{"product_id":"lenze-evs9330-ep-9300-series-servo-position-controller","title":"Lenze EVS9330-EP Contrôleur de position servo série 9300","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eLenze EVS9330-EP (EVS9330-EP)\u003c\/strong\u003e is a high-capacity servo position controller representing the apex of the 9300-Series power range. Rated for 45.0 kW, this unit is engineered for heavy-duty motion control tasks that demand high torque and exact synchronization. Its advanced positioning logic makes it an indispensable component in large-scale industrial machinery, such as paper processing lines, heavy rolling mills, and high-inertia manufacturing platforms. By centralizing motion control and drive regulation, the EVS9330-EP provides the precision necessary to maintain operational throughput while minimizing mechanical fatigue on drivetrain components.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe EVS9330-EP is constructed to manage significant power loads with extreme stability, featuring integrated intelligence for complex motion profiling.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Positioning Control:\u003c\/strong\u003e The drive executes high-speed position loops internally, allowing for precise control of axis movement without requiring high-latency communication with an external motion controller.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Density:\u003c\/strong\u003e At 45.0 kW, the hardware utilizes sophisticated heat management and robust IGBT power stages to ensure long-term reliability under continuous, high-load industrial duty cycles.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular Architecture:\u003c\/strong\u003e Designed as part of the 9300-Series, it is compatible with a wide array of plug-in feedback and communication modules, enabling the drive to adapt to various fieldbus environments (e.g., Profibus, CANopen, or Ethernet-based protocols).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMonitoring and Diagnostics:\u003c\/strong\u003e Equipped with real-time feedback channels that allow maintenance teams to monitor motor thermal states, tracking errors, and bus voltage fluctuations, facilitating proactive maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eEVS9330-EP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eLenze\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eRange\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e9300-Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eType\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eServo Drives\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003ePower Rating\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e45.0 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e36.50 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e59.10 x 34.00 x 28.50 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eOrigin\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the EVS9330-EP be used for direct replacement of older 9300-Series units?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, it is a direct functional replacement within the 9300-Series architecture. It is essential to ensure that the firmware version and parameter configuration files are migrated correctly from the old unit to the replacement to ensure identical performance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat power supply requirements are critical for a 45.0 kW drive?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eGiven the high power draw, the drive requires a robust, low-impedance 3-phase supply. It is crucial to utilize the correct line chokes and RFI filters to maintain power quality and comply with EMC standards for electrical installations of this magnitude.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does this controller handle regenerative energy?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe EVS9330-EP can be configured for braking resistors to dissipate regenerative energy during deceleration phases. For systems with frequent high-inertia stops, consider external regenerative power supply modules to improve energy efficiency.\u003c\/p\u003e\n\u003ch3\u003eEngineering Integration and Operational Safety\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Mounting:\u003c\/strong\u003e Weighing 36.50 kg, the unit requires a reinforced backplate installation within the electrical cabinet. Ensure all mounting bolts are rated for industrial vibration, as the drive’s weight can cause mechanical stress over time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Management:\u003c\/strong\u003e Due to the high current levels involved in 45.0 kW operation, use appropriately sized copper busbars or heavy-gauge conductors. Separate all feedback cables (encoder lines) from power cables by a minimum distance of 300 mm to prevent signal noise from causing \"Positioning Error\" faults.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Management:\u003c\/strong\u003e The 45.0 kW power stage generates significant thermal load. The cabinet must be equipped with active forced-air ventilation (fans with adequate CFM ratings). Maintain a vertical air gap of at least 150 mm around the top and bottom of the drive.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Interlocks:\u003c\/strong\u003e The EVS9330-EP should be integrated into a SIL-rated safety circuit. Always include a primary line contactor that is de-energized during an Emergency Stop event, ensuring that the drive is electrically isolated from the main bus even if the internal power stage fails.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105055367531,"sku":"EVS9330-EP","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/evs9330-ep-1i2ryibdon3.png?v=1776236750","url":"https:\/\/www.plcprotech.com\/fr\/products\/lenze-evs9330-ep-9300-series-servo-position-controller","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}