{"product_id":"mbs-3000-060g1106-danfoss-compact-pressure-transmitter","title":"MBS 3000 (060G1106) Transmetteur de pression compact Danfoss","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMBS 3000 (060G1106)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a compact, heavy-duty pressure transmitter designed for use in almost all industrial applications, even under severe environmental conditions. As a cornerstone of the Danfoss industrial sensor portfolio, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDanfoss 060G1106 (060G1106)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides a reliable 4–20 mA output signal proportional to the measured pressure. This model is specifically calibrated for a 0–60 bar gauge pressure range, making it an ideal choice for B2B applications in hydraulic systems, air compressors, and water treatment plants where precision, vibration stability, and electromagnetic compatibility (EMC) are essential requirements.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe MBS 3000-2811-1AB04 is engineered for long-term stability. It features a piezo-resistive silicon sensing element housed in a high-grade acid-resistant stainless steel enclosure (AISI 316L). The electrical interface is a standardized Plug Pg 9 (EN175301-803-A), ensuring easy installation and maintenance. The pressure connection is a G ¼ A thread according to EN 837 standards. To handle the rigors of industrial environments, the transmitter is highly resistant to cavitation, liquid hammer, and pressure peaks, ensuring a long service life even in systems with fluctuating hydraulic loads.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMBS 3000 (060G1106)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMeasuring Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 - 60 bar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePressure Reference\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGauge (Relative)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Signal\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 - 20 mA (2-wire)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9 - 32 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eElectrical Connection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePlug Pg 9 (EN 175301-803-A)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePressure Connection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eG ¼ A (EN 837)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy (Typ.)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e± 0.5% FS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 °C to 85 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStainless Steel (AISI 316L)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does \"Gauge (Relative)\" pressure reference mean for the 060G1106?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eGauge pressure means the transmitter measures the pressure relative to the current atmospheric pressure. The sensor will output 4 mA when the system is open to the atmosphere and 20 mA when the system pressure reaches 60 bar above atmospheric levels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this transmitter handle high-vibration environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the MBS 3000 series is specifically designed for industrial machinery. It is tested for vibration stability according to IEC 60068-2-6 and shock resistance according to IEC 60068-2-27, making it suitable for mounting directly on pumps and engines.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the output signal protected against wiring errors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe transmitter includes polarity protection, meaning it will not be damaged if the positive and negative wires of the 4–20 mA loop are accidentally reversed during installation.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring for 4-20 mA Loop:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe MBS 3000 uses a 2-wire configuration. Connect the positive supply to Pin 1 and the return signal to Pin 2 of the Pg 9 plug. Ensure the total loop resistance does not exceed the limit determined by your supply voltage (\u003cspan class=\"math-inline\"\u003e$R_{loop} \\leq (V_{supply} - 9V) \/ 0.02A$\u003c\/span\u003e).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePressure Port Sealing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen installing the G ¼ A connection, use a suitable bonded seal (Dowty washer) or copper gasket to ensure a leak-proof interface. Avoid using PTFE tape on parallel threads as it can lead to improper seating or debris entering the sensing orifice.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo maintain the IP65 rating of the electrical connection, ensure the Pg 9 plug's gasket is correctly seated and the central screw is tightened. For outdoor installations, it is a best practice to point the cable entry downwards to prevent water from pooling at the connector interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102377566571,"sku":"060G1106","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/060g1106-hizko0a4nz3.png?v=1776136907","url":"https:\/\/www.plcprotech.com\/fr\/products\/mbs-3000-060g1106-danfoss-compact-pressure-transmitter","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}