{"product_id":"mitsubishi-electric-fr-a840-02160-2-60-fr-a800-inverter","title":"Variateur Mitsubishi Electric FR-A840-02160-2-60 FR-A800","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  Engineered for demanding industrial process control, the \u003cstrong\u003eMitsubishi Electric FR-A840-02160-2-60\u003c\/strong\u003e is a highly versatile three-phase 400V class variable frequency drive from the \u003cstrong\u003eFR-A800\u003c\/strong\u003e series. Designed with a conformally coated circuit board (3C2) and optimized for high-power induction and permanent magnet motors, this standard-model inverter offers exceptional speed and torque regulation across various industrial environments.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eKey Technical Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual-Rating Capability:\u003c\/strong\u003e Supports multiple rating profiles including Super Light Duty (SLD), Light Duty (LD), Normal Duty (ND), and Heavy Duty (HD) for optimal motor matching.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConformal PCB Coating:\u003c\/strong\u003e Features circuit board protection compliant with IEC 60721-3-3 Class 3C2, offering high resistance to corrosive gases and dust.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAdvanced Motor Control:\u003c\/strong\u003e Supports Real Sensorless Vector (RSV) control, closed-loop vector control, and PM sensorless vector control.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBuilt-In Safety Functionality:\u003c\/strong\u003e Integrated dual-channel emergency stop (Safe Torque Off - STO) compliant with EN ISO 13849-1 Category 3\/PLd.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eHeavy-duty industrial fans, pumps, and blowers\u003c\/li\u003e\n  \u003cli\u003eMaterial handling, conveyors, and automated gantry systems\u003c\/li\u003e\n  \u003cli\u003eExtruders, mixers, and industrial centrifuges\u003c\/li\u003e\n  \u003cli\u003eDeep-well water pumping systems and compressors\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; width: 35%;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eMitsubishi Electric\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eFR-A840-02160-2-60\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eSeries\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eFR-A800 Inverter Series\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eVoltage Class\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eThree-Phase 380 to 500 V AC, 50\/60 Hz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eSLD Rated Current (Super Light Duty)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e260 A\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eLD Rated Current (Light Duty)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e216 A\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eND Rated Current (Normal Duty)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e180 A\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eHD Rated Current (Heavy Duty)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e144 A\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eControl Logic\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eSource\/Sink logic selectable (CA Type)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eConformal PCB Coating\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eClass 3C2 (IEC 60721-3-3 compliant)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003ePlated Conductor\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eWithout\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOperating Ambient Temp\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-10 degC to 50 degC (non-freezing)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eCooling Method\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eForced Air Cooling\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eJapan\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e55.0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0; text-align: left;\"\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold; width: 35%;\"\u003eTerminal Designation\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold;\"\u003eFunction \/ Circuit Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eR\/L1, S\/L2, T\/L3\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eThree-phase AC power supply input (380-500V)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eU, V, W\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eThree-phase variable frequency output to motor\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eP\/+, N\/-\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eDC bus connection terminals (external brake unit option)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eSTF \/ STR\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eForward rotation start \/ Reverse rotation start control lines\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eS1, S2, SC\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eSafety stop input circuit terminals (STO compliant)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  The FR-A840-02160-2-60 can directly replace legacy FR-A740-02160-EC installations. Although physical footprint differences are minimal, the A800 control parameters must be remapped using FR Configurator2 to accommodate advanced vector motor algorithms and different terminal configurations.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  When operating in Super Light Duty (SLD) mode at 260A, overload capacity is capped at 110% for 60 seconds. High-inertia or high-torque start applications (such as crushers or heavy screw conveyors) must be run under Heavy Duty (HD) parameters to prevent instant overcurrent trips (E.OC1, E.OC2, E.OC3) during ramp-up cycles.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  Ensure the integrated EMC filter is enabled by confirming the grounding connector switch is in the correct position for your local grounding grid configuration. For long motor cables exceeding 100 meters, a dV\/dt or sine-wave filter must be installed to prevent voltage reflection damage to the motor windings.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 15px; margin-bottom: 1.5rem;\"\u003e\n  \u003cp style=\"margin: 0; font-weight: bold; color: #9b2c2c;\"\u003eCRITICAL WARNING: HIGH VOLTAGE RISK\u003c\/p\u003e\n  \u003cp style=\"margin: 5px 0 0 0; color: #9b2c2c; font-size: 0.95rem;\"\u003e\n    Isolate all input power supplies before handling control or main circuit terminations. Wait at least 10 minutes post-power-off to allow internal DC link capacitors to discharge below 50V DC. Verify voltage across P\/+ and N\/- terminals using a certified high-voltage multimeter before proceeding with wiring.\n  \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; margin-top: 2px;\"\u003e1\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eMount the inverter vertically inside a clean, IP54 or NEMA 12 enclosure if operating in environments prone to conductive dust or high ambient humidity.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; margin-top: 2px;\"\u003e2\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eConnect the primary ground terminal to the system ground busbar using the specified gauge to minimize ground loop currents and high-frequency noise EMI.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; margin-top: 2px;\"\u003e3\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eRoute control and communication wiring completely segregated from the heavy 3-phase AC input and motor output cabling to eliminate crosstalk.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":53102125089131,"sku":"FR-A840-02160-2-60","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/fr-a840-02160-2-60-zyf4ft0izcj.png?v=1776137456","url":"https:\/\/www.plcprotech.com\/fr\/products\/mitsubishi-electric-fr-a840-02160-2-60-fr-a800-inverter","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}