{"product_id":"km1002-0002-beckhoff-bus-terminal-module-16-channel-digital-input","title":"KM1002-0002 BECKHOFF Module bornier Bus Entrée numérique 16 canaux","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKM1002-0002 (KM10020002)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density Bus Terminal module designed to maximize space efficiency within the Beckhoff I\/O system. By consolidating 16 digital inputs into a compact 26.5 mm housing, this module allows for a significant reduction in control cabinet size while maintaining high-performance signal processing. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKM1002-0002\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003especifically features 1-wire connection technology with integrated status LEDs, providing immediate visual diagnostics for each of its 16 channels. Engineered for reliability in industrial automation sectors such as building management, logistics, and general machine construction, it ensures the seamless transmission of 24 VDC control signals to the higher-level K-bus with 500 V electrical isolation.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe KM1002 series utilizes a standardized suffix logic to define the wiring interface and diagnostic features of the module:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-0000:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard 16-channel digital input module supplied without the pluggable wiring connectors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-0001:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eVersion equipped with 1-wire pluggable connectors for basic signal termination.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-0002:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eVersion equipped with 1-wire pluggable connectors and integrated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ediagnostic LEDs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor channel-specific status monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-0004:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-density version featuring 3-wire connectors and LEDs, allowing for direct sensor power distribution (VCC\/GND\/Signal) at the terminal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eKM1002-0002\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBECKHOFF\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGermany\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of Inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 (arranged in 2 x 8 blocks)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNominal Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC (-15 percent \/ +20 percent)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnection Technology\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1-wire pluggable connector\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStatus Indicators\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 individual LEDs (Signal\/Status)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Filter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003etyp. 3.0 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\"1\" Signal Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15 to 30 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\"0\" Signal Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-3 to +5 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCurrent Consumption (K-bus)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003etyp. 3 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical Isolation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e500 V (K-bus \/ Field Potential)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions (W x H x D)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e26.5 mm x 100 mm x 71 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to +55 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eapprox. 90 g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the KM1002-0002 support 3-wire sensor connections directly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKM1002-0002\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed for 1-wire connection technology, meaning it receives the signal wire from the sensor. For sensors requiring 24 VDC and 0V power directly from the module, the KM1002-0004 variant (3-wire) is the appropriate choice. With the -0002, common power distribution must be handled via separate potential distribution terminals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module be used in systems experiencing high mechanical stress?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The module conforms to EN 60068-2-6 and EN 60068-2-27 standards for vibration and shock resistance. The pluggable wiring level is secured with a locking mechanism, and the module itself attaches to the 35 mm DIN rail with a robust double slot and key connection, ensuring stability side-by-side with other terminals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the function of the 3.0 ms input filter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 3.0 ms filter is an integrated hardware debounce mechanism. It prevents the PLC from registering \"false\" signals caused by mechanical contact bounce or transient electromagnetic noise on the signal lines, ensuring that only valid state changes are processed by the automation unit.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring Efficiency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe pluggable connector system allows for the wiring harness to be pre-assembled or replaced as a single unit. When inserting wires (0.08 to 1.5 mm squared), ensure a stripping length of exactly 8 mm to guarantee a secure gas-tight connection within the spring-actuated terminal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStatus Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse the integrated LEDs to simplify commissioning. A lit LED indicates a \"1\" signal (High) at the input. If a sensor is triggered but the LED remains dark, check the field-side voltage or the common ground (0V) connection, as the KM1002-0002 requires a shared reference potential with the field sensors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePotential Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNote that this module provides 500 V isolation between the K-bus (logic side) and the field potential. However, there are no power contacts on the side of the housing. The field power for the inputs must be supplied through the front-facing connectors to ensure the inputs are correctly energized.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106657263979,"sku":"KM1002-0002","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/KM1002-0002-ofzdjhmwf5h.png?v=1776245234","url":"https:\/\/www.plcprotech.com\/fr\/products\/km1002-0002-beckhoff-bus-terminal-module-16-channel-digital-input","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}