{"product_id":"mpc4-200-510-076-114-vibro-meter-vm600-machinery-protection-card","title":"Carte de protection machine Vibro-Meter VM600 MPC4 200-510-076-114","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMPC4 200-510-076-114 (MPC4)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-reliability machinery protection card and a core element of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVibro-Meter VM600\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatform. This specialized module is engineered for the continuous monitoring of critical rotating machinery, including steam\/gas turbines, large compressors, and industrial fans. It provides four dynamic signal input channels and two dedicated speed (tachometer) channels. By executing high-speed signal processing and autonomous alarm logic, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMPC4 200-510-076-114\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures immediate protective action (tripping) to safeguard assets from excessive vibration, shaft displacement, or overspeed conditions, even in the event of a higher-level system communication failure.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration (Deep Dive)\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e200-510-076-114\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodel is a high-specification version of the MPC4 series, typically used in SIL-rated safety environments.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Signal Processing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEquipped with high-performance digital signal processors (DSPs) to perform real-time FFTs, tracking filters, and peak-to-peak measurements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVME Bus Communication:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSeamlessly integrates with the VM600 backplane for data exchange with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCPUM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecard, while maintaining a local hardware safety path that operates independently of the rack controller.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Versatility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFully compatible with a wide array of transducers, including\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTQ4xx\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eproximity sensors,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCAxxx\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eaccelerometers, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCExxx\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003evelocity sensors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOn-board Relay Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports complex \"Voting Logic\" (e.g., 1-out-of-2, 2-out-of-3) when paired with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIOC4T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eI\/O card, ensuring high availability and minimizing the risk of false trips.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMPC4 200-510-076-114\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVibro-Meter (Meggitt)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSwitzerland\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Dynamic (Vibration), 2 Tachometer (Speed)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e11 W (Nominal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-25 to 65 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eA\/D Resolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16-bit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSuitable for SIL 2 applications\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.60 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the \"114\" suffix differ from standard MPC4 versions?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e114\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003evariant indicates a specific firmware and hardware revision level tailored for modern\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSI (Turbine Supervisory Instrumentation)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003estandards. It often includes enhanced diagnostic capabilities and specific coating options for protection against atmospheric corrosives in industrial environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I configure the MPC4 200-510-076-114 without the CPUM card?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. While the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMPC4\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eexecutes its protection logic autonomously once configured, the initial setup, setpoint adjustment, and firmware management must be performed via the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVM600 MPS (Machinery Protection System)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esoftware through the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCPUM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erack controller.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the purpose of the \"Danger\" and \"Alert\" LEDs on the front panel?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAlert\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Yellow) LED indicates that a measurement has exceeded the first threshold, suggesting maintenance is required. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDanger\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Red) LED indicates the second threshold has been breached, typically triggering a relay to shut down the machine to prevent damage.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIOC4T Rear Pairing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMPC4 200-510-076-114\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emust be installed in the front of the VM600 rack, directly aligned with an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIOC4T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecard in the rear. The connection is made through the VME P2 connector; ensure no pins are bent during insertion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Tightening:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen wiring the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIOC4T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eterminals, ensure a torque of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0.5 to 0.6 Nm\u003c\/strong\u003e. Loose connections in vibration monitoring can lead to \"signal spikes\" that the MPC4 may interpret as a genuine machine fault.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding Strategy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe cable shielding for sensors must be tied to the \"Shield\" terminal on the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIOC4T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eonly. Floating the shield at the sensor end is critical to prevent ground loops that introduce 50\/60 Hz noise into the processing path.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMPC4 200-510-076-114\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003estands out for its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDeterministic Safety Path\u003c\/strong\u003e. Unlike software-based PLCs, the MPC4 utilizes a hard-coded logic path for alarm triggering, ensuring a response time of less than\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e20 milliseconds\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom fault detection to relay activation. Its robust thermal management design allows it to operate in the high-ambient-temperature environments found in turbine halls without the need for external cooling fans, significantly increasing the Mean Time Between Failures (MTBF).\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"VIBRO-METER","offers":[{"title":"Default Title","offer_id":52695203479915,"sku":"VM600 MPC4 200-510-076-114","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/vibro-meter-vm600-mpc4-200-510-076-114-machinery-protection-card-fxwjaj1le2m_57f4e62c-da0c-4940-affa-106596c53f8c.jpg?v=1766130595","url":"https:\/\/www.plcprotech.com\/fr\/products\/mpc4-200-510-076-114-vibro-meter-vm600-machinery-protection-card","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}