{"product_id":"ic2-30fa3n04-02a2e20f4-acxx-danfoss-ic2-30-frequency-converter","title":"iC2-30FA3N04-02A2E20F4+ACXX Variateur de fréquence Danfoss iC2-30","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e132L6117 (132L6117)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a precision-engineered iC2-30 series frequency converter designed to optimize motor control in compact industrial applications. This air-cooled drive is a critical component for machinery manufacturers in sectors such as food and beverage processing, material handling, and textile production. By providing a stable 0.75 KW output with advanced three-phase modulation, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eiC2-30\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseries effectively reduces mechanical stress and energy consumption. Its compact IP20 design allows for high-density mounting within control cabinets, ensuring maximum uptime and reliability for low-power automated systems where space and thermal efficiency are paramount.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe hardware architecture of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e132L6117\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efollows the robust iC2-30 platform standards, focusing on simplified integration and high power density.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePhase \u0026amp; Voltage Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConfigured for three-phase (3N) mains input ranging from 380-480 VAC, making it compatible with global industrial power standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEmploys a specialized air-cooled (FA) category design, utilizing optimized airflow paths to maintain component integrity during continuous 2.2 A operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtection \u0026amp; Compliance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures an IP20\/Open type (E20) protection rating, intended for clean, dry cabinet environments. The integrated F4 filter ensures compliance with C4 category EMC requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBrake Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis specific variant (+ACXX) does not include an integrated brake chopper, making it an economical and streamlined choice for applications with low-inertia loads that do not require rapid deceleration or regenerative braking.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e132L6117\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eiC2-30\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFull Type Code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIC2-30FA3N04-02A2E20F4+ACXX\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.75 KW\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.2 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMains Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e380-480 VAC (Three-Phase)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20 \/ Open Type\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEMC Class\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC4 Category (F4)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCooling Method\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAir Cooled\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.055 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 132L6117 support permanent magnet motors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the iC2-30 series is designed to control both high-efficiency permanent magnet (PM) motors and standard asynchronous induction motors, allowing for flexible system upgrades.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the mounting clearance requirements for this air-cooled drive?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e132L6117\u003c\/strong\u003e, ensure a minimum vertical clearance of 100 mm above and below the unit to allow for unrestricted airflow through the heat sink, especially when mounting multiple drives in a single row.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this drive be used in a C1 or C2 EMC environment?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe integrated filter is rated for C4 (F4 category). For environments requiring C1 or C2 compliance, an external RFI filter must be installed on the mains side to suppress electromagnetic interference to the required levels.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCabinet Thermal Budgeting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDespite its small 0.75 KW rating, ensure your cabinet's total heat load calculation accounts for the drive's heat dissipation at full 2.2 A load. In high-density installations, forced ventilation of the enclosure is recommended to prevent the drive from entering a thermal derating state.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring for EMC Compliance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo maintain the C4 EMC rating, motor cables must be shielded. The shield should be terminated using a high-frequency 360-degree clamp at both the drive and the motor end. Avoid \"pigtail\" grounding, as this significantly increases high-frequency impedance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLine Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse recommended fast-acting fuses or a circuit breaker sized for the 380-480 VAC input. Ensure that the short-circuit current rating (SCCR) of the installation site does not exceed the drive's rated capacity to prevent catastrophic failure during a fault.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102418624875,"sku":"132L6117","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/132l6117-m1h3xyfdjzu.png?v=1776137045","url":"https:\/\/www.plcprotech.com\/fr\/products\/ic2-30fa3n04-02a2e20f4-acxx-danfoss-ic2-30-frequency-converter","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}