{"product_id":"mu-taoy22-honeywell-tdc-3000-analog-output-16-point-fta","title":"MU-TAOY22 Honeywell TDC 3000 Sortie analogique 16 points FTA","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMU-TAOY22\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16-Point Analog Output Field Termination Assembly (FTA)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell TDC 3000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTPS (TotalPlant Solution)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystems. This module provides 16 channels of isolated 4-20 mA signals, serving as the critical interface between the process controller and field final control elements such as control valves, actuators, and variable speed drives. Engineered for mission-critical reliability, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMU-TAOY22\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports redundant configurations with standby manual capabilities, ensuring continuous process control even during hardware transitions or maintenance.\u003c\/p\u003e\n\u003ch3\u003eFunctional Precision \u0026amp; Load Management\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMU-TAOY22\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis built for extreme signal stability, featuring a resolution of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e±0.05%\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand a calibrated accuracy of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e±0.35%\u003c\/strong\u003e. It handles resistive loads up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e750 Ω\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eat 20 mA, making it compatible with a wide array of long-distance field wiring and high-impedance devices. With a settling time of only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4 ms\u003c\/strong\u003e, the module ensures that control actions are executed almost instantaneously. Furthermore, its advanced surge withstand capability (per ANSI\/IEEE C37.90.1) protects the control system from electrical transients often found in heavy industrial environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMU-TAOY22\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4-20 mA (DC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDirectly Settable Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 mA, 2.9 mA to 21.1 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e± 0.05%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSettling Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 ms (to 98% of final value)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperature Stability\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±0.02% Full Scale \/ °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Resistive Load\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e750 Ω @ 20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFTA Size\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSize B\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTermination Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eType C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the \"Redundant w\/ Stby Man\" feature?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMU-TAOY22\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed for high-availability loops. It supports redundant I\/O modules where a secondary \"Standby\" module is ready to take over. The \"Stby Man\" capability allows for manual control or a safe transition during a failover, with a maximum gap to the field of only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e20 ms\u003c\/strong\u003e, ensuring that sensitive control valves do not \"glitch\" or change position during a module swap.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the module handle output ripple?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module is engineered with a peak-to-peak output ripple of less than\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100 mV\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eat power line frequency. This low-noise performance is vital for precision control applications where high-frequency oscillations could cause premature mechanical wear on control valve positioners or actuators.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if the digital input code exceeds normal limits?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMU-TAOY22\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ehas an absolute maximum current output of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e24 mA\u003c\/strong\u003e. This allows the system to drive signals into \"over-range\" for diagnostic purposes or to fully stroke a valve, while still protecting the internal circuitry from thermal damage due to excessive current draw.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Engineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFTA Mounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInstall the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMU-TAOY22\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eon a standard Honeywell FTA mounting channel. Ensure the \"Size B\" footprint is accounted for in the cabinet layout to allow for proper cable routing and access to the Type C terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding \u0026amp; Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo maintain the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e±0.05% linearity\u003c\/strong\u003e, field cable shields should be terminated at the designated ground bar. This minimizes electromagnetic interference (EMI) that could affect the 4-20 mA signal integrity over long distances.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostic Check:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module performs an internal switching hardware diagnostic\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eonce per minute\u003c\/strong\u003e. During commissioning, verify that the AO readback accuracy (±4%) is monitored by the system software to ensure the field loop is healthy and the actual current matches the controller's demand.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMU-TAOY22\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erepresents the industry standard for robust analog output management in legacy DCS environments. Its ability to provide stable, linear 4-20 mA signals under varying temperature and humidity conditions makes it a \"fit and forget\" component for critical infrastructure. For B2B procurement, choosing original\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell MU-TAOY22 FTAs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures that your TDC 3000 system maintains its original engineering specifications and safety margins, protecting your process from the risks of unplanned downtime and signal drift.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52705785545067,"sku":"MU-TAOY22","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/mu-taoy22-ymgxvnndrz2_f87db1e3-b9ba-4b82-9107-1a45c12c5137.jpg?v=1766659779","url":"https:\/\/www.plcprotech.com\/fr\/products\/mu-taoy22-honeywell-tdc-3000-analog-output-16-point-fta","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}