\u003e24 Vdc and 5 Vdc\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem 0.5rem; font-weight: bold;\"\u003eMaximum Rated Current\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem 0.5rem;\"\u003e16 A\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem 0.5rem; font-weight: bold;\"\u003eInput Supply Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem 0.5rem;\"\u003e24 Vdc (-15% to +30%)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem 0.5rem; font-weight: bold;\"\u003eInrush Current\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem 0.5rem;\"\u003eLess than 5 A at 24 Vin\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem 0.5rem; font-weight: bold;\"\u003eHold-up Time\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem 0.5rem;\"\u003eLess than 1 ms\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem 0.5rem; font-weight: bold;\"\u003eConformal Coating\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem 0.5rem;\"\u003eYes (CC version)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem 0.5rem; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem 0.5rem;\"\u003e-5 degC to +70 degC (+23 degF to +158 degF)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem 0.5rem; font-weight: bold;\"\u003eStorage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem 0.5rem;\"\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem 0.5rem; font-weight: bold;\"\u003eRelative Humidity\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem 0.5rem;\"\u003e10% to 95% (non-condensing)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem 0.5rem; font-weight: bold;\"\u003eDimensions (L x W x H)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem 0.5rem;\"\u003e21.2 cm x 3.52 cm x 17.6 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem 0.5rem; font-weight: bold;\"\u003eNet Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem 0.5rem;\"\u003e0.85 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem 0.5rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem 0.5rem;\"\u003e3.00 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem 0.5rem; font-weight: bold;\"\u003eSystem Certifications\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem 0.5rem;\"\u003eCE, TUV, UL, CSA, FM\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.25rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThis model replaces standard non-conformal coated variations (FS-PSU-240516). Systems requiring backward compatibility with firmware Safety Manager R120 or earlier must verify card-carrier physical clearances and revision profiles, as version 1.1 features an optimized heat-sink footprint.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.25rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhen housing multiple FS-PSU modules within a tightly enclosed safety panel, thermal stratification can lead to accelerated component aging. Maintain a minimum vertical spacing clearance of 50 mm above and below the card chassis to permit convection airflow and ensure the ambient local temperature remains below +70 degC.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.25rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eAlways verify feed circuit supply integrity. The input tolerance allows 24 Vdc input variations from -15% to +30%, but keeping the incoming voltage at a stable nominal 24 Vdc optimizes internal regulator efficiency and minimizes excessive heat dissipation within the module's enclosure.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING: SAFETY FIRST\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0; font-size: 0.95rem;\"\u003eIsolate and lockout all active primary power feeds prior to physical module replacement. Working on energized components in safety-instrumented systems poses severe risks of accidental ESD system trip, electrical shock, and hardware degradation.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 0.75rem;\"\u003e\n  \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0; font-size: 0.85rem;\"\u003e1\u003c\/span\u003e\n  \u003cspan style=\"color: #2d3748;\"\u003eEnsure the power supply card frame is securely connected to the system functional earth ground network.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 0.75rem;\"\u003e\n  \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0; font-size: 0.85rem;\"\u003e2\u003c\/span\u003e\n  \u003cspan style=\"color: #2d3748;\"\u003eAlign the backplane guide pin connectors carefully before pushing the FS-PSU module into the rack slot.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 0.75rem;\"\u003e\n  \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; font-weight: bold; margin-right: 10px; flex-shrink: 0; font-size: 0.85rem;\"\u003e3\u003c\/span\u003e\n  \u003cspan style=\"color: #2d3748;\"\u003eTighten the retaining screws securely to a torque of 0.5 Nm to prevent vibration-induced contact resistance.\u003c\/span\u003e\n\u003c\/div\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52705314373995,"sku":"FS-PSU-240516 CC V1.1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/fs-psu-240516ccv1.1-hebz3qqv3r5_5c0e5345-adae-41a1-8470-d9928e4940ad.jpg?v=1766639595","url":"https:\/\/www.plcprotech.com\/fr\/products\/honeywell-fs-psu-240516-cc-v1-1-safety-manager-power-supply-unit","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}