{"product_id":"kl9560-beckhoff-power-supply-unit-terminal-24-vdc-24-vdc","title":"KL9560 | BECKHOFF | Unité d'alimentation terminale 24 VCC \/ 24 VCC","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKL9560 (KL9560)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized power supply unit terminal designed to provide an isolated 24 VDC output from a standard 24 VDC input within the Beckhoff Bus Terminal system. Unlike standard power feed terminals that simply pass through the field voltage, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKL9560\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eincorporates a high-grade DC\/DC converter to create a galvanically isolated voltage source. This module is essential for powering sensitive analog sensors, high-precision measuring transducers, or specialized electronics that require a \"clean\" voltage supply, free from the electrical noise and ground loops common on the main industrial power contacts. With a 1,500 V AC insulation voltage between the field and K-bus, it ensures maximum protection for the central control logic.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe hardware architecture of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKL9560\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis optimized for stability and diagnostic visibility. It provides an output current of up to 0.1 A, featuring full short-circuit protection with an automatic restart capability once the fault is cleared. A key technical advantage is the integration of diagnostics into the process image, allowing the controller to monitor the health of the isolated supply in real-time. The unit achieves approximately 85% efficiency and is housed in a compact 12 mm polycarbonate shell. It is certified for demanding marine applications (DNV GL) and hazardous areas (ATEX), making it a reliable choice for offshore platforms and chemical processing environments where signal integrity is a safety requirement.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eKL9560\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBECKHOFF\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGermany\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC (-15 percent \/ +20 percent)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC (-15 percent \/ +5 percent)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt;= 0.1 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eapprox. 85 percent\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInsulation Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1,500 VAC (field\/K-bus), 500 VAC (input\/output)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShort-circuit Proof\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes, with automatic restart\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes (available in process image)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 mm x 100 mm x 68 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to +55 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE, UL, ATEX, DNV GL\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhy use the KL9560 instead of a standard power feed terminal?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStandard power feed terminals (like the KL9100) share a common ground and electrical potential with all other modules on the power rail. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKL9560\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides a separate, isolated 24 VDC circuit. This is critical when using sensors that are sensitive to ground potential differences or high-frequency switching noise from nearby motor drives.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if the 0.1 A output current is exceeded?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe terminal is short-circuit proof. If the current reaches approximately 0.15 A, the module will shut down to protect its internal DC\/DC converter. Once the overload or short circuit is removed, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKL9560\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewill automatically restart and restore the 24 VDC output.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I monitor the power status from my PLC?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKL9560\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides diagnostic data directly in the process image. This allows the PLC to detect a loss of output voltage or a fault condition and trigger an alarm or safe-state routine.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLoad Calculation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the total current draw of the connected devices does not exceed 100 mA (0.1 A). This terminal is designed for signal-level power (sensors, encoders, small relays) rather than high-power actuators or valves.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding for Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo maintain the benefit of the 500 V galvanic isolation, do\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003enot\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebridge the output 0V of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKL9560\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eback to the main system 0V. Doing so would negate the electrical isolation and could reintroduce the noise the terminal is designed to block.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHazardous Area Compliance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor ATEX Zone 2 installations (Ex nA), ensure the module is installed in an IP54-rated enclosure. Check that all terminal connections are tightened and that ferrules are used for stranded wires to prevent sparking due to vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring Precision:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse the spring-actuated terminals for a vibration-proof connection. A stripping length of 8 to 9 mm is required. For analog applications, use shielded cables for the output voltage and ground the shield at a single point to ensure the highest signal-to-noise ratio.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106668208491,"sku":"KL9560","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/kl9560-khklnn3x4ab.png?v=1776245232","url":"https:\/\/www.plcprotech.com\/fr\/products\/kl9560-beckhoff-power-supply-unit-terminal-24-vdc-24-vdc","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}