{"product_id":"omron-3g3jz-a2037-sysdrive-3g3jz-series-inverter","title":"Variateur série SYSDRIVE 3G3JZ Omron 3G3JZ-A2037","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Omron 3G3JZ-A2037 is a compact, variable frequency AC drive within the SYSDRIVE 3G3JZ series, engineered to provide precise speed regulation for three-phase asynchronous motors. Operating on a 200V class three-phase electrical input, this hardware functions by converting standard line power into a variable-voltage, variable-frequency phase-to-phase sinusoidal PWM output to drive induction motors rated up to 3.7 kW. The inverter utilizes a high-efficiency V\/f control strategy with built-in torque compensation to yield a robust starting torque of 150% or greater at lower operating frequencies. Equipped with native RS-485 Modbus serial communication, the unit coordinates directly with host programmable logic controllers like the Omron CP1L series for simple positioning control, automated data monitoring, and network integration inside machine control cabinets.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMicro-sized variable frequency drive for space-restricted electrical sub-panels.\u003c\/li\u003e\n\u003cli\u003eBuilt-in multi-function digital and analog control circuit terminal blocks.\u003c\/li\u003e\n\u003cli\u003eEmbedded RS-485 Modbus RTU communication channel for digital speed profiling and status reporting.\u003c\/li\u003e\n\u003cli\u003eTorque compensation function supplying 150% output torque at 3 Hz.\u003c\/li\u003e\n\u003cli\u003eIntegrated energy-saving parameter options to maximize electrical motor operating efficiency.\u003c\/li\u003e\n\u003cli\u003eSimple macro configuration routines suitable for standard industrial applications.\u003c\/li\u003e\n\u003cli\u003eProtection framework safeguarding against line faults, overcurrent, and output short-circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMechanical transport lines, production conveyors, and localized material handling systems.\u003c\/li\u003e\n\u003cli\u003eStandard industrial centrifugal pumps, booster stations, and fluid mixing apparatus.\u003c\/li\u003e\n\u003cli\u003eExhaust blowers, supply fans, and localized HVAC commercial air-handling equipment.\u003c\/li\u003e\n\u003cli\u003ePackaging machinery lines, including wrapping machines and small-scale friction feeders.\u003c\/li\u003e\n\u003cli\u003eMachine-tool spindle control and automated indexing mechanisms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003ePower Requirements\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eInput Voltage Class\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e3-phase 200V Level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eRated Input Voltage\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e3-phase (3-wire) 200 to 240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eInput Voltage Fluctuation Range\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e200 V -15% to 240 V +10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eInput Frequency\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eInput Frequency Fluctuation Range\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e± 5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eOutput Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eMaximum Applicable Motor Capacity\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e3.7 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eRated Output Voltage\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e3-phase: 200 to 240 V (proportional to input voltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eOutput Control Method\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003ePhase-to-phase sinusoidal modulation PWM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eTorque Performance\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e150% or more torque output at 3 Hz via torque compensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eEnvironmental\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eEnclosure Model A: Panel-mounting \/ Closed wall mounting (IP20 minimum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eAmbient Operating Temperature\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e-10°C to +50°C (Close-mounting spacing: -10°C to +40°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eAmbient Operating Humidity\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e90% RH maximum (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eStorage Environment\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eMust be free from corrosive or flammable gases, salt mist, and dense metallic dust\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eMechanical\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eInstallation Orientation\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eVertical wall mounting format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eShipping Weight\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e3 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Orientation:\u003c\/strong\u003e Mount the drive vertically against a flat wall or sub-panel surface within the electrical enclosure. Do not install the unit horizontally or in an inverted plane.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Clearances:\u003c\/strong\u003e Maintain prescribed clearance distances from adjacent components or enclosure inner surfaces to allow for proper air circulation from the lower cooling fan up through the upper ventilation vents.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Safeguards:\u003c\/strong\u003e Ensure main power supply line lines are completely de-energized and verified via instrumentation for less than 10 minutes prior to opening the front wiring terminal shield block cover.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Isolation Warning:\u003c\/strong\u003e Connect exclusively three-phase induction motor loads to the U\/T1, V\/T2, and W\/T3 power terminals. Never join AC mains supply electricity lines to these output connections, as doing so will cause immediate, severe hardware destruction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Wiring Integrity:\u003c\/strong\u003e Keep sensitive low-voltage control terminal block lines separate from main power lines or motor feeder wires inside the panel routing channels to suppress electrostatic noise and high-frequency EMI.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Connection:\u003c\/strong\u003e Terminate a heavy gauge earth grounding lead directly to the structural grounding bolt. Ensure the overall path resistance measures 100 Ω or less for this 200V class machinery.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhat is the maximum electrical motor capacity supported by this module?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eThis model is rated to run three-phase motors with a maximum capacity of 3.7 kW.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWhat specific voltage supply class does this drive belong to?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eIt belongs to the 3-phase 200V class, with an operational input range of 200 to 240 VAC.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDoes this unit support network communication out of the box?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eYes, it features a native RS-485 port supporting standard Modbus serial protocols.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWhat is the environmental index or chassis type of this specific housing?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eIt is an Enclosure Type A layout, matching an IP20 minimum rating suitable for panel mounting.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCan this VFD run on a single-phase 230V input line?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eNo, this unit is engineered strictly to handle a 3-phase, 3-wire incoming power supply line.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWhat type of motor control logic is utilized by the internal processor?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eIt utilizes phase-to-phase sinusoidal PWM modulation using adjustable torque compensation functions.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHow should this product be oriented when installing inside a control panel?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eIt must always be installed vertically on a wall or flat sub-panel to allow the internal fans to draw cooling air upward.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWhat safety measures are needed for short-circuit line faults?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eA molded case circuit breaker (MCCB) or protective industrial fuses calibrated to the drive ratings must be wired in series with the input power supply lines.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWhat happens if AC input power lines are mistakenly wired to the motor output terminals?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eConnecting AC main line power directly to the motor output terminals (U\/T1, V\/T2, W\/T3) will cause terminal hardware damage and destroy the drive internal components.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWhat is the physical weight of this model package for logistics purposes?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eThe baseline shipping weight of this inverted drive assembly is rated at 3 Kg.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":53077923529067,"sku":"3G3JZ-A2037","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3g3jz-a2037-amo3a3zazxg.png?v=1775733423","url":"https:\/\/www.plcprotech.com\/fr\/products\/omron-3g3jz-a2037-sysdrive-3g3jz-series-inverter","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}