{"product_id":"mitsubishi-electric-aj65bt-64rd4-cc-link-temperature-input-module","title":"CC-Link détecteur de température à résistance platine Pt 100 unité d'entrée température AJ65BT-64RD4","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDesigned for high-accuracy thermal monitoring in industrial network environments, the \u003cstrong\u003eMitsubishi Electric AJ65BT-64RD4\u003c\/strong\u003e serves as a specialized 4-channel platinum resistance temperature detector (RTD) input module within the CC-Link remote I\/O architecture. This module interfaces with 4-wire Pt100 and JPt100 RTD sensors, converting micro-resistance changes into highly precise digital outputs for PLC integration.\u003c\/p\u003e\n\n\u003cp\u003eThe unit features customizable resolution configurations, outputting either 16-bit signed binary values for standard setups or 32-bit signed binary values for applications requiring precise measurements up to three decimal places. Equipped with photocoupler isolation between the temperature inputs and the main CC-Link transmission lines, the module protects sensitive control circuitry from field-side electrical surges and noise interference.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSupports up to 4 independent temperature measurement channels using high-stability 4-wire RTD configurations.\u003c\/li\u003e\n  \u003cli\u003eCompatible with both Pt100 and JPt100 platinum resistance temperature detectors.\u003c\/li\u003e\n  \u003cli\u003eFlexible digital output options: 16-bit signed binary (-1800 to 6000) or 32-bit signed binary (-180000 to 600000).\u003c\/li\u003e\n  \u003cli\u003eOutstanding measurement resolution of 0.025 degC for high-precision thermal tracking.\u003c\/li\u003e\n  \u003cli\u003eFast conversion speed of 40 ms per channel, ensuring near real-time thermal response.\u003c\/li\u003e\n  \u003cli\u003eSecure photocoupler isolation between the measurement terminals and the CC-Link communication bus.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePrecision temperature monitoring in chemical processing and petrochemical plants.\u003c\/li\u003e\n  \u003cli\u003eEnvironmental chamber and industrial HVAC control.\u003c\/li\u003e\n  \u003cli\u003eBoiler and furnace thermal loop feedback systems.\u003c\/li\u003e\n  \u003cli\u003eProcess control monitoring in food, beverage, and pharmaceutical manufacturing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eCategory\u003c\/strong\u003e\n      \u003cstrong\u003eSpecification Parameter\u003c\/strong\u003e\n      \u003cstrong\u003eValue \/ Details\u003c\/strong\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd rowspan=\"3\"\u003eProduct Details\u003c\/td\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eMitsubishi Electric\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePart Number \/ Model\u003c\/td\u003e\n      \u003ctd\u003eAJ65BT-64RD4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNetwork \/ Communication Series\u003c\/td\u003e\n      \u003ctd\u003eCC-Link (Remote Device Station, Ver. 1)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd rowspan=\"5\"\u003eInput Specifications\u003c\/td\u003e\n      \u003ctd\u003eNumber of Channels\u003c\/td\u003e\n      \u003ctd\u003e4 channels\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSensor Compatibility\u003c\/td\u003e\n      \u003ctd\u003ePt100, JPt100 (4-wire type)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMeasurement Range\u003c\/td\u003e\n      \u003ctd\u003e-180 to 600 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSensor Detection Output Current\u003c\/td\u003e\n      \u003ctd\u003e1 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eResolution\u003c\/td\u003e\n      \u003ctd\u003e0.025 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd rowspan=\"3\"\u003ePerformance \u0026amp; Accuracy\u003c\/td\u003e\n      \u003ctd\u003eConversion Speed\u003c\/td\u003e\n      \u003ctd\u003e40 ms \/ channel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAccuracy (Ambient: 25 ± 5 degC)\u003c\/td\u003e\n      \u003ctd\u003e±0.1% (with respect to maximum value)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAccuracy (Ambient: \u0026lt;20 degC, \u0026gt;30 degC)\u003c\/td\u003e\n      \u003ctd\u003e±0.25% (with respect to maximum value)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd rowspan=\"4\"\u003eElectrical \u0026amp; Isolation\u003c\/td\u003e\n      \u003ctd\u003ePower Supply Voltage\u003c\/td\u003e\n      \u003ctd\u003e24 VDC (18 to 30 VDC allowable)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n      \u003ctd\u003e0.17 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eIsolation Method\u003c\/td\u003e\n      \u003ctd\u003ePhotocoupler isolation (Between input channels and CC-Link; channels are non-isolated from each other)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWithstand Voltage\u003c\/td\u003e\n      \u003ctd\u003e500 VAC for 1 minute\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd rowspan=\"4\"\u003ePhysical Characteristics\u003c\/td\u003e\n      \u003ctd\u003eHeight\u003c\/td\u003e\n      \u003ctd\u003e65 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWidth\u003c\/td\u003e\n      \u003ctd\u003e151.9 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDepth\u003c\/td\u003e\n      \u003ctd\u003e63 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWeight\u003c\/td\u003e\n      \u003ctd\u003e0.38 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd rowspan=\"3\"\u003eEnvironmental Limits\u003c\/td\u003e\n      \u003ctd\u003eOperating Ambient Temperature\u003c\/td\u003e\n      \u003ctd\u003e0 to 55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Ambient Temperature\u003c\/td\u003e\n      \u003ctd\u003e-20 to 75 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAmbient Operating Humidity\u003c\/td\u003e\n      \u003ctd\u003e10 to 90% RH (non-condensing)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eTerminal Connection Block\u003c\/th\u003e\n      \u003cth\u003eSpecification \/ Type\u003c\/th\u003e\n      \u003cth\u003eApplication\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCommunication \u0026amp; Power Terminal\u003c\/td\u003e\n      \u003ctd\u003e7-point, 2-piece terminal block (M3.5 screws)\u003c\/td\u003e\n      \u003ctd\u003eCC-Link network cable and 24 VDC unit power supply input\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eI\/O Channel Terminal\u003c\/td\u003e\n      \u003ctd\u003e27-point, 2-piece terminal block (M3.5 screws)\u003c\/td\u003e\n      \u003ctd\u003eRTD sensor connection (4-wire layout per channel)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Install within a secure, dust-free control cabinet. Mount securely using integrated DIN rail connectors or direct screw mounting.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use CC-Link dedicated high-shield cables for network communication. Ensure the 4-wire RTD signal lines are routed away from high-voltage AC cables to prevent electromagnetic coupling.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the ground terminal securely to the panel earth ground using a dedicated wire of 2 mm² or larger to assure optimal noise immunity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMeets IEC 61131-2 specifications for programmable controllers.\u003c\/li\u003e\n  \u003cli\u003eConforms to JIS B 3502 vibration and impact resistance standards.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":53102148157803,"sku":"AJ65BT-64RD4","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/AJ65BT-64RD4-ydr4drfvxsh.png?v=1776137227","url":"https:\/\/www.plcprotech.com\/fr\/products\/mitsubishi-electric-aj65bt-64rd4-cc-link-temperature-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}