{"product_id":"mitsubishi-electric-q64rp-melsec-q-series-power-supply-module","title":"Bloc d'Alimentation : Q64RP","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eEngineered for high-availability industrial control applications, the \u003cstrong\u003eMitsubishi Electric Q64RP\u003c\/strong\u003e is a redundant power supply module designed specifically for the MELSEC-Q Series PLC platform. This module ensures continuous, uninterrupted system operation by working in a dual-redundant configuration on compatible redundant base units. It converts an AC input voltage into stable 5V DC power to drive the CPUs, I\/O modules, and co-processors mounted on the backplane.\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eQ64RP\u003c\/strong\u003e is critical for process automation and infrastructure applications where unplanned downtime cannot be tolerated. In a redundant setup, if one power supply module fails, the secondary module seamlessly assumes the full load without interrupting system operation or causing CPU resets. Built-in diagnostic features, including dedicated status LEDs and contact terminal outputs, allow maintenance personnel to quickly identify and replace a faulted module while the control system remains fully energized.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRedundant Power Architecture:\u003c\/strong\u003e Pairs with another module on redundant base units (such as Q38RB or Q68RB) to guarantee system uptime.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHot-Swappable Design:\u003c\/strong\u003e Enables safe replacement of a faulty module while the system is powered and online, eliminating maintenance-related process interruptions.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFault Detection Relay:\u003c\/strong\u003e Features dedicated error terminals (ERR) that open or close to signal power failure or diagnostic anomalies to external monitoring systems.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWide Input Range:\u003c\/strong\u003e Operates reliably on nominal inputs ranging from 100 to 240 V AC, accommodating global voltage variations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eComprehensive Protection Circuits:\u003c\/strong\u003e Includes integrated overcurrent and overvoltage protection to safeguard sensitive backplane components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eWater and wastewater treatment facilities requiring continuous pump and filtration control.\u003c\/li\u003e\n  \u003cli\u003eOil and gas refining, petrochemical processing, and pipeline monitoring systems.\u003c\/li\u003e\n  \u003cli\u003ePower generation plants, substations, and utility management systems.\u003c\/li\u003e\n  \u003cli\u003eAutomotive assembly lines and continuous manufacturing processes where unexpected halts lead to high material scrap costs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003e\u003cth\u003eParameter\u003c\/th\u003e\u003c\/strong\u003e\n      \u003cstrong\u003e\u003cth\u003eSpecification\u003c\/th\u003e\u003c\/strong\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eMitsubishi Electric\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel \/ Part Number\u003c\/td\u003e\n      \u003ctd\u003eQ64RP\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSeries\u003c\/td\u003e\n      \u003ctd\u003eMELSEC-Q Series\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModule Type\u003c\/td\u003e\n      \u003ctd\u003eRedundant Power Supply Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n      \u003ctd\u003e100 to 240 V AC (85 to 264 V AC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Frequency\u003c\/td\u003e\n      \u003ctd\u003e50 \/ 60 Hz (+\/-5%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Apparent Power\u003c\/td\u003e\n      \u003ctd\u003e160 VA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Voltage\u003c\/td\u003e\n      \u003ctd\u003e5 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Current\u003c\/td\u003e\n      \u003ctd\u003e8.5 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOvercurrent Protection\u003c\/td\u003e\n      \u003ctd\u003e9.3 A or higher\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOvervoltage Protection\u003c\/td\u003e\n      \u003ctd\u003e5.5 to 6.5 V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEfficiency\u003c\/td\u003e\n      \u003ctd\u003e65% or higher\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStatus Display\u003c\/td\u003e\n      \u003ctd\u003ePOWER LED (Green), ERR LED (Red)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAllowable Momentary Power Failure Time\u003c\/td\u003e\n      \u003ctd\u003eWithin 20 ms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd\u003e0 to 55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature\u003c\/td\u003e\n      \u003ctd\u003e-25 to 75 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eApproximate Weight\u003c\/td\u003e\n      \u003ctd\u003e0.45 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eTerminal Name\u003c\/th\u003e\n      \u003cth\u003eFunction \/ Description\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eL \/ N\u003c\/td\u003e\n      \u003ctd\u003ePower input terminals (100 to 240 V AC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLG\u003c\/td\u003e\n      \u003ctd\u003eLine Ground terminal (half-voltage potential filter ground)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFG\u003c\/td\u003e\n      \u003ctd\u003eFrame Ground terminal (connected to protective earth)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eERR\u003c\/td\u003e\n      \u003ctd\u003eRedundant power supply error output terminals (relay contact output)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBase Compatibility:\u003c\/strong\u003e Mount the Q64RP exclusively on MELSEC-Q redundant power supply main base units (e.g., Q38RB) or redundant power supply extension base units.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding Requirements:\u003c\/strong\u003e Always ground the FG and LG terminals using class D grounding (ground resistance of 100 ohms or less) to minimize electromagnetic interference and guarantee safety.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use M3.5 screws and standardized crimp terminals for all wiring. Tighten terminal screws to a torque spec of 0.59 to 0.88 N·m.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVentilation:\u003c\/strong\u003e Ensure a minimum clearance of 30 mm above and below the module to maintain natural convection airflow and keep operating temperatures below 55 degC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE (EMC Directive, Low Voltage Directive)\u003c\/li\u003e\n  \u003cli\u003eUL \/ cUL Listed\u003c\/li\u003e\n  \u003cli\u003eKC (Korean Certification for electromagnetic compatibility)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":53102231388523,"sku":"Q64RP","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/Q64RP-ptsldxv54gw.png?v=1776137951","url":"https:\/\/www.plcprotech.com\/fr\/products\/mitsubishi-electric-q64rp-melsec-q-series-power-supply-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}