{"product_id":"is220ppros1b-general-electric-mark-vie-backup-turbine-protection-i-o-module","title":"Module E\/S de protection turbine de secours GE Mark VIe IS220PPROS1B","description":"\u003ch3\u003eSystem Subsystem \u0026amp; Critical Operational Value\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS220PPROS1B (IS220PPROS1B)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-reliability, safety-critical backup turbine protection I\/O module designed for the General Electric Mark VIe control platform. This distributed processing block interfaces directly with dedicated terminal boards to execute independent, hardware-based emergency trip functions, mechanical overspeed detection, and emergency deceleration subroutines. Operating within high-risk utility sectors—such as large-scale thermal power plants, nuclear generation facilities, and petrochemical gas-cracking complexes—the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS220PPROS1B (IS220PPROS1B)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides an autonomous layer of protection separate from the primary control processors. By maintaining a localized triple modular redundant (TMR) routing structure across its terminal boards, the module monitors critical speed sensors and trip interlocks simultaneously. This fast-acting logic ensures instantaneous turbine trips during hazardous overspeed conditions, protecting multi-million dollar rotating assets and eliminating unexpected operational downtime.\u003c\/p\u003e\n\u003ch3\u003eHardware Safety Architecture \u0026amp; Terminal Interfacing\u003c\/h3\u003e\n\u003cp\u003eThe physical and electronic design of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS220PPROS1B\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule centers on fault-tolerant safety monitoring and ruggedized industrial compliance.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eComprehensive Terminal Board Pairing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEngineered for direct mounting onto specialized accessory terminal boards, supporting both compact, simplex setups and full TMR configuration blocks including the SPRO, TPRO, and TREA series.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual Ethernet Connectivity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIncorporates twin IONet ports to deliver redundant, deterministic Ethernet communications, passing diagnostic flags to the supervisory Mark VIe control network without dropping local safety loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHazardous Area Certification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBuilt to withstand harsh operational deployments, holding global Class I, Division 2 and ATEX Zone 2 flameproof ratings to allow safe positioning closer to the physical turbine enclosure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical, Thermal \u0026amp; Compliance Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetailed Technical Specification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIS220PPROS1B\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGeneral Electric (GE \/ Mark VIe Series)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Function\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBackup Turbine Protection I\/O Processor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompatible Terminal Boards\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIS200SPROH1A, IS200SPROH2A, IS200TPROH1C, IS200TPROH2C, IS200TPROS1C, IS200TPROS2C, IS200TREAH1A, IS200TREAH3A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30 to +65 deg C (-22 to +149 deg F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.5 W Typical (Sourced via dual 28 VDC input rails)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHazardous Locations Class\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eClass I, Division 2, Groups A, B, C, D, T4 \/ Zone 2, Group IIC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eATEX Rating Standards\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEx nA IIC T4 Gc (ULDEMKO13ATEX1214780X)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eGeneral Safety Listings\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUL508 Ed.17, CSA-C22.2 No.142-M1987, ANSI\/ISA-12.12.01-2015\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eExplosive Atmosphere Norms\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUL60079-15 Ed.3, EN60079-0:2012, EN60079-15:2010\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEstimated Package Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.2 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eField Service FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhich accessory terminal board must be selected for standard emergency trip relay interfacing?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe choice depends on your architecture. For typical turbine emergency trip relay protection systems, the module is paired with the IS200TPRO or IS200TREA boards. The TPRO board interfaces directly with passive magnetic speed pickups and handles emergency deceleration contacts, whereas the TREA provides specialized trip execution pathways for turbine lubrication and hydraulic line solenoids.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat actions should be taken if an ATEX Zone 2 thermal alarm flag is triggered?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eVerify that the ambient temperature surrounding the module housing has not exceeded the strict upper ceiling of +65 deg C. Ensure that the internal cabinet ventilation fans are functional, that the convective airflow louvers are free from obstruction, and that nearby heat-radiating components maintain adequate structural clearance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the firmware synchronization managed when swapping out an old module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Mark VIe system supports automated parameter downloading. When an Original New IS220PPROS1B module is secured onto the active terminal board and linked to the IONet network, the master controller identifies the device hardware address and automatically pushes the designated firmware revision and safety profile parameters to the card.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Board Mechanical Coupling:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen joining the IS220PPROS1B module to its associated terminal board, align the plastic guide pins carefully before seating the high-density d-sub connectors. Fasten the integral retaining screws to a standard torque specification of 1.2 Nm. Loose mounting screws degrade the structural bond, resulting in intermittent ground references and unwanted trip alarms under high turbine vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShield Integrity and High-Frequency Grounding:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAll passive speed pickup and speed sensor lines routing into the TPRO or SPRO board terminals must use individual, high-density braided shielding. Connect the cable shield only at the terminal board ground bar point. Incorrectly grounding both ends of the shield creates structural ground loops, injecting electromagnetic interference that can cause false overspeed readings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Enclosure Management for Explosive Areas:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTo maintain the validity of the ANSI\/ISA-12.12.01-2015 and EN60079-15 toolless certifications, this I\/O module must reside entirely within an IP54 or greater tool-secured industrial enclosure. This step protects the circuit connections from airborne chemical corrosives, heavy dust buildup, and humidity levels exceeding the non-condensing boundaries.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52695408378219,"sku":"IS220PPROS1B","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/general-electric-is220ppros1b-emergency-turbine-protection-i-o-pack-zi3byazo4zb_f4b941c4-25b6-4fbc-9823-079ec4c9dce8.jpg?v=1766134968","url":"https:\/\/www.plcprotech.com\/fr\/products\/is220ppros1b-general-electric-mark-vie-backup-turbine-protection-i-o-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}