{"product_id":"honeywell-tk-fpcxx2-c200-power-supply-module","title":"Module d'alimentation Honeywell TK-FPCXX2 C200","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eTK-FPCXX2\u003c\/strong\u003e is a chassis-mounted hardware component configured as a dedicated \u003cstrong\u003ePower Supply Module\u003c\/strong\u003e within the Honeywell C200 and Experion control system architecture. This module provides critical voltage conversion and stabilization functions, transforming high-voltage alternating current (AC) source inputs into clean, regulated direct current (DC) power required to operate internal backplane components and adjacent process controllers. It features a user-selectable dual input voltage configuration range to ensure adaptability across varying international electrical distribution systems. Built with internal filtering and surge supression mechanisms, the hardware dampens transient line anomalies and manages thermal dissipation profiles effectively to ensure continuous loop uptime in harsh processing environments.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSelectable dual-range alternating current input configurations.\u003c\/li\u003e\n\u003cli\u003eHigh thermal tolerance delivering steady-state output performance up to 60 Celsius.\u003c\/li\u003e\n\u003cli\u003eManaged inrush current mitigation protecting internal circuit pathways.\u003c\/li\u003e\n\u003cli\u003eCompact physical footprint optimized for standard chassis integration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMain infrastructure power delivery for C200 controller racks.\u003c\/li\u003e\n\u003cli\u003eDistributed Control Systems (DCS) system-tier power regulation.\u003c\/li\u003e\n\u003cli\u003eCritical processor rack utility support in petrochemical and refinery plants.\u003c\/li\u003e\n\u003cli\u003eSubsystem automation power alignment inside power generation facilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTK-FPCXX2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePower Supply Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eC200 \/ Experion System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e85-132 VAC or 170-265 VAC (selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e150 VA, 92 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Inrush Current\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e47-63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Power Output Maximum\u003c\/td\u003e\n\u003ctd\u003e70 W @ 60 Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (L x D x H)\u003c\/td\u003e\n\u003ctd\u003e11.2 x 14.5 x 14.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.1 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e2.5 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eUnited States \/ Global Operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003ch3\u003eInput Voltage Selection\u003c\/h3\u003e\n\u003cp\u003ePrior to mounting the module or applying primary power, explicitly verify the position of the input voltage selection mechanism. Ensure it matches the local plant supply network (85-132 VAC or 170-265 VAC) to prevent immediate terminal or internal structural component damage.\u003c\/p\u003e\n\u003ch3\u003eGrounding and Shielding\u003c\/h3\u003e\n\u003cp\u003eSecurely bond the primary equipment chassis rack to the main factory instrument ground grid via a heavy-gauge low-impedance copper strap. Ensure structural backplane grounding points are free of non-conductive coatings to guarantee continuous path integrity.\u003c\/p\u003e\n\u003ch3\u003eCooling and Ventilation\u003c\/h3\u003e\n\u003cp\u003eThe module dissipates operational heat and is rated for a maximum of 70 W output at 60 Celsius. Maintain free vertical spacing and clear ventilation lanes above and below the installation rack to facilitate unhindered air convection across the enclosure.\u003c\/p\u003e\n\u003ch3\u003eWiring and Inrush Considerations\u003c\/h3\u003e\n\u003cp\u003eEnsure incoming power feed wiring is sized appropriately to handle the maximum rated 15 A inrush current transient during initialization cycles. Route AC mains distribution cables through separate physical containment channels away from sensitive analog or communication lines to minimize cross-talk.\u003c\/p\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the core function of this module within the chassis?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt converts standard factory AC mains utility voltage into the stabilized DC power required by the backplane to drive local control logic.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the incoming AC voltage range configured on this hardware?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module features a selectable input interface that accommodates either 85-132 VAC or 170-265 VAC utility lines.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat frequency limits does the power input stage support?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe internal transformer and filtering elements operate across a standard frequency range of 47-63 Hz.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the peak inrush current during initial power-up?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module exhibits a maximum transient inrush current of up to 15 A when power is first applied.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum output wattage at elevated temperatures?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe hardware delivers a total continuous power output maximum of 70 W when operating at temperatures up to 60 Celsius.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the exact physical dimensions of the module housing?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe unit dimensions measure 11.2 cm in length, 14.5 cm in depth, and 14.0 cm in height.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this power supply require active fan cooling?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt relies on passive convection cooling provided that specified layout clearance and ambient environment thresholds are strictly maintained.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the total volt-ampere and wattage ratings for input power consumption?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe maximum input power ratings are specified at 150 VA and 92 W.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the net unboxed weight of the standalone hardware assembly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe individual power module has a net physical weight of exactly 1.1 Kg.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat steps are needed to secure the module against vibration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSlide the module along the chassis guide rails until it seats firmly into the backplane, then lock the integrated mechanical fasteners tightly.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52705314144619,"sku":"TK-FPCXX2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/TK-FPCXX2-irdnuwy1gy3_a38ed60b-b7e4-4106-b1e6-8fa9549272e0.jpg?v=1766639589","url":"https:\/\/www.plcprotech.com\/fr\/products\/honeywell-tk-fpcxx2-c200-power-supply-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}