{"product_id":"honeywell-tc-ixr061-experion-pks-analog-input-module","title":"Honeywell TC-IXR061 Module d'entrée analogique Experion PKS","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTC-IXR061 (TCIXR061)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision, galvanically isolated analog input module designed for the Honeywell Experion PKS (Process Knowledge System) platform. In critical process industries such as hydrocarbon processing, large-scale chemical synthesis, and pharmaceutical manufacturing, signal integrity is non-negotiable. This module provides six channels of isolated measurement, shielding the control system from ground loops and high-voltage transients commonly found in heavy industrial environments. By providing a rapid module update rate of 50 ms and integrated open-wire detection, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTC-IXR061\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures that operators receive immediate, accurate data for closed-loop control. This proactive diagnostic capability is vital for identifying field instrument failures before they lead to emergency shutdowns, thereby maximizing plant availability and safety.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTC-IXR061\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis engineered to maintain high-fidelity signal conversion under challenging electromagnetic conditions. Its architecture emphasizes both speed and environmental resilience.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEach of the 6 channels is individually isolated, preventing common-mode noise and ground-current interference from migrating across the I\/O backplane.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid Processing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module features a comprehensive update rate of 50 ms for all channels, making it suitable for fast-acting control loops and sensitive monitoring applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust RFI Immunity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned to withstand high-frequency interference, the module maintains an error rate of less than 2.0 percent even in the presence of 10 V\/m radio frequency fields.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostic Reporting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBuilt-in open-wire detection triggers an \"Out of Range\" status in less than 5 seconds, allowing for rapid fault localization in the field wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTC-IXR061\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGalvanically Isolated Analog Input\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Points\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUpdate Rate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 ms (All channels)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChannel Bandwidth\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDC to 15 Hz (-3 dB)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.3 W Maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTerminal Block\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTC-TBNH (20-position)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOpen Wire Detection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eReported in less than 5 seconds\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.3 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the TC-IXR061 handle field wiring breaks?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module includes integrated open-wire detection. If a connection is lost, the system reports an \"Out of Range\" value within 5 seconds. This allows the Experion PKS control strategy to transition to a predefined safe state or shed the loop to manual.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of the galvanic isolation on this specific module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStandard analog inputs often share a common ground, which can introduce noise if field instruments are grounded at different potentials. The galvanic isolation in the TC-IXR061 ensures each channel is electrically independent, significantly improving accuracy in \"electrically noisy\" plants.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module compatible with standard Experion PKS chassis?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, it is designed for standard Honeywell I\/O racks and utilizes the TC-TBNH 20-position terminal block for field terminations.\u003c\/p\u003e\n\u003ch3\u003e\n\u003cspan\u003eEngineering \u0026amp; Installation Guide\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShielding and Grounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor optimal performance in environments with high RFI (Radio Frequency Interference), use high-quality twisted-pair shielded cable. Ensure the shield is terminated at the designated ground point on the Honeywell chassis and remains floating at the field instrument side to prevent the very ground loops the module is designed to isolate.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTC-IXR061\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edissipates up to 4.3 W. In high-density I\/O cabinets, ensure that the rack is ventilated properly. Maintain at least 2 inches of clearance at the top and bottom of the chassis to allow natural convection, preventing heat-related drift in the analog-to-digital conversion circuitry.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring Precision:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen utilizing the TC-TBNH terminal block, ensure all connections are torqued according to Honeywell standard specifications. Loose connections on high-impedance analog inputs can lead to intermittent \"Out of Range\" alarms and erratic signal behavior.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52705780433259,"sku":"TC-IXR061","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/TC-IXR061-cbuxtnyz42q_8484f572-fe64-4515-8714-b5aef72c58da.jpg?v=1766659707","url":"https:\/\/www.plcprotech.com\/fr\/products\/honeywell-tc-ixr061-experion-pks-analog-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}