{"product_id":"lenze-e82ev751-2b-8200-series-variable-frequency-drive","title":"Variateur de fréquence série 8200 Lenze E82EV751_2B","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eProviding precise speed and torque regulation for industrial three-phase AC induction motors, the \u003cstrong\u003eLenze E82EV751_2B\u003c\/strong\u003e serves as a reliable vector-controlled variable frequency drive within the legacy \u003cstrong\u003e8200 Vector\u003c\/strong\u003e series. This compact drive module is engineered for space-saving control cabinet installation, delivering robust performance in demanding automation architectures. It supports both single-phase and three-phase mains connections, making it highly adaptable to various field power configurations.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.25rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible Input Configuration:\u003c\/strong\u003e Supports 1-phase or 3-phase AC 230\/240 V input voltages.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Frequency Output:\u003c\/strong\u003e Delivers an adjustable output frequency from 0 to 650 Hz, ideal for high-speed spindle operations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModular Communication:\u003c\/strong\u003e Equipped with an integrated slot for pluggable fieldbus modules (CAN, PROFIBUS, or LECOM).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRobust Protection:\u003c\/strong\u003e Built-in motor overload, short-circuit, earth-fault, and overvoltage monitoring circuits.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompact Form Factor:\u003c\/strong\u003e Optimized footprint designed for space-restricted control panels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.25rem;\"\u003e\n  \u003cli\u003eConveyor and material handling systems requiring controlled acceleration and deceleration.\u003c\/li\u003e\n  \u003cli\u003eIndustrial pumps, fans, and ventilation systems.\u003c\/li\u003e\n  \u003cli\u003ePackaging machinery and automated assembly lines.\u003c\/li\u003e\n  \u003cli\u003eMachine tool auxiliary drives and high-speed spindle applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eLenze\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eE82EV751_2B (E82EV751K2B)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProduct Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e8200 Vector\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eInput Voltage Phase\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1(3)\/PE AC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eInput Voltage Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e230 \/ 240 V\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eInput Current\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e9.0 A (1-phase) \/ 5.2 A (3-phase)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eInput Frequency\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e50 \/ 60 Hz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOutput Voltage Phase\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e3\/PE AC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOutput Voltage Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0 to 230 \/ 240 V\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOutput Current\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e4.0 A\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOutput Power Rating\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0.75 kW (1.0 HP)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOutput Frequency Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0 to 650 Hz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProduct Lifecycle Phase\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003ePhase-Out (Legacy)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e24.0 x 16.2 x 30.6 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eNet Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0.74 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1.20 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e85044086\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eTerminal \/ Port\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eFunction \/ Circuit Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eL1, N\/L2, L3\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eMains supply input connections (Single-phase or Three-phase)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eU, V, W\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eMotor output connection terminals\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePE\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eProtective Earth ground connections\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eAIF Slot\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eAutomation Interface for keypad (EMZ8201BB) or communication modules (EMF2102IB)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe E82EV751_2B is often designated in PLM systems under the code \u003cstrong\u003eE82EV751K2B\u003c\/strong\u003e. It is fully compatible with the Lenze EMZ8201BB parameterization keypad and the EMF2102IB LECOM-A (RS232\/RS485) communication module. When replacing an older 8200 Standard series drive, note that the 8200 Vector series uses a different parameter structure, requiring a manual transfer of settings rather than a direct copy-paste via older software versions.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eAs a legacy phase-out model, thermal management is critical to preserving the unit's internal DC-bus capacitors. Ensure a minimum vertical mounting clearance of 100 mm above and below the drive. Continuous operation at the maximum 4.0 A output current in ambient temperatures exceeding 40 degC will accelerate capacitor degradation; external cabinet cooling or derating is highly recommended in these environments.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eAlways use low-capacitance, shielded motor cables to minimize high-frequency leakage currents. The cable shield must be grounded over a large surface area directly to the conductive mounting plate using grounding clamps. To prevent electromagnetic interference, never route control cables parallel to motor power cables; maintain a minimum physical separation of 10 cm.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e Ensure all input power sources are completely de-energized and locked out before performing any wiring or maintenance. Wait at least 5 minutes after disconnecting the power supply to allow the internal DC-bus capacitors to fully discharge to safe voltage levels (\u0026lt; 50 VDC).\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eMount the drive vertically on a flat, vibration-free conductive mounting plate inside the control cabinet to ensure proper heat dissipation and grounding.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eConnect the protective earth (PE) conductor to the designated ground terminal before making any other electrical connections.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eWire the AC mains input to terminals L1\/N (for single-phase) or L1\/L2\/L3 (for three-phase) and the motor output to terminals U\/V\/W.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eInsert the required control module or keypad into the front AIF slot, ensuring it clicks securely into place before applying power.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105047961963,"sku":"E82EV751_2B","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/e82ev751-2b-lfwh0rpeucr.png?v=1776235890","url":"https:\/\/www.plcprotech.com\/fr\/products\/lenze-e82ev751-2b-8200-series-variable-frequency-drive","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}