{"product_id":"ic695alg626-ge-fanuc-pacsystems-rx3i-analog-input-module-with-hart","title":"Module d'entrée analogique avec HART GE Fanuc PACSystems RX3i IC695ALG626","description":"\u003ch3 data-section-id=\"1n8lizy\" data-start=\"70\" data-end=\"90\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp data-start=\"91\" data-end=\"539\"\u003e\u003cstrong data-start=\"91\" data-end=\"120\"\u003eIC695ALG626 (IC695ALG626)\u003c\/strong\u003e is a high-resolution analog input module designed for GE Fanuc PACSystems RX3i control platforms. The module provides 16 single-ended or 8 differential analog input channels with integrated HART 5.0 communication capability. Engineers deploy this module in turbine control systems, refinery process skids, power generation monitoring, and critical plant instrumentation where accurate analog acquisition is required.\u003c\/p\u003e\n\u003cp data-start=\"541\" data-end=\"1109\"\u003eThe design integrates four internal HART modems and supports simultaneous analog and digital device diagnostics. Software configuration eliminates hardware jumpers and simplifies commissioning. Built-in autocalibration, advanced filtering, and high noise rejection maintain measurement stability in electrically harsh environments. The module supports voltage and current ranges including 4 to 20 mA loops commonly used in field transmitters. High resolution 24 bit ADC conversion ensures precise process feedback, reducing control drift and unexpected shutdown risks.\u003c\/p\u003e\n\u003ch3 data-section-id=\"11tq92d\" data-start=\"1111\" data-end=\"1138\"\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp data-start=\"1139\" data-end=\"1423\"\u003eThe IC695ALG626 installs into RX3i Universal Backplane and communicates directly with RX3i CPUs. Each channel supports independent configuration for voltage or current inputs. Four internal HART modems multiplex channel groups to enable device diagnostics without additional hardware.\u003c\/p\u003e\n\u003cp data-start=\"1425\" data-end=\"1447\"\u003eThe module supports:\u003c\/p\u003e\n\u003cul data-start=\"1448\" data-end=\"1768\"\u003e\n\u003cli data-section-id=\"19lsbx6\" data-start=\"1448\" data-end=\"1492\"\u003e16 single ended or 8 differential inputs\u003c\/li\u003e\n\u003cli data-section-id=\"1wx1qfr\" data-start=\"1493\" data-end=\"1537\"\u003eHART 5.0 communication per channel group\u003c\/li\u003e\n\u003cli data-section-id=\"16zgnf2\" data-start=\"1538\" data-end=\"1590\"\u003e24 bit ADC conversion with floating point output\u003c\/li\u003e\n\u003cli data-section-id=\"1ge6xva\" data-start=\"1591\" data-end=\"1642\"\u003eSoftware selectable filters from 8 Hz to 500 Hz\u003c\/li\u003e\n\u003cli data-section-id=\"1kcqm7t\" data-start=\"1643\" data-end=\"1690\"\u003ePer channel scaling and alarm configuration\u003c\/li\u003e\n\u003cli data-section-id=\"1nluxzx\" data-start=\"1691\" data-end=\"1721\"\u003eAutocalibration at startup\u003c\/li\u003e\n\u003cli data-section-id=\"6jtyi7\" data-start=\"1722\" data-end=\"1768\"\u003eOpen circuit detection and fault reporting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1770\" data-end=\"1807\"\u003eVoltage and current ranges include:\u003c\/p\u003e\n\u003cul data-start=\"1808\" data-end=\"1937\"\u003e\n\u003cli data-section-id=\"3bzwtp\" data-start=\"1808\" data-end=\"1822\"\u003e0 to 20 mA\u003c\/li\u003e\n\u003cli data-section-id=\"n4msfd\" data-start=\"1823\" data-end=\"1837\"\u003e4 to 20 mA\u003c\/li\u003e\n\u003cli data-section-id=\"doaknk\" data-start=\"1838\" data-end=\"1858\"\u003eplus minus 20 mA\u003c\/li\u003e\n\u003cli data-section-id=\"11ozk6h\" data-start=\"1859\" data-end=\"1878\"\u003eplus minus 10 V\u003c\/li\u003e\n\u003cli data-section-id=\"1n7v04\" data-start=\"1879\" data-end=\"1892\"\u003e0 to 10 V\u003c\/li\u003e\n\u003cli data-section-id=\"qvsy4d\" data-start=\"1893\" data-end=\"1911\"\u003eplus minus 5 V\u003c\/li\u003e\n\u003cli data-section-id=\"f7dxhc\" data-start=\"1912\" data-end=\"1924\"\u003e0 to 5 V\u003c\/li\u003e\n\u003cli data-section-id=\"hfmxgh\" data-start=\"1925\" data-end=\"1937\"\u003e1 to 5 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"nucr17\" data-start=\"1939\" data-end=\"1967\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1969\" data-end=\"2741\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1969\" data-end=\"1998\"\u003e\n\u003ctr data-start=\"1969\" data-end=\"1998\"\u003e\n\u003cth data-start=\"1969\" data-end=\"1981\" data-col-size=\"sm\" class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"1981\" data-end=\"1998\" data-col-size=\"sm\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2028\" data-end=\"2741\"\u003e\n\u003ctr data-start=\"2028\" data-end=\"2051\"\u003e\n\u003ctd data-start=\"2028\" data-end=\"2036\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2036\" data-end=\"2051\"\u003eIC695ALG626\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2052\" data-end=\"2072\"\u003e\n\u003ctd data-start=\"2052\" data-end=\"2060\" data-col-size=\"sm\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2060\" data-end=\"2072\"\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2073\" data-end=\"2101\"\u003e\n\u003ctd data-start=\"2073\" data-end=\"2082\" data-col-size=\"sm\"\u003eSeries\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2082\" data-end=\"2101\"\u003ePACSystems RX3i\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2102\" data-end=\"2142\"\u003e\n\u003ctd data-start=\"2102\" data-end=\"2116\" data-col-size=\"sm\"\u003eModule Type\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2116\" data-end=\"2142\"\u003eAnalog Input with HART\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2143\" data-end=\"2191\"\u003e\n\u003ctd data-start=\"2143\" data-end=\"2154\" data-col-size=\"sm\"\u003eChannels\u003c\/td\u003e\n\u003ctd data-start=\"2154\" data-end=\"2191\" data-col-size=\"sm\"\u003e16 single ended or 8 differential\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2192\" data-end=\"2219\"\u003e\n\u003ctd data-start=\"2192\" data-end=\"2209\" data-col-size=\"sm\"\u003eADC Resolution\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2209\" data-end=\"2219\"\u003e24 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2220\" data-end=\"2271\"\u003e\n\u003ctd data-start=\"2220\" data-end=\"2235\" data-col-size=\"sm\"\u003eInput Ranges\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2235\" data-end=\"2271\"\u003eVoltage and current configurable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2272\" data-end=\"2302\"\u003e\n\u003ctd data-start=\"2272\" data-end=\"2287\" data-col-size=\"sm\"\u003eHART Support\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2287\" data-end=\"2302\"\u003eVersion 5.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2303\" data-end=\"2340\"\u003e\n\u003ctd data-start=\"2303\" data-end=\"2321\" data-col-size=\"sm\"\u003eBackplane Power\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2321\" data-end=\"2340\"\u003e600 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2341\" data-end=\"2379\"\u003e\n\u003ctd data-start=\"2341\" data-end=\"2361\" data-col-size=\"sm\"\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd data-start=\"2361\" data-end=\"2379\" data-col-size=\"sm\"\u003e7.35 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2380\" data-end=\"2414\"\u003e\n\u003ctd data-start=\"2380\" data-end=\"2392\" data-col-size=\"sm\"\u003eIsolation\u003c\/td\u003e\n\u003ctd data-start=\"2392\" data-end=\"2414\" data-col-size=\"sm\"\u003e250 VAC continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2415\" data-end=\"2458\"\u003e\n\u003ctd data-start=\"2415\" data-end=\"2433\" data-col-size=\"sm\"\u003eInput Impedance\u003c\/td\u003e\n\u003ctd data-start=\"2433\" data-end=\"2458\" data-col-size=\"sm\"\u003eGreater than 100 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2459\" data-end=\"2516\"\u003e\n\u003ctd data-start=\"2459\" data-end=\"2484\" data-col-size=\"sm\"\u003eOvervoltage Protection\u003c\/td\u003e\n\u003ctd data-start=\"2484\" data-end=\"2516\" data-col-size=\"sm\"\u003eplus minus 60 VDC continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2517\" data-end=\"2573\"\u003e\n\u003ctd data-start=\"2517\" data-end=\"2542\" data-col-size=\"sm\"\u003eOvercurrent Protection\u003c\/td\u003e\n\u003ctd data-start=\"2542\" data-end=\"2573\" data-col-size=\"sm\"\u003eplus minus 28 mA continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2574\" data-end=\"2616\"\u003e\n\u003ctd data-start=\"2574\" data-end=\"2585\" data-col-size=\"sm\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd data-start=\"2585\" data-end=\"2616\" data-col-size=\"sm\"\u003eup to 0.05 percent of range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2617\" data-end=\"2658\"\u003e\n\u003ctd data-start=\"2617\" data-end=\"2641\" data-col-size=\"sm\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd data-start=\"2641\" data-end=\"2658\" data-col-size=\"sm\"\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2659\" data-end=\"2696\"\u003e\n\u003ctd data-start=\"2659\" data-end=\"2672\" data-col-size=\"sm\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-start=\"2672\" data-end=\"2696\" data-col-size=\"sm\"\u003eStandard RX3i module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2697\" data-end=\"2713\"\u003e\n\u003ctd data-start=\"2697\" data-end=\"2706\" data-col-size=\"sm\"\u003eOrigin\u003c\/td\u003e\n\u003ctd data-start=\"2706\" data-end=\"2713\" data-col-size=\"sm\"\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2714\" data-end=\"2741\"\u003e\n\u003ctd data-start=\"2714\" data-end=\"2723\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"2723\" data-end=\"2741\" data-col-size=\"sm\"\u003eApprox 0.32 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-section-id=\"1uce968\" data-start=\"2743\" data-end=\"2761\"\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp data-start=\"2763\" data-end=\"2948\"\u003e\u003cstrong data-start=\"2763\" data-end=\"2828\"\u003eDoes IC695ALG626 support HART communication on every channel?\u003c\/strong\u003e\u003cbr data-start=\"2828\" data-end=\"2831\"\u003eYes. The module supports HART communication through four internal modems. Channels are multiplexed into modem groups.\u003c\/p\u003e\n\u003cp data-start=\"2950\" data-end=\"3098\"\u003e\u003cstrong data-start=\"2950\" data-end=\"2992\"\u003eWhich CPU is required for this module?\u003c\/strong\u003e\u003cbr data-start=\"2992\" data-end=\"2995\"\u003eRX3i CPU firmware version 3.5 or later is required. Machine Edition 5.5 or newer configures the module.\u003c\/p\u003e\n\u003cp data-start=\"3100\" data-end=\"3235\"\u003e\u003cstrong data-start=\"3100\" data-end=\"3149\"\u003eCan the module work with differential inputs?\u003c\/strong\u003e\u003cbr data-start=\"3149\" data-end=\"3152\"\u003eYes. Configure the module for 8 differential inputs through software configuration.\u003c\/p\u003e\n\u003cp data-start=\"3237\" data-end=\"3365\"\u003e\u003cstrong data-start=\"3237\" data-end=\"3277\"\u003eWhat terminal blocks are compatible?\u003c\/strong\u003e\u003cbr data-start=\"3277\" data-end=\"3280\"\u003eIC694TBB032, IC694TBB132, IC694TBS032, and IC694TBS132 terminal blocks are supported.\u003c\/p\u003e\n\u003chr data-start=\"3367\" data-end=\"3370\"\u003e\n\u003ch3 data-section-id=\"fu9pxb\" data-start=\"3372\" data-end=\"3408\"\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp data-start=\"3410\" data-end=\"3526\"\u003eUse shielded twisted pair wiring for 4 to 20 mA HART loops. Ground the shield at one end only to avoid ground loops.\u003c\/p\u003e\n\u003cp data-start=\"3528\" data-end=\"3644\"\u003eDistribute HART devices across channel groups 1, 5, 9, and 13 to minimize update time. This reduces multiplex delay.\u003c\/p\u003e\n\u003cp data-start=\"3646\" data-end=\"3752\"\u003eInstall the module in slots with adequate airflow. High channel count current mode increases thermal load.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52695422665067,"sku":"IC695ALG626","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/general-electric-ic695alg626-analog-input-hart-module-egpeer2sspd_912f0a65-4194-4167-a679-9375a8a9cefb.jpg?v=1766135475","url":"https:\/\/www.plcprotech.com\/fr\/products\/ic695alg626-ge-fanuc-pacsystems-rx3i-analog-input-module-with-hart","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}