{"product_id":"honeywell-mu-tamt02-tdc-3000-low-level-analog-input-multiplexer","title":"Multiplexeur d'entrée analogique bas niveau TDC 3000 Honeywell MU-TAMT02","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDistributed control systems rely on robust field termination architectures for clean signal processing. The \u003cstrong\u003eMU-TAMT02\u003c\/strong\u003e functions as a specialized \u003cstrong\u003elow level analog input multiplexer\u003c\/strong\u003e Field Termination Assembly (FTA) within the legacy Honeywell TDC 3000 control system framework. This module is engineered to consolidate up to 16 low-level analog input channels, primarily interfacing with thermocouple (TC) field sensors. By multiplexing these field signals, the unit significantly reduces physical field wiring footprints and minimizes the number of high-level I\/O channels required back at the controller rack.\u003c\/p\u003e\n\n\u003cp\u003eOperating as a critical interface link, the \u003cstrong\u003eMU-TAMT02\u003c\/strong\u003e provides essential signal routing, isolation, and integrated cold junction compensation (CJC). These functions preserve the signal integrity of weak millivolt inputs across long transmission lines before digitization. Designed for high availability industrial process plants, this FTA ensures stable communication between field-level thermal sensors and the primary DCS processor.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSupports up to 16 independent low-level analog input channels.\u003c\/li\u003e\n  \u003cli\u003eFeatures integrated onboard cold junction compensation (CJC) for precise thermocouple temperature processing.\u003c\/li\u003e\n  \u003cli\u003eMultiplexes high-density field wiring into a centralized bus to optimize system architecture.\u003c\/li\u003e\n  \u003cli\u003eRobust screw-terminal block connections accommodate industrial wire gauges.\u003c\/li\u003e\n  \u003cli\u003eDirect compatibility with Honeywell TDC 3000 process manager and LLMUX cards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePower generation plant thermal monitoring and turbine temperature logging.\u003c\/li\u003e\n  \u003cli\u003ePetrochemical and oil refining furnace monitoring systems.\u003c\/li\u003e\n  \u003cli\u003eChemical processing reactor temperature tracking.\u003c\/li\u003e\n  \u003cli\u003eGeneral metal processing and kiln heat monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eManufacturer\u003c\/strong\u003e\n      \u003ctd\u003eHoneywell\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003ePart Number\/Model\u003c\/strong\u003e\n      \u003ctd\u003eMU-TAMT02\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eSeries\u003c\/strong\u003e\n      \u003ctd\u003eTDC 3000\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eModule Type\u003c\/strong\u003e\n      \u003ctd\u003eLow Level Analog Input Multiplexer Field Termination Assembly (LLMUX FTA)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e\n      \u003ctd\u003e16 channels\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eInput Signal Compatibility\u003c\/strong\u003e\n      \u003ctd\u003eLow-level millivolt \/ Thermocouple (TC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eCompensation Type\u003c\/strong\u003e\n      \u003ctd\u003eOnboard Cold Junction Compensation (CJC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eMounting Configuration\u003c\/strong\u003e\n      \u003ctd\u003eStandard FTA Mounting Channel \/ Panel Mount\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eShipping Weight\u003c\/strong\u003e\n      \u003ctd\u003e5.0 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eTerminal Group\u003c\/th\u003e\n      \u003cth\u003eFunction Description\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTerminals 1 to 16\u003c\/td\u003e\n      \u003ctd\u003eLow-level Analog \/ Thermocouple Input Channels (Positive \/ Negative pairs)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eShield Terminals\u003c\/td\u003e\n      \u003ctd\u003eDedicated shield-drain ground connections for noise reduction\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSystem Cable Interface\u003c\/td\u003e\n      \u003ctd\u003eMulti-pin connector interfacing directly with LLMUX controller cards\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eAlways ensure proper grounding of thermocouple shield drains to the local cabinet ground bus to minimize electromagnetic interference.\u003c\/li\u003e\n  \u003cli\u003eInstall the module inside a clean, dust-free protective industrial enclosure that maintains stable thermal conditions for optimal CJC accuracy.\u003c\/li\u003e\n  \u003cli\u003eDo not route low-level sensor cabling parallel to high-voltage, high-current power cables or AC motor drive lines.\u003c\/li\u003e\n  \u003cli\u003eIsolate field power before connecting or disconnecting the FTA interface cables to avoid transient damage to the multiplexer circuitry.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52705316209003,"sku":"MU-TAMT02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/MU-TAMT02-dculr3fcwqz_990264d3-a874-4003-ad80-57df14e9c93d.jpg?v=1766639645","url":"https:\/\/www.plcprotech.com\/fr\/products\/honeywell-mu-tamt02-tdc-3000-low-level-analog-input-multiplexer","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}