{"product_id":"mitsubishi-electric-l06cpu-cm-melsec-l-series-cpu-module","title":"L06CPU-CM | Mitsubishi Electric | Module CPU","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDesigned for high-speed, high-accuracy control in medium-to-large industrial automation systems, the Mitsubishi Electric \u003cstrong\u003eL06CPU-CM\u003c\/strong\u003e serves as a high-performance \u003cstrong\u003eCPU module\u003c\/strong\u003e within the modular MELSEC-L Series controller platform. This processing unit features a rack-free, expandable architecture that allows modules to connect directly via built-in interlocking joints, eliminating the need for a traditional backplane bus and saving significant panel space.\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eL06CPU-CM\u003c\/strong\u003e provides robust memory allocation, including dedicated program memory, standard RAM, and standard ROM, enabling it to handle complex sequencing, motion control, and data logging tasks. This unit is highly suited for decentralized control architectures and integrates seamlessly with various fieldbus networks and industrial communications protocols.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh-speed program execution and rapid instruction processing times.\u003c\/li\u003e\n  \u003cli\u003eRack-free design with integrated module connection mechanism.\u003c\/li\u003e\n  \u003cli\u003eSubstantial memory capacity supporting complex structured programming and user function blocks.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in diagnostic utilities and error-checking protocols.\u003c\/li\u003e\n  \u003cli\u003eCompact physical footprint optimized for space-constrained control cabinets.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eAutomated packaging and labeling machinery.\u003c\/li\u003e\n  \u003cli\u003eMaterial handling and conveyor sorting systems.\u003c\/li\u003e\n  \u003cli\u003eWater treatment and chemical dosing processes.\u003c\/li\u003e\n  \u003cli\u003eHVAC, environmental, and building automation control systems.\u003c\/li\u003e\n  \u003cli\u003eFood and beverage production lines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMitsubishi Electric\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eL06CPU-CM\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMELSEC-L Series\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCentral Processing Unit (CPU) Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProgram Memory Capacity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e240K bytes\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStandard RAM\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e768K bytes\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStandard ROM\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1024K bytes\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFile Register Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e384K\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProgram Memory Unit Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 step (4 bytes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStandard RAM Unit Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e128 steps (512 bytes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStandard ROM Unit Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e128 steps (512 bytes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFile Size Setting Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 to 512K points\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eApproximate Shipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3.0 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Mount secure on a standard 35mm DIN rail using the module's rear DIN rail hooks. Ensure the interlocking side joints are fully engaged with adjacent modules before powering up the system.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCooling and Ventilation:\u003c\/strong\u003e Maintain a minimum clearance of 30 mm above and below the CPU module to facilitate natural convection cooling. Do not block the ventilation slits on the top and bottom of the housing.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Route communication and signal cables away from high-voltage AC lines to minimize electromagnetic interference (EMI). Ensure the power supply module is rated appropriately for the total system load.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSystem Handling:\u003c\/strong\u003e Always switch off the main system power supply before attaching, detaching, or wiring any module in the configuration.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":53102145306987,"sku":"L06CPU-CM","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/l06cpu-cm-u4w3aj1w2au.png?v=1776137785","url":"https:\/\/www.plcprotech.com\/fr\/products\/mitsubishi-electric-l06cpu-cm-melsec-l-series-cpu-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}