{"product_id":"lenze-e82zafd-8200-series-canopen-function-module","title":"Module fonction Lenze série 8200 E82ZAFD","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eIntegrating seamlessly into the 8200 vector frequency inverter range, the \u003cstrong\u003eLenze E82ZAFD\u003c\/strong\u003e serves as a dedicated CANopen communication interface designed to facilitate high-speed, deterministic data exchange across industrial automation networks. This module mounts directly onto the front-facing Application Interface (AIF) slot of the drive, eliminating the need for external mounting hardware or additional control wiring.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eDirect integration into the Lenze 8200 vector drive AIF slot.\u003c\/li\u003e\n  \u003cli\u003eFull compliance with the CANopen communication protocol according to DS301 profile specifications.\u003c\/li\u003e\n  \u003cli\u003eConfigurable baud rates up to 1 Mbps, adjustable via integrated DIP switches or internal drive parameter codes.\u003c\/li\u003e\n  \u003cli\u003eElectrical isolation between the CAN bus network medium and the internal drive control electronics to prevent ground loops.\u003c\/li\u003e\n  \u003cli\u003eOnboard diagnostic LEDs providing real-time visual feedback on network status and module power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eDecentralized drive control architectures in manufacturing and assembly lines.\u003c\/li\u003e\n  \u003cli\u003eMulti-axis synchronized motion control applications.\u003c\/li\u003e\n  \u003cli\u003eConveyor systems, material handling, and packaging machinery.\u003c\/li\u003e\n  \u003cli\u003eIntegration of legacy Lenze 8200 vector drives into modern CANopen master control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; width: 40%;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eLenze\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eE82ZAFD\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eSeries\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e8200-series\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eModule Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eFunction Module \/ Communication Interface\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCommunication Protocol\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eCANopen (DS301)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eBaud Rate Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e20 kbps to 1 Mbps\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eNode Address Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1 to 63 (configurable via DIP switches or codes)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eInterface Slot Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eAIF (Application Interface)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eGermany\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e0.02 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e80 mm x 50 mm x 30 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold; width: 40%;\"\u003eTerminal \/ Pin\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold;\"\u003eFunction \/ Circuit Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCAN_H\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eCAN High Signal Line\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCAN_L\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eCAN Low Signal Line\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eGND\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eCAN Reference Ground (Isolated)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe E82ZAFD is backwards compatible with all standard Lenze 8200 vector frequency inverters ranging from 0.25 kW to 90 kW. It directly replaces non-isolated CAN communication modules. Note that depending on the firmware revision of your 8200 vector drive (specifically revisions below V2.0), certain advanced CANopen monitoring objects may have limited access, requiring configuration via the standard drive keypad parameter codes.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eA common point of failure during commissioning is the omission of the physical 120-ohm termination resistor. The E82ZAFD does not feature an internal software-switchable termination resistor; therefore, a physical 120-ohm resistor must be wired externally across the CAN_H and CAN_L terminals at the first and last physical nodes of the bus. Operating without proper termination leads to intermittent frame errors, packet loss, and drive communication faults (typically triggering a CE0 or CE3 fault on the inverter).\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eTo ensure robust noise immunity in high-EMI environments, use only high-quality shielded twisted-pair (STP) cabling specified for CAN networks. Route the communication cable at least 20 cm away from high-voltage motor output cables and AC supply lines. The cable shield must be grounded at a single point (typically at the master controller) to prevent ground loops from corrupting the differential communication signals.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eBefore installing or removing the E82ZAFD module, completely de-energize the main AC supply to the Lenze 8200 vector inverter. Wait at least 5 minutes for the internal DC-bus capacitors to fully discharge to safe voltage levels. Verify zero voltage at the power terminals before proceeding. Hot-plugging the module will cause permanent damage to the AIF interface and the drive's control board.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 2px;\"\u003eEnsure the inverter is completely powered down and the DC-bus discharge time has elapsed.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 2px;\"\u003eSet the required node address and baud rate using the DIP switches located on the side of the E82ZAFD module before inserting it into the slot.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 2px;\"\u003eAlign the module carefully with the AIF slot on the front of the 8200 vector inverter and press firmly until the retaining clips click into place.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 2px;\"\u003eConnect the CAN bus lines (CAN_H, CAN_L, and GND) to the pluggable terminal block, ensuring correct polarity and shielding termination.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105049403755,"sku":"E82ZAFD","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/e82zafd-ct4hzktvsne.png?v=1776235984","url":"https:\/\/www.plcprotech.com\/fr\/products\/lenze-e82zafd-8200-series-canopen-function-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}