{"product_id":"honeywell-tk-ioli01-experion-pks-i-o-link-module","title":"Module de liaison E\/S Experion PKS Honeywell TK-IOLI01","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eTK-IOLI01\u003c\/strong\u003e is a high-performance communication interface designated as an \u003cstrong\u003eI\/O Link Module\u003c\/strong\u003e (\u003cstrong\u003eIOLIM\u003c\/strong\u003e) designed for integration within Honeywell Experion PKS distributed control systems (DCS). This module serves as a specialized gateway and network bridge, establishing deterministic communication links between the primary process controller architecture and traditional Process Manager I\/O (\u003cstrong\u003ePMIO\u003c\/strong\u003e) subsystems. By converting internal control network protocols into physical layer signals required by legacy or remote rack hardware, it enables seamless system expansion and co-existence of multi-generational automation platforms. It preserves previous physical plant capital investments while maintaining the sub-millisecond execution speeds and structural diagnostic reporting necessary for stable process industries.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eActs as a dedicated hardware interface bridge (IOLIM) to legacy and remote PMIO structures.\u003c\/li\u003e\n\u003cli\u003eFacilitates real-time, bi-directional database and signal mapping between processing units.\u003c\/li\u003e\n\u003cli\u003eSupports high-reliability system synchronization for time-critical industrial loops.\u003c\/li\u003e\n\u003cli\u003eStandardized form factor ensuring native chassis-slot compatibility.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDistributed Control Systems (DCS) link expansions.\u003c\/li\u003e\n\u003cli\u003eIntegration of Process Manager I\/O (PMIO) segments into newer Experion control topologies.\u003c\/li\u003e\n\u003cli\u003eInfrastructure modernization across petrochemical, chemical processing, and refinery controls.\u003c\/li\u003e\n\u003cli\u003eMulti-rack coordination in large-scale thermal power generation plant facilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTK-IOLI01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eI\/O Link Module (IOLIM \/ IIOLIM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCore System Compatibility\u003c\/td\u003e\n\u003ctd\u003eDirect Control Systems \/ Experion PKS Architecture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTarget Interface\u003c\/td\u003e\n\u003ctd\u003eProcess Manager I\/O (PMIO) Subsystems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e3.5 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eUnited States \/ Global Operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDocumentation Reference\u003c\/td\u003e\n\u003ctd\u003eConsult the PMIO Specification Document for full operational topologies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003ch3\u003eGrounding and Shielding\u003c\/h3\u003e\n\u003cp\u003eVerify that the host controller chassis is properly connected to the structural plant instrumentation grounding grid via a dedicated low-impedance copper bus bar. Ensure all communication network cable shields are grounded at a single, isolated termination point to suppress electromagnetic interference and prevent ground-loop current generation.\u003c\/p\u003e\n\u003ch3\u003eHandling and ESD Protection\u003c\/h3\u003e\n\u003cp\u003eThe module incorporates highly sensitive communication circuits vulnerable to electrostatic discharge (ESD). Technical personnel must wear an approved, bonded static-dissipative wrist strap before opening any packaging, configuring backplane address switches, or inserting the unit into the physical rack slot.\u003c\/p\u003e\n\u003ch3\u003eInsertion and Power Constraints\u003c\/h3\u003e\n\u003cp\u003eIsolate or verify rack segment safety parameters prior to insertion. Align the module card edges precisely with the upper and lower guide rails of the chassis, pushing firmly until the rear connectors mate with the backplane. Secure the mechanical locking screws to prevent loose connection errors under continuous operational vibration.\u003c\/p\u003e\n\u003ch3\u003eCommunication Routing and Verification\u003c\/h3\u003e\n\u003cp\u003eLay out all I\/O link cable assemblies separate from high-voltage AC\/DC power infrastructure to limit radio frequency cross-talk. Refer directly to the official Honeywell PMIO Specification document for maximum allowable physical length and termination resistance parameters required to preserve link signal integrity.\u003c\/p\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the core function of this communication module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt acts as an I\/O Link Module providing a dedicated communication path between modern controllers and PMIO sub-networks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this device manage field inputs directly like standard I\/O hardware?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, it is a specialized interface module that coordinates data traffic and protocol handling for external PMIO subsystems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhere can the full engineering configuration matrices be reviewed?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAll comprehensive parameters, hardware settings, and architectural guidelines must be cross-referenced via the official Honeywell PMIO Specification document.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the physical net weight of the standalone module assembly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe unboxed hardware module has a net weight of exactly 0.45 Kg.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the total package weight including standard shipping protection?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe total shipping weight for the module kit inside its transport box is rated at 3.5 Kg.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module fit into a standard Experion control chassis assembly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, it is built with the precise dimensional alignment required for standard Honeywell DCS chassis integration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAre there special wiring limits for the underlying link connections?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, precise segment limits, routing instructions, and branch rules are governed by the electrical constraints found in the PMIO engineering standard.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat precautions should be taken regarding static electricity during plant maintenance?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePersonnel must always apply active ESD grounding protocols and wear wrist straps before interacting with the module body or backplane.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this unit be hot-swapped under full plant production loads?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eConsult the master system manual and specific rack safety logs before performing hot-insertion to prevent communications dropouts on running loops.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat sub-classification does the module fall under?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is structurally classified as an I\/O Link Module or IOLIM component for direct control platforms.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52705560592747,"sku":"TK-IOLI01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/TK-IOLI01-e0dznyryzsd_b09cf566-5787-4e1a-b1ce-dce02bd04689.jpg?v=1766649799","url":"https:\/\/www.plcprotech.com\/fr\/products\/honeywell-tk-ioli01-experion-pks-i-o-link-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}