{"product_id":"mitsubishi-electric-fx5-enet-ip-melsec-iq-f-series-network-module","title":"Module réseau Mitsubishi Electric FX5-ENET\/IP série MELSEC iQ-F  ","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nEngineered to expand the connectivity of the MELSEC iQ-F controller platform, the \u003cstrong\u003eMitsubishi Electric FX5-ENET\/IP\u003c\/strong\u003e network module provides dedicated EtherNet\/IP and standard Ethernet communication capabilities. Integrating this module into your automation architecture enables the FX5 CPU to act as both an EtherNet\/IP scanner (master) and adapter (slave) simultaneously, facilitating seamless data exchange with remote I\/O, variable frequency drives, and third-party instruments. Operating on a \u003cstrong\u003e24 V DC\u003c\/strong\u003e internal power supply with a low current draw of \u003cstrong\u003e110 mA\u003c\/strong\u003e, it delivers high-performance industrial networking without putting unnecessary strain on the system's power budget.\n\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eDual-role capability functioning as both an EtherNet\/IP CIP communication scanner and adapter.\u003c\/li\u003e\n  \u003cli\u003eSupports standard Ethernet communication protocols alongside industrial EtherNet\/IP on a single physical link.\u003c\/li\u003e\n  \u003cli\u003eSeamless integration with GX Works3 configuration software for drag-and-drop network mapping.\u003c\/li\u003e\n  \u003cli\u003eCompact form factor designed for direct right-side extension bus connection to FX5U or FX5UC CPU modules.\u003c\/li\u003e\n  \u003cli\u003eDiagnostic LED array for real-time link status, module health, and network collision monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMulti-Vendor Integration:\u003c\/strong\u003e Connecting MELSEC iQ-F controllers to third-party EtherNet\/IP compliant devices such as sensors and vision systems.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDistributed Field I\/O:\u003c\/strong\u003e Managing remote I\/O drops across large manufacturing footprints with minimal latency.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDrive Control:\u003c\/strong\u003e Real-time speed and torque command routing to compatible variable speed drives over industrial Ethernet.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSCADA and HMI Bridging:\u003c\/strong\u003e Serving high-throughput data to supervisor level control rooms and operator interfaces.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 0.75rem; font-weight: bold;\"\u003eSpecification\u003c\/th\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eMitsubishi Electric\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eFX5-ENET\/IP\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eSeries\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eMELSEC iQ-F Series\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eModule Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eEtherNet\/IP Network Module\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eInternal Power Supply\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e24 V DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eCurrent Consumption\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e110 mA\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eTransmission Rate\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e100 Mbps \/ 10 Mbps (Auto-negotiation)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eCommunication Interface\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eRJ45 Port (1 port)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eMax. Cable Segment Length\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e100 meters\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1.5 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eStatus LED Configurations\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eLED Indicator\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 0.75rem; font-weight: bold;\"\u003eOperational State Meaning\u003c\/th\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eRUN\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eON: Normal operation; OFF: Power off or hardware watchdog error.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eERR\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eFlashing\/ON: Hardware error or incorrect module parameter configuration.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eNS (Network Status)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eGreen (ON): Online connected; Red (Flashing): IP address conflict or connection timeout.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eMS (Module Status)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eGreen (ON): Module is operating normally; Red (ON): Unrecoverable hardware failure.\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nUnlike the built-in Ethernet port on FX5U CPU modules, which primarily processes CC-Link IE Field Basic, Modbus\/TCP, and MELSOFT connection protocols, the FX5-ENET\/IP is explicitly optimized for heavy-duty CIP (Common Industrial Protocol) traffic. If your network topology mandates cyclic, high-speed Class 1 implicit messaging with third-party components, this module must be appended. Note that firmware version 1.040 or higher in the host FX5 CPU is required for full feature exploitation.\n\u003c\/p\u003e\n\n\u003ch4\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nDuring high-traffic cyclic communication periods, network jitter can trigger NS fault codes. It is highly recommended to isolate EtherNet\/IP messaging traffic from plant-wide IT office networks using managed switches with IGMP snooping configured. When mounting multiple extension modules, position the FX5-ENET\/IP as close to the CPU as possible to ensure structural bus signaling integrity.\n\u003c\/p\u003e\n\n\u003ch4\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nAlways use Category 5e (or better) Double-Shielded Twisted Pair (S\/FTP) cabling in high electromagnetic noise environments. Avoid routing the network cable parallel to high-voltage lines or variable frequency drive output cables to prevent induced noise from corrupting data packets.\n\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0.5rem 0 0 0;\"\u003e\n    Ensure all AC and DC external power sources feeding the host PLC and associated field circuitry are completely de-energized before mounting, removing, or wiring the FX5-ENET\/IP network module. Failure to do so can result in electrical shock, hardware failure, or unstable CPU bus behavior.\n  \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; color: #2d3748;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 1.75rem; height: 1.75rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e1\u003c\/div\u003e\n    \u003cdiv\u003eAlign the module expansion connector with the right-side extension port of the host FX5 CPU or preceding expansion module.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 1.75rem; height: 1.75rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e2\u003c\/div\u003e\n    \u003cdiv\u003eCarefully press the module onto the DIN rail until the mounting hook clicks firmly into position. Secure the module extension joint latch.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 1.75rem; height: 1.75rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e3\u003c\/div\u003e\n    \u003cdiv\u003eConnect the system ground terminal to an isolated, low-impedance functional earth ground point. Do not share this ground path with high-current equipment.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 1.75rem; height: 1.75rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e4\u003c\/div\u003e\n    \u003cdiv\u003eInsert the shielded Ethernet RJ45 network plug into the communication port until it snaps securely. Power up the system and proceed with the hardware parameter mapping via GX Works3.\u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":53102123090283,"sku":"FX5-ENET\/IP","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/fx5-enetip-omqappxptnu.png?v=1776137559","url":"https:\/\/www.plcprotech.com\/fr\/products\/mitsubishi-electric-fx5-enet-ip-melsec-iq-f-series-network-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}