{"product_id":"mitsubishi-electric-gt2710-stba-got2000-series-advanced-hmi-module","title":"GT2710-STBA | Mitsubishi Electric | Modèle avancé avec fonctions multi-touch gestuelles","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eEngineered to deliver high-resolution process visualization and intuitive system control, the Mitsubishi Electric GT2710-STBA serves as a high-performance operator interface within complex automation architectures. Featuring a 10.4-inch SVGA TFT color display, this Human-Machine Interface (HMI) integrates capacitive multi-touch gesture capability, allowing operators to execute pinch-to-zoom, swipe, and dual-hand control actions directly on the factory floor. Equipped with an industrial-grade AC power supply, it is designed for installation in electrical control cabinets operating under rugged environmental and electrical conditions.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMulti-Touch Capability:\u003c\/strong\u003e Supports standard gesture operations to prevent accidental inputs and streamline complex panel interactions.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTFT Color Screen:\u003c\/strong\u003e Displays process parameters with high-contrast SVGA resolution (800 x 600 pixels) for crisp text and detailed graphic screens.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWide Input Voltage Range:\u003c\/strong\u003e Operates reliably on alternating current from 100 to 240 VAC with tolerance configurations of +10% to -15%.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePhysical Resilience:\u003c\/strong\u003e Built with a black frame and certified to withstand mechanical impacts up to 147 m\/s2 (15G) across three orthogonal axes.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRobust Insulating Barrier:\u003c\/strong\u003e Withstands test voltages of up to 1500 VAC for 1 minute between the live power terminals and the chassis ground.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eAutomotive assembly plants and robotic manufacturing lines.\u003c\/li\u003e\n  \u003cli\u003ePumping, filtration, and dosing systems in water and wastewater facilities.\u003c\/li\u003e\n  \u003cli\u003ePackaging, sorting, and material handling systems requiring rapid manual overrides.\u003c\/li\u003e\n  \u003cli\u003eChemical processing and environmental monitoring control panels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold; color: #1a365d;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold; color: #1a365d;\"\u003eValue \/ Specification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eMitsubishi Electric\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eGT2710-STBA\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eSeries\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eGOT2000 Series (GT27)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eDisplay Size \u0026amp; Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e10.4-inch SVGA TFT Color Display\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eResolution\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e800 x 600 Pixels\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eInput Power Supply Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e100 to 240 VAC (+10%, -15%), 50\/60 Hz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eMaximum Power Load\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e41 W or less\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003ePower Consumption (Standalone)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e17 W (10 W with backlight disabled)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eInrush Current\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e60 A or less (duration 2 ms, 25 degC ambient)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOperating Temperature (Horizontal)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0 to 55 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOperating Temperature (Vertical)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0 to 50 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOperating Humidity\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e10% to 90% RH (non-condensing)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003ePermissible Instantaneous Failure Time\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eWithin 20 ms (at 100 VAC or above)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eInsulation Resistance\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e10 MOhm or higher (measured at 500 VDC)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003ePhysical Dimensions (W x H x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e303 mm x 218 mm x 25 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eWeight (Excluding Brackets)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e2.1 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e8.0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #1a365d; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe unit serves as a functional replacement path for older GT1675-VNBA and GT1675-VNBA series operator terminals. When migrating projects via GT Works3, confirm that system fonts, touch-key touch zones, and direct communication settings are compiled for the GOT2000 hardware layer to ensure screen scaling and touch responsiveness operate as designed.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #1a365d; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eNote the physical mounting orientation thermal penalty. A vertical configuration reduces convective heat dissipation capacity, reducing the allowable safe ambient envelope limit from 55 degC to 50 degC. Ensure sufficient enclosure volume is reserved to prevent hotspot build-up, especially when mounting direct-drive contactors or high-heat variable speed drives directly beneath the terminal cut-out.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #1a365d; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eUse separate physical runs for the AC feed and any signal cabling to prevent inductive coupling. The screw terminal blocks (M3 type) must be torqued to a range of 0.5 to 0.8 N.m using insulated tools. Always connect the functional ground terminal directly to a dedicated Class D low-impedance ground point (less than 100 Ohms) to minimize electromagnetic noise from local power electronics.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 15px; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 5px;\"\u003eCRITICAL SAFETY WARNING\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0; font-size: 0.95rem;\"\u003eEnsure all main, auxiliary, and control power feeds to the enclosure are completely de-energized, locked out, and tagged out prior to making physical contact with the terminals. Confirm the absence of hazardous residual voltage with a calibrated test instrument before initiating wiring steps.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 12px;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003ePrepare the panel door cutout according to the installation manual template dimensions. Ensure the structural plate is level, rigid, and clear of rough burrs or metal chips.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 12px;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eVerify that the waterproof gasket is correctly seated around the back panel's perimeter. Insert the screen from the front panel into the prepared cabinet cutout.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 12px;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eAttach the mounting brackets from the rear and tighten the mounting screws evenly to secure the gasket seal and prevent mechanical distortion of the HMI bezel.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 12px;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; font-weight: bold; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eStrip incoming 100-240 VAC wire conductors to size (0.75 to 2 mm2). Crimp clean insulated spade or ring terminals, connect them to the M3 screw blocks, and torque securely to standard specs.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":53102127841643,"sku":"GT2710-STBA","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/gt2710-stba-sejy3n1ly3o.png?v=1776137632","url":"https:\/\/www.plcprotech.com\/fr\/products\/mitsubishi-electric-gt2710-stba-got2000-series-advanced-hmi-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}