{"product_id":"mitsubishi-electric-lj72gf15-t2-melsec-l-series-cc-link-ie-field-network-head-module","title":"Module principal réseau de terrain CC-Link IE de la série MELSEC L Mitsubishi Electric LJ72GF15-T2","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eFacilitating high-speed deterministic communication within distributed control architectures, the \u003cstrong\u003eMitsubishi Electric LJ72GF15-T2\u003c\/strong\u003e serves as a rugged interface node linking remote MELSEC L Series I\/O and intelligent function modules to a CC-Link IE Field Network. This head module translates high-speed network frames into local backplane transactions, allowing seamlessly distributed physical arrangements without sacrificing I\/O response speeds. Designed with dual RJ45 ports, it accommodates robust redundant and ring topologies to maximize system uptime in continuous-process industrial environments.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.25rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.25rem;\"\u003eGigabit Ethernet physical layer delivering deterministic 1 Gbps transmission speed.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.25rem;\"\u003eFlexible network topology support including line, star, mixed, and high-availability ring structures.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.25rem;\"\u003eAccommodates up to 10 local MELSEC L Series extension modules per head node.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.25rem;\"\u003eIntegrated RAS diagnostic tools including event logging, system test modes, and error tracking.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.25rem;\"\u003eDual communication ports allowing simple daisy-chaining without external switches.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.25rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.25rem;\"\u003eDistributed conveyor control systems and logistics hubs.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.25rem;\"\u003eMulti-station automotive assembly and welding cells.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.25rem;\"\u003eWater treatment plants with physically isolated pumping stations.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.25rem;\"\u003ePackaging and bottling machines requiring high-density remote I\/O layout.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #cbd5e0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 0.75rem; font-weight: bold; color: #1a365d;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 0.75rem; font-weight: bold; color: #1a365d;\"\u003eSpecification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eMitsubishi Electric\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eLJ72GF15-T2\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eNetwork Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eCC-Link IE Field Network\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eTransmission Rate\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1 Gbps\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCommunication Scheme\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eToken passing (Deterministic)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eMaximum Connected Modules\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e10 slots (local backplane extension)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eInterface Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e2 x RJ45 (PORT1 and PORT2)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCable Requirement\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eCategory 5e or higher (Double-shielded STP)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eInternal Current Consumption (5 VDC)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1.00 A\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eNet Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e0.23 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1.50 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #cbd5e0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 0.75rem; font-weight: bold; color: #1a365d;\"\u003eTerminal \/ Port\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 0.75rem; font-weight: bold; color: #1a365d;\"\u003eFunction \/ Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePORT 1\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eCC-Link IE Field upstream \/ downstream connection (RJ45)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePORT 2\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eCC-Link IE Field loop-back \/ downstream connection (RJ45)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eFG Terminal\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eFunctional ground connection for shield noise dissipation\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe LJ72GF15-T2 is specifically designed for the MELSEC L Series modular platform. Ensure your engineering environment is updated with GX Works2 to allow seamless network profile registration of this specific head module station.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThis module relies on passive ventilation. In high-density electrical cabinets with ambient temperatures trending toward the upper limit, ensure at least 80mm of vertical clearances above and below the module assembly to prevent localized overheating and subsequent fieldbus dropouts.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1.5rem;\"\u003eFor reliable 1 Gbps performance, standard unshielded patch cords are strictly prohibited. You must use double-shielded industrial-grade Category 5e (STP) cables. Ensure the metal shield of the RJ45 jack is properly grounded to the DIN rail ground assembly via the head module's functional ground connection.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; border-radius: 4px;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eIsolate and lock out all external power supplies connected to the master PLC and the remote node prior to physical hardware mounting, module joining, or communication cable termination. Failure to de-energize can damage sensitive internal backplane components.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; color: #2d3748; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 0.75rem;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; width: 1.5rem; height: 1.5rem; border-radius: 50%; display: inline-flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    \u003cspan\u003eMount the LJ72GF15-T2 module firmly onto a standardized 35mm symmetrical DIN rail.\u003c\/span\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 0.75rem;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; width: 1.5rem; height: 1.5rem; border-radius: 50%; display: inline-flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    \u003cspan\u003eSlide and lock local L Series I\/O or intelligent modules to the right of the head module, ensuring proper backplane connector engagement.\u003c\/span\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 0.75rem;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; width: 1.5rem; height: 1.5rem; border-radius: 50%; display: inline-flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    \u003cspan\u003eConnect double-shielded STP cables into PORT 1 and PORT 2 based on your physical topology design.\u003c\/span\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 0.75rem;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; width: 1.5rem; height: 1.5rem; border-radius: 50%; display: inline-flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n    \u003cspan\u003eAffix the modular end-plate to the last physical module on the rail to protect internal signals.\u003c\/span\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":53102145700203,"sku":"LJ72GF15-T2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/lj72gf15-t2-fejxzfl5sar.png?v=1776137803","url":"https:\/\/www.plcprotech.com\/fr\/products\/mitsubishi-electric-lj72gf15-t2-melsec-l-series-cc-link-ie-field-network-head-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}