{"product_id":"mitsubishi-electric-gt1675m-vtbd-got1000-hmi-operator-terminal","title":"GT1675M-VTBD | Mitsubishi Electric | GT16 GOT1000 IHM","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eFor complex industrial visualization and control interface requirements, the \u003cstrong\u003eMitsubishi Electric GT1675M-VTBD\u003c\/strong\u003e operator terminal delivers high-performance monitoring within the \u003cstrong\u003eGOT1000\u003c\/strong\u003e platform. Engineered to operate under demanding environmental conditions, this hardware integration unit features a \u003cstrong\u003eDC24V\u003c\/strong\u003e operating input and robust electrical protection. Key parameters such as a maximum power consumption of \u003cstrong\u003e38W or less\u003c\/strong\u003e and an inrush current envelope of \u003cstrong\u003e12A or less\u003c\/strong\u003e make it a highly stable interface for critical PLC architectures.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eHigh-fidelity TFT color display offering clear machine visualization and diagnostics.\u003c\/li\u003e\n  \u003cli\u003eRobust power supply tolerance accommodating fluctuations from +25% down to -20%.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in transient protection designed to withstand short-duration voltage dips.\u003c\/li\u003e\n  \u003cli\u003eHigh-density noise immunity to resist electromagnetic interference in high-power cabinet layouts.\u003c\/li\u003e\n  \u003cli\u003eIntegrated communication ports for seamless PLC, drive, and peripheral coordination.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eAutomotive assembly line tracking and cell-level control interfaces.\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater plant monitoring stations.\u003c\/li\u003e\n  \u003cli\u003eMulti-axis packaging machinery and material handling automation systems.\u003c\/li\u003e\n  \u003cli\u003ePower distribution monitoring panels and heavy machinery control.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications Table\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"padding: 12px; text-align: left; font-weight: bold;\"\u003eTechnical Parameter\u003c\/th\u003e\n        \u003cth style=\"padding: 12px; text-align: left; font-weight: bold;\"\u003eValue \/ Specification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003eMitsubishi Electric\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003eGT1675M-VTBD\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eSeries\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003eGOT1000 (GT16)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eInput Power Supply Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003e24V DC (+25%, -20%)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003ePower Consumption\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003e38W or less\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eInrush Current\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003e12A or less (duration: 55ms, maximum load)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eAllowable Momentary Power Failure Time\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003e10 ms or less\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eNoise Immunity\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003e500Vp-p noise voltage (measured via noise simulator)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003e8.0 Kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003e310 mm x 240 mm x 90 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"padding: 12px; text-align: left; font-weight: bold;\"\u003eInterface Port\u003c\/th\u003e\n        \u003cth style=\"padding: 12px; text-align: left; font-weight: bold;\"\u003eFunctional Specifications\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eEthernet\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003e1-Port 10BASE-T\/100BASE-TX for PLC connection and data logging\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eUSB Host\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003eType-A High-Speed port for USB storage, data backup, and OS updates\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eUSB Device\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003eMini-B port for high-speed PC communication and programming transfers\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eRS-232\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003eD-Sub 9-pin interface for serial PLC control and barcode reader attachment\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eRS-422\/485\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003eMulti-drop serial channel for multi-station automation networks\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe GT1675M-VTBD functions as a direct drop-in modernization path for older legacy GT1575 series units. When upgrading, display layout files can be quickly imported and converted using the GT Works3 configuration software suite. Ensure that the 24VDC system supply matches the power configuration of the incoming terminal, as some legacy GT15 variants operated on 100-240VAC.\u003c\/p\u003e\n\n\u003ch3\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eTo protect against local thermal issues, verify that ambient installation cabinet temperatures do not exceed 50 degC. Operating the terminal consistently above its rated temperature parameters will accelerate the degradation of the liquid crystal screen backlight. In highly inductive environments where heavy-duty contactors switch frequently, separate the HMI’s 24VDC feed from the inductive load power lines to prevent system resets.\u003c\/p\u003e\n\n\u003ch3\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003ePrioritize signal stability by connecting the Functional Ground (FG) terminal directly to a dedicated class-D ground (ground resistance 100 ohms or less) using a minimum 2 mm² copper grounding wire. Never run communication or Ethernet cabling parallel to the high-voltage mains or variable frequency drive (VFD) output lines. Maintaining safe physical clearance prevents signal-to-noise ratio degradation during runtime operations.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING: SAFETY FIRST\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eBefore initiating physical mounting or terminal block connection procedures, completely de-energize the enclosure's main power switch. Ensure all residual electrical energy has dissipated to prevent equipment damage or operator injury.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003col style=\"list-style-type: none; padding-left: 0; margin-bottom: 1.5rem;\"\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; margin-right: 12px; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    \u003cspan style=\"color: #2d3748;\"\u003ePosition the unit into the cutout, ensuring the waterproof packing gasket is seated flat without twists or bunching to maintain the IP rating.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; margin-right: 12px; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    \u003cspan style=\"color: #2d3748;\"\u003eTighten all supplied panel mounting brackets in a cross-pattern configuration to the specified torque range to avoid display bezel distortion.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; margin-right: 12px; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    \u003cspan style=\"color: #2d3748;\"\u003eInsert and secure the DC24V power supply line wires, paying careful attention to correct polarity alignment.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; margin-right: 12px; font-weight: bold; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n    \u003cspan style=\"color: #2d3748;\"\u003eRun the communication cables directly to their dedicated physical network nodes, keeping them clear of high-voltage wiring paths.\u003c\/span\u003e\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":53102127513963,"sku":"GT1675M-VTBD","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/gt1675m-vtbd-mshou412i5q.png?v=1776137600","url":"https:\/\/www.plcprotech.com\/fr\/products\/mitsubishi-electric-gt1675m-vtbd-got1000-hmi-operator-terminal","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}