{"product_id":"mitsubishi-electric-gt1575-stbd-got1000-series-hmi-graphic-operation-terminal","title":"GT1575-STBD | Mitsubishi Electric | Pilote isolant","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  Optimizing operator control and plant-floor visualization, the \u003cstrong\u003eMitsubishi Electric GT1575-STBD\u003c\/strong\u003e serves as a high-performance human-machine interface (HMI) within the legacy GOT1000 platform. This robust terminal bridges the gap between complex automation systems and real-time operator monitoring, delivering crisp graphical rendering and reliable communication interfaces.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eKey Technical Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Resolution Display:\u003c\/strong\u003e Equipped with a 10.4-inch TFT color LCD screen offering a clear 640 x 480 pixel VGA resolution.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMulti-Protocol Connectivity:\u003c\/strong\u003e Built-in physical ports supporting RS-232, RS-422, and RS-485 serial communication protocols for seamless PLC integration.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial-Grade Protection:\u003c\/strong\u003e Features an IP67F front-panel rating, providing robust resistance against dust, water, and oil mist in demanding environments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOnboard Memory:\u003c\/strong\u003e Contains 9 MB of internal flash memory dedicated to project screens, system OS, and data logging configurations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eAutomotive assembly lines and robotic work cell monitoring.\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater treatment facility control consoles.\u003c\/li\u003e\n  \u003cli\u003ePackaging machinery and high-speed food processing lines.\u003c\/li\u003e\n  \u003cli\u003eDiscrete manufacturing and CNC machine tool operator panels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; width: 30%;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eMitsubishi Electric\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eModel \/ SKU\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eGT1575-STBD\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eSeries\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eGOT1000 (GT15)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eDisplay Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eTFT Color LCD\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eDisplay Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e10.4 Inches\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eResolution\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e640 x 480 Pixels (VGA)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eOnboard Memory\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e9 MB Flash\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCommunication Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eRS-232, RS-422, RS-485\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eFront Panel Protection\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eIP67F\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e0 to 50 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0; text-align: left; font-weight: bold;\"\u003e\n        \u003cth style=\"padding: 0.75rem; width: 30%;\"\u003eInterface Port\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem;\"\u003eFunctional Assignment \/ Connection Target\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eRS-232\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003ePC connection for project upload\/download, barcode readers, or serial PLC links.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eRS-422\/485\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eDirect multi-drop connection to Mitsubishi MELSEC PLCs or third-party controllers.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eExtension Interface\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eAccepts optional communication units (Ethernet, CC-Link, MELSECNET\/H modules).\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  The GT1575-STBD is a core component of the legacy GOT1000 series. When migrating to the newer GOT2000 series (such as the GT2510-WXTBD), screen projects created in GT Designer3 can be automatically converted, though physical panel cutout dimensions and communication cable pinouts must be verified for mechanical compatibility.\n\u003c\/p\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  Ensure the HMI is mounted vertically to maintain optimal heat dissipation. In high-temperature environments exceeding 40 degC, avoid placing heat-generating devices directly below the terminal. Ensure the rear cooling vents remain completely unobstructed.\n\u003c\/p\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  Always use high-quality shielded twisted-pair cables for the RS-422\/485 communication lines. Ground the shield wire at a single point (preferably at the PLC side) to prevent ground loops and shield the serial data from high-frequency electromagnetic noise generated by nearby variable frequency drives (VFDs).\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; border-radius: 4px;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003e\n    Isolate all external power sources before attempting mechanical installation, wiring, or module replacement. Failure to completely de-energize the system can result in severe electrical shock, hardware damage, or erratic control system behavior.\n  \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0; padding-top: 2px;\"\u003ePrepare the panel cutout according to the exact mechanical dimensions specified in the GOT1000 hardware manual.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0; padding-top: 2px;\"\u003eEnsure the waterproof packing gasket is properly seated in the HMI groove before inserting the unit into the panel cutout.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0; padding-top: 2px;\"\u003eSecure the terminal using the supplied mounting fixtures, tightening the screws to the specified torque to maintain the IP67F front seal without warping the bezel.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0; padding-top: 2px;\"\u003eConnect the functional ground terminal to a dedicated class-D ground (100 ohms or less) using a minimum of 2 mm² wire to ensure proper noise immunity.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":53102124532075,"sku":"GT1575-STBD","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/gt1575-stbd-vgk0325tq4t.png?v=1776137592","url":"https:\/\/www.plcprotech.com\/fr\/products\/mitsubishi-electric-gt1575-stbd-got1000-series-hmi-graphic-operation-terminal","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}