{"product_id":"omron-3g3jz-a4015-sysdrive-3g3jz-series-inverter","title":"Variateur série SYSDRIVE 3G3JZ Omron 3G3JZ-A4015","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Omron 3G3JZ-A4015 is an intelligent variable frequency AC drive within the SYSDRIVE 3G3JZ series, engineered to deliver speed regulation and torque control for three-phase induction motors. Operating on a 400V class three-phase electrical input, this hardware functions by converting standard plant alternating current into an adjustable voltage and frequency output. The system structure is designated as an open-type Enclosure Model A configuration, making it suitable for direct sub-panel integration. Designed to run electrical motors up to a maximum capacity of 1.5kW, the drive facilitates local control panel interfacing alongside standard automation architecture integration. It acts as an actuator base within modular machinery control topologies, matching the network demands of modern industrial control enclosures.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAdjustable frequency AC motor controller configured for precise speed regulation loops.\u003c\/li\u003e\n\u003cli\u003eIntegrated Enclosure Model A chassis layout designed for panel-mounting setups.\u003c\/li\u003e\n\u003cli\u003eOptimized hardware layout handling three-phase 400V level incoming plant power distribution.\u003c\/li\u003e\n\u003cli\u003eHigh-efficiency thermal dissipation construction supporting close continuous integration inside electrical panels.\u003c\/li\u003e\n\u003cli\u003eBuilt-in programming logic routines structured to accommodate variable machinery load curves.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMechanical transport networks, industrial sorting systems, and distribution conveyors.\u003c\/li\u003e\n\u003cli\u003eStandard commercial booster pumps, centrifugal fluid systems, and water treatment skids.\u003c\/li\u003e\n\u003cli\u003eFacility air handling units, exhaust blowers, and industrial supply fan setups.\u003c\/li\u003e\n\u003cli\u003eModular packaging machinery lines, commercial strapping, and small box sealing units.\u003c\/li\u003e\n\u003cli\u003eLocalized indexing tables, specialized machine tool feeds, and material wrapping apparatus.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003ePerformance\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eSeries Name\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eSYSDRIVE 3G3JZ Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eMaximum Applicable Motor Capacity\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e1.5kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003ePower Requirements\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eVoltage Class\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e400V level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eInput Configuration\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e3-phase AC400V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eMechanical\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eEnclosure Classification\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eModel A: Panel-mounting models (IP20 min) \/ Closed wall mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eShipping Weight\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e3 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVertical Chassis Alignment:\u003c\/strong\u003e Secure the drive assembly vertically against a flat, unpainted metal backplate inside the sub-panel. Do not attempt horizontal or upside-down installation configurations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Clearance Zones:\u003c\/strong\u003e Provide adequate open boundary margins above and below the cooling heatsinks to allow unimpeded natural or forced vertical air convection inside the enclosure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Line Separation:\u003c\/strong\u003e Route high-voltage AC mains input wires and motor output feeder lines inside wire ducts completely separated from low-voltage analog signal cables or digital control lines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInductive Load Protection:\u003c\/strong\u003e Connect the output terminals exclusively to three-phase induction motor terminals. Never connect plant AC mains distribution lines to the drive output block.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-Impedance Grounding:\u003c\/strong\u003e Fasten a heavy-duty copper safety earth ground conductor directly from the structural chassis ground bolt to the main panel earth distribution network.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum applicable motor power rating for this inverter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe drive is rated to operate three-phase induction motors with a maximum capacity of 1.5kW.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat specific voltage supply class is required to power this device?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis model is built for the 400V class, requiring a 3-phase AC400V line power configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the Enclosure Model A designation represent in terms of construction?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eModel A represents a panel-mounting model configuration with an IP20 minimum rating or a closed wall mounting profile.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the physical shipping weight of this specific hardware package?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe total logistics or physical shipping weight of this drive module is 3 Kg.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I install this variable frequency drive horizontally inside a shallow box?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the module must be mounted in a vertical plane to prevent heat build-up and ensure proper operational cooling airflow.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it safe to wire single-phase AC electricity into the input terminals of this unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, this drive is engineered explicitly to operate on a 3-phase electrical supply line.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat kind of load can be connected to the output block?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe output block is built exclusively to run standard three-phase AC induction motors matching the unit capacity ratings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAre special cable considerations necessary for the motor connection?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, use shielded or braided motor cables connected 360 degrees to the panel ground plane to restrict high-frequency electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow long should I wait after turning off power before touching the terminal wires?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAlways wait for the manufacturer specified time, usually at least 10 minutes, to ensure all internal high-voltage capacitors are fully discharged.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this inverter housing provide standalone weatherproofing outside of a panel?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, with an IP20 minimum rating, it is defined as an in-panel device that must be housed inside a protected industrial control cabinet.\u003c\/p\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":53077908685163,"sku":"3G3JZ-A4015","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3g3jz-a4015-cvsn4zyki1b.png?v=1775733430","url":"https:\/\/www.plcprotech.com\/fr\/products\/omron-3g3jz-a4015-sysdrive-3g3jz-series-inverter","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}