{"product_id":"is420eswah3a-ge-mark-vie-mark-vies-industrial-ethernet-switch","title":"Commutateur Ethernet industriel GE Mark VIe Mark VIeS IS420ESWAH3A","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS420ESWAH3A \u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a safety-critical, high-availability Industrial Ethernet Switch custom-engineered by General Electric for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMark VIe\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMark VIeS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ereal-time control system architectures. Functioning under the structural abbreviation\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eESWA\u003c\/strong\u003e, this hardware unit serves as the deterministic communication foundation for the internal Internal Optical Network (IONet). Critical industrial complexes—including combined-cycle gas turbine power stations, high-pressure petrochemical refineries, and deep-pit mining operations—deploy this specialized switch to maintain real-time data flow between control racks, I\/O packs, and emergency shutdown controllers. Featuring an all-copper interface topology designed to handle continuous streams of multicast and broadcast packets without dropping data frames, the switch establishes reliable network synchronization. This eliminates packet collision latency and prevents communication-related false system trips, protecting massive gas turbines and mitigating catastrophic facility downtime.\u003c\/p\u003e\n\u003ch3\u003eArchitectural Subsystems \u0026amp; Network Capabilities\u003c\/h3\u003e\n\u003cp\u003eThe structural layout and internal engineering specifications of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS420ESWAH3A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIONet communication device dictate its performance parameters across industrial networks.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAll-Copper Network Topology:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOutfitted with eight high-density 10\/100Base-TX copper RJ45 ports. Differing from alternative ESWA variants that integrate fiber optic transceivers, the H3A revision is uniquely engineered with zero fiber components to minimize network conversion latency in localized copper backplane segments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeterministic Store-and-Forward Framework:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIncorporates a specialized store-and-forward switching architecture designed to buffer continuous broadcast or multicast packet bursts safely. This layout stabilizes latency factors and ensures high data integrity under heavy automation traffic loads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDynamic Media Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrates comprehensive compatibility parameters with IEEE 802.3, 802.3u, and 802.3x interface rules, including active auto-sensing capabilities via standard HP-MDIX crossovers to eliminate specialized patch cable dependencies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eG3 Environmental Hardening:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCertified with full G3-compliant conformal PCB coating layers, shielding internal microprocessor tracks and memory spaces from airborne chemical contaminants, trace humidity, and corrosive gases.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Parameters \u0026amp; Performance Matrix\u003c\/h3\u003e\n\u003ctable style=\"width: 100%;\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd style=\"width: 36.8579%;\"\u003e\u003cstrong\u003eHardware Parameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.7811%;\"\u003e\u003cstrong\u003eTechnical Specification Standard\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.8579%;\"\u003e\u003cspan\u003e\u003cstrong\u003eModel Designation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.7811%;\"\u003e\u003cspan\u003eIS420ESWAH3A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.8579%;\"\u003e\u003cspan\u003e\u003cstrong\u003eBrand Manufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.7811%;\"\u003e\u003cspan\u003eGE Gas Power (General Electric)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.8579%;\"\u003e\u003cspan\u003e\u003cstrong\u003eControl System Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.7811%;\"\u003e\u003cspan\u003ePACSystems \/ Speedtronic Mark VIe \u0026amp; Mark VIeS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.8579%;\"\u003e\u003cspan\u003e\u003cstrong\u003eFunctional Acronym\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.7811%;\"\u003e\u003cspan\u003eESWA (Group Three Variant)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.8579%;\"\u003e\u003cspan\u003e\u003cstrong\u003eDevice Classification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.7811%;\"\u003e\u003cspan\u003eConformal Coated 8-Port Industrial Ethernet Switch\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.8579%;\"\u003e\u003cspan\u003e\u003cstrong\u003eCopper Port Configuration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.7811%;\"\u003e\u003cspan\u003eEight 10\/100Base-TX RJ45 Interfaces\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.8579%;\"\u003e\u003cspan\u003e\u003cstrong\u003eFiber Port Components\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.7811%;\"\u003e\u003cspan\u003eZero Fiber Ports\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.8579%;\"\u003e\u003cspan\u003e\u003cstrong\u003eNetwork Switching Architecture\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.7811%;\"\u003e\u003cspan\u003eStore-and-Forward with Inrush Current Limiting\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.8579%;\"\u003e\u003cspan\u003e\u003cstrong\u003eOperational Input Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.7811%;\"\u003e\u003cspan\u003e24 \/ 28 VDC Regulated Feed Lines\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.8579%;\"\u003e\u003cspan\u003e\u003cstrong\u003eEnvironmental Protection Class\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.7811%;\"\u003e\u003cspan\u003eISA G3 Harsh Environment Compliance\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.8579%;\"\u003e\u003cspan\u003e\u003cstrong\u003ePhysical Dimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.7811%;\"\u003e\u003cspan\u003e13.8 cm H x 8.6 cm W x 5.6 cm D\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.8579%;\"\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature Window\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.7811%;\"\u003e\u003cspan\u003e-30 to +65 deg C Ambient Range\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.8579%;\"\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature Limits\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.7811%;\"\u003e\u003cspan\u003e-40 to +85 deg C (-40 to +185 deg F) Maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 36.8579%;\"\u003e\u003cspan\u003e\u003cstrong\u003ePerpendicular Mounting Clip\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.7811%;\"\u003e\u003cspan\u003ePart Number 259B2451BVP2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eNetwork Operations \u0026amp; Hardware Lifecycle FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat primary design detail distinguishes the Group Three IS420ESWAH3A from other ESWA switches?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe H3A revision represents the unique Group Three configuration within the GE ESWA product family characterized by having zero fiber optic ports. While earlier models like the IS420ESWAH1A incorporate fiber interfaces for long-distance network extensions, the H3A relies entirely on eight 10\/100Base-TX copper ports to optimize localized node distribution.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the IS420ESWAH3A handle packet buffering during periods of heavy multicast network traffic?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe switch uses an architecture optimized for continuous broadcast or multicast streams. It buffers one incoming packet stream per port at a time while staging remaining data sequences for immediate subsequent transmission. System designers must configure network traffic patterns to adhere to a one packet per port rule to maximize real-time efficiency.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this switch compatible with standard functional safety architectures in Mark VIeS systems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The IS420ESWAH3A is officially certified and fully G3 compliant for deployment within Mark VIeS functional safety loops. Its hardened components, predictable store-and-forward latency metrics, and electrical noise rejection ensure safe processing of emergency shutdown telemetry.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Engineering \u0026amp; Installation Protocol\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePerpendicular Mounting and Rail Retention:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSecure the switch body onto the standard internal cabinet DIN rail using the official 259B2451BVP2 perpendicular mounting clip. Ensure the metal spring clip engages the rail flange completely until a distinct click is felt. Under continuous machine deck vibration profiles typical near high-capacity gas turbine packages, unverified or loose mounting clips can degrade structural grounding tracks and cause intermittent hardware power failures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDC Voltage Feed and Inrush Current Management:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRoute the dual-redundant 24\/28 VDC electrical power lines through independent low-impedance copper terminal channels. The internal switch circuitry features automated inrush current limiting mechanisms to guard internal power rails during power transitions. Maintain a stable ambient terminal torque profile of 0.5 N-m (4.4 inch-lbs) on the power connector block to prevent localized resistive heating and voltage drop conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConformal Protection and Environmental Hardening Constraints:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAlthough the switch features standard G3 conformal coating protection against humidity and gaseous chemical corrosion, you must maintain ambient thermal conditions within the designated operating window of -30 to +65 deg C. Do not obstruct the integrated ventilation slots located on the top and bottom of the module enclosure casing. Ensure a minimum clearance gap of 5 cm around the perimeter of the housing to facilitate passive thermal dissipation and avoid thermal hot spots.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52695407853931,"sku":"IS420ESWAH3A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/general-electric-is420eswah3a-ionet-ethernet-switch-h35chzdnupv_aa386229-2026-4da4-97ec-d0a3e41527e4.jpg?v=1766134952","url":"https:\/\/www.plcprotech.com\/fr\/products\/is420eswah3a-ge-mark-vie-mark-vies-industrial-ethernet-switch","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}