{"product_id":"kl2761-0011-beckhoff-1-channel-universal-dimmer-bus-terminal","title":"KL2761-0011 BECKHOFF Terminal bus Variateur universel 1 canal","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKL2761-0011 (KL 2761-0011)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance 1-channel universal dimmer terminal designed for the precise control of AC lighting and power loads up to 600 VA (W). Operating at a nominal 230 V AC, this Bus Terminal integrates fieldbus functionality directly into lighting control, allowing for seamless automation of industrial illumination and power levels. In sectors such as commercial building automation, stage lighting control, and specialized agricultural climate systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKL2761-0011\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis essential for managing ohmic, inductive, or capacitive loads. With its automatic load detection feature and advanced phase control technology, it optimizes power delivery while ensuring compatibility with various lamp types and electrical actuators, effectively reducing energy consumption and extending equipment life.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKL2761-0011\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ehardware is engineered for industrial-grade power management using a 4-wire connection technology. It utilizes phase control (dimming) with a 1% resolution, allowing for smooth transitions in brightness or power output. The module is rated for a maximum output current of 2.7 A and is designed to be short-circuit proof, with a peak short-circuit current handling of 20 to 40 A. One of its standout safety features is the high dielectric strength, offering electrical isolation of up to 3750 V AC (for 1 minute) between the power stage and the control logic. The terminal automatically detects the connected load type upon startup, adjusting its internal firing angle to ensure stable operation regardless of whether the load is a resistive heater, an inductive transformer, or a capacitive electronic ballast.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eKL2761-0011\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBECKHOFF\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGermany\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNominal Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e230 V AC (50 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Output\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e600 VA (W)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMax. 2.7 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eControl Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePhase control (Dimmer)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 %\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLoad Types\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOhmic, Inductive, Capacitive (not mixed), Lamp load\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical Isolation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3750 V AC (1 min) \/ 500 V (K-bus to field)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCurrent Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTyp. 95 mA (K-bus)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBit Width\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOutput: 1 x 16 bit data\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to +55 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e60 g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the KL2761-0011 support mixed loads on a single channel?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the module is designed for ohmic, inductive, or capacitive loads, but they must\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003enot\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebe mixed. Mixing load types (e.g., connecting a transformer and a resistor in parallel) can interfere with the automatic load detection and phase control logic, potentially leading to unstable dimming or hardware failure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if a short circuit occurs at the output?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKL2761-0011\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis equipped with short-circuit protection capable of handling 20 to 40 A during a fault event. The module will shut down the output to protect the internal power electronics. After the fault is cleared, the system status should be checked via the optional 8-bit status byte in the process image before restarting.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs there a leakage current when the dimmer is in the \"OFF\" state?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, in the OFF state, there is a minor leakage current of less than 1 mA. While this is standard for electronic dimmers, it is an important consideration when using high-efficiency LED lamps that may flicker or glow slightly at very low current levels.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eAutomatic Load Detection and Initialization:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKL2761-0011\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis powered up, it performs a brief initialization to detect the load characteristic. Ensure that the load is fully connected and stable during the power-on sequence. For capacitive loads (like electronic ballasts) or inductive loads (like conventional transformers), the terminal will automatically select between leading-edge or trailing-edge phase control to prevent voltage spikes or current surges.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Management and Installation Position:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eManaging 600 VA in a compact Bus Terminal housing generates heat. The module is rated for 0 to +55 deg C, but this assumes standard horizontal mounting on a 35 mm DIN rail with adequate ventilation. If multiple\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKL2761-0011\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eunits are mounted side-by-side and operated at full load (2.7 A), it is highly recommended to maintain a minimum clearance of 12 mm (one empty terminal width) between modules or use active cabinet cooling to prevent thermal shutdown.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWiring and Safety Compliance:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUse the 4-wire connection technology as specified in the Beckhoff wiring diagram to ensure proper grounding and neutral referencing. All conductors should be stripped to 8–9 mm before being inserted into the spring-actuated terminals. Given the 230 V AC mains voltage, ensure all installation work is performed in a de-energized state. The high 3750 V AC isolation rating ensures the K-bus and CPU remain safe even in the event of a catastrophic field-side failure.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106650087787,"sku":"KL2761-0011","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/kl2761-0011-o5a5yn42pg1.png?v=1776245144","url":"https:\/\/www.plcprotech.com\/fr\/products\/kl2761-0011-beckhoff-1-channel-universal-dimmer-bus-terminal","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}