{"product_id":"mitsubishi-electric-fx5u-80mt-ess-melsec-iq-f-series-plc-cpu-module","title":"FX5U-80MT\/ESS | Mitsubishi Electric | Modules CPU FX5U","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDesigned as a high-performance control engine for the MELSEC iQ-F platform, the \u003cstrong\u003eMitsubishi Electric FX5U-80MT\/ESS\u003c\/strong\u003e programmable logic controller offers exceptional processing speeds and integrated industrial functionalities. This module features \u003cstrong\u003e80 built-in I\/O channels\u003c\/strong\u003e (comprising 40 source\/sink 24V DC inputs and 40 source-type transistor outputs) designed to coordinate complex automation tasks. The controller incorporates native analog inputs and outputs, a dedicated RS-485 port, and an Ethernet interface to support diverse industrial communication requirements directly from the base unit without requiring additional expansion cards.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Speed System Bus:\u003c\/strong\u003e Facilitates ultra-fast communication with extension modules, minimizing signal propagation delay.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated Analog I\/O:\u003c\/strong\u003e Built-in 2-channel analog input (0 to 10 V DC) and 1-channel analog output (0 to 10 V DC) for direct sensor and actuator interfacing.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAdvanced Positioning:\u003c\/strong\u003e Supports built-in 4-axis positioning control with dedicated high-speed counter inputs.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial Communications:\u003c\/strong\u003e Native RJ45 Ethernet port and screw-terminal RS-485 connection for seamless integration into factory networks.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSD Card Slot:\u003c\/strong\u003e Onboard memory card slot for program logging, firmware updates, and recipe management.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eHigh-speed packaging and sorting machinery.\u003c\/li\u003e\n  \u003cli\u003eMulti-axis pick-and-place gantry systems.\u003c\/li\u003e\n  \u003cli\u003eWater treatment control panels with analog flow\/pressure monitoring.\u003c\/li\u003e\n  \u003cli\u003eConveyor control and material handling distribution systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; font-family: sans-serif; font-size: 0.9rem;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0; text-align: left;\"\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eMitsubishi Electric\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eModel Family\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eMELSEC iQ-F Series (FX5U)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eSupply Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e100 to 240 V AC (+10% \/ -15%), 50\/60 Hz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003ePower Consumption\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e45 W\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eTotal Built-in I\/O Points\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e80 points (40 inputs, 40 outputs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eInput Specifications\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e24 V DC, 5.3 mA (X0 to X17) \/ 4.0 mA (X20 and later), Sink or Source configurable\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOutput Specifications\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eTransistor (Source type), 5 to 30 V DC, 0.5 A per point\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eBuilt-in Analog Inputs\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e2 channels (0 to 10 V DC, input resistance 115 kOhms, 12-bit resolution)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eBuilt-in Analog Output\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1 channel (0 to 10 V DC, load resistance 2 kOhms to 1 MOhms, 12-bit resolution)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eBuilt-in Communication Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1x RJ45 Ethernet (100Base-TX\/10Base-T), 1x RS-485 (terminal block)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0 to 55 degC (32 to 131 degF)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eJapan\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1.2 kg (Net), 1.45 kg (Packaged)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e305 mm x 110 mm x 100 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; font-family: sans-serif; font-size: 0.9rem;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0; text-align: left;\"\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold;\"\u003eTerminal Block Section\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold;\"\u003eSignal \/ Pin Assignment\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold;\"\u003eWiring Description\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003ePower Terminals\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eL, N, PE\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e100 to 240 V AC supply line, neutral, and physical protective earth.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eInput Terminals\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eS\/S, X0 to X47\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eConfigure S\/S terminal for sink (connected to 24V) or source (connected to 0V) operations.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOutput Terminals\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e+V0 to +V4, Y0 to Y47\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eSource transistor outputs. External load connected between Y terminal and 0V line.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eAnalog Terminals\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eV+, V-, CH1, CH2\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eVoltage inputs\/outputs (0 to 10 V DC) for native processing. Shielded cables required.\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThis controller serves as the direct evolutionary upgrade path for legacy FX3U systems. Migration from FX3U to FX5U requires software conversion via GX Works3. Be aware that the I\/O terminal block alignment and physical footprint differ from older designs; ensure layout diagrams are updated to accommodate the compact housing of the FX5U model.\u003c\/p\u003e\n\n\u003ch4\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhen utilizing all 40 transistor outputs under continuous maximum switching states in a fully populated cabinet, local thermal limits can be reached. Ensure the enclosure provides adequate passive ventilation or active cooling to maintain ambient temperatures below 55 degC. To prevent inductive kickback from damage, external freewheeling diodes must be mounted parallel to inductive DC loads (solenoids, contactor coils) connected to Y0-Y47.\u003c\/p\u003e\n\n\u003ch4\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eTo configure the sink\/source digital inputs, the S\/S terminal must be explicitly jumpered. Wiring S\/S to 24V establishes a sink input loop, whereas wiring S\/S to 0V establishes a source loop. Do not leave the S\/S terminal floating. For RS-485 communications, enable the terminal resistor (110 Ohm or 330 Ohm) via the built-in switch at physical bus boundaries to prevent data reflection and signal degradation.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e Disconnect all primary power before mounting, terminating, or modifying wiring on the PLC. Failure to isolate power can result in permanent equipment damage, arc flash, or personal injury. Ensure the auxiliary 24 V DC power supply is monitored and protected by an external fast-acting fuse.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; min-width: 28px; height: 28px; border-radius: 50%; background-color: #2b6cb0; color: #ffffff; font-weight: bold; margin-right: 12px; margin-top: 2px;\"\u003e1\u003c\/span\u003e\n    \u003cp style=\"margin: 0; color: #2d3748;\"\u003eMount the PLC onto a standard 35mm DIN rail inside a protective, IP54-rated or better cabinet to avoid contamination from conductive dust or moisture.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; min-width: 28px; height: 28px; border-radius: 50%; background-color: #2b6cb0; color: #ffffff; font-weight: bold; margin-right: 12px; margin-top: 2px;\"\u003e2\u003c\/span\u003e\n    \u003cp style=\"margin: 0; color: #2d3748;\"\u003eEnsure the physical ground terminal (PE) is connected directly to the main cabinet ground bus using a short, low-impedance conductor (minimum 2 mm² copper wire).\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; min-width: 28px; height: 28px; border-radius: 50%; background-color: #2b6cb0; color: #ffffff; font-weight: bold; margin-right: 12px; margin-top: 2px;\"\u003e3\u003c\/span\u003e\n    \u003cp style=\"margin: 0; color: #2d3748;\"\u003eIsolate high-voltage AC lines from low-voltage DC and communication pathways in separate wire ducts to avoid EMI coupling.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":53102128300395,"sku":"FX5U-80MT\/ESS","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/FX5U-80MTESS-on5wzgwyrju.png?v=1776137568","url":"https:\/\/www.plcprotech.com\/fr\/products\/mitsubishi-electric-fx5u-80mt-ess-melsec-iq-f-series-plc-cpu-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}