{"product_id":"omron-cp1l-em40dr-d-cp1l-series-plc-cpu-module","title":"CP1L-EM40DR-D | Omron | Automate programmable haute performance avec Ethernet intégré","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eEngineered for flexible machine control and seamless industrial networking, this \u003cstrong\u003eOmron CP1L-EM40DR-D\u003c\/strong\u003e controller integrates \u003cstrong\u003eembedded Ethernet communication\u003c\/strong\u003e with robust processing capability in a compact form factor. By eliminating the need for external option boards for basic networking, this CP1L series CPU optimizes panel space and simplifies network commissioning. The platform features a high-density \u003cstrong\u003e40-point I\/O configuration\u003c\/strong\u003e consisting of 24 inputs and 16 robust relay outputs, making it highly suitable for material handling, auxiliary system control, and packaging applications.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEmbedded Ethernet Port:\u003c\/strong\u003e Supports FINS\/TCP communication for easy connection to host systems, HMIs, and programming software without auxiliary modules.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Speed Counter Inputs:\u003c\/strong\u003e Features 4 axes of 100 kHz high-speed counters for precise positioning and rotary encoder feedback.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSubstantial Memory Capacity:\u003c\/strong\u003e 10K steps program capacity and ample data memory to accommodate complex sequencing and scaling instructions.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExpandable Architecture:\u003c\/strong\u003e Compatible with CP1W series expansion I\/O and analog units for flexible system scaling.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRelay Outputs:\u003c\/strong\u003e Rugged 16-point relay output stage capable of direct pilot duty load switching.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePackaging Equipment:\u003c\/strong\u003e Ideal for wrapping, cartoning, and labelling machines requiring localized Ethernet monitoring and basic motion feedback.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConveyor and Material Handling:\u003c\/strong\u003e Manages distribution networks, sorters, and lifters utilizing integrated Ethernet peer-to-peer data links.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWater and Wastewater Systems:\u003c\/strong\u003e Controls small-scale pumping, aeration, and filtration stations with direct HMI integration.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHVAC Control Panels:\u003c\/strong\u003e Provides logical sequence execution for industrial chillers, boilers, and air handling units.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left; border: 1px solid #cbd5e0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold;\"\u003eSpecification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eOmron\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eModel Reference\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eCP1L-EM40DR-D\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eProduct Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eCP1L-EM (Embedded Ethernet Series)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003ePower Supply Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e24 VDC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eProgram Capacity\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e10K steps\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eTotal Built-In I\/O Points\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e40 Points\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eBuilt-In Inputs\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e24 DC Inputs\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eBuilt-In Outputs\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e16 Relay Outputs\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eHigh-Speed Counters\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e100 kHz, 4 axes\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eNetwork Communications\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1 x RJ45 Ethernet Port (FINS\/TCP, Socket Services)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eNet Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e555 g max\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e2.0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #1a365d; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe CP1L-EM40DR-D with integrated Ethernet replaces configurations that historically relied on basic CP1L-M series units fitted with add-on CP1W-CIF41 Ethernet boards. This reduces hardware points of failure and saves the option board slot for other serial interfaces (such as RS-232C or RS-422A\/485). Programs created for non-Ethernet CP1L units can be migrated easily inside CX-Programmer by updating the PLC model type and adjusting network settings.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #1a365d; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eKeep in mind that because this unit uses relay outputs, it does not support high-speed pulse outputs (such as PTO for servo or stepper control). If your application requires high-speed pulse outputs, you must select a transistor output model (e.g., CP1L-EM40DT-D or CP1L-EM40DT1-D). Furthermore, ensure the inductive loads driven by the relay outputs are suppressed using external diodes or RC snubbers to protect the internal physical contacts from premature pitting and contact welding.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #1a365d; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1.5rem;\"\u003eTo configure the embedded Ethernet interface, ensure your programming PC is set to the same subnet mask. The default IP address setup of the CP1L-EM can be set using CX-Programmer. When wiring high-speed inputs to the high-speed counters, route the encoder cables inside shielded twisted pairs separate from high-power AC lines to prevent noise-induced false triggers on the high-speed digital inputs.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 15px; margin-bottom: 1.5rem; border-radius: 4px;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 5px;\"\u003eCRITICAL WARNING\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0; font-size: 0.95rem;\"\u003eAlways isolate the primary AC\/DC power sources feeding the control enclosure prior to installing, wiring, or removing this controller. Confirm that the 24 VDC power supply matches the polarity requirements of the power terminals to prevent catastrophic damage to the internal mainboard.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748; padding-top: 3px;\"\u003eMount the PLC unit on a standard 35mm DIN rail inside a dry, clean enclosure, maintaining at least 50mm clearance on all sides to allow proper convection cooling.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748; padding-top: 3px;\"\u003eConnect the 24 VDC power lines to the dedicated power terminal blocks. Wire the functional ground (FG) terminal directly to a low-impedance ground bar.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748; padding-top: 3px;\"\u003eInsert the RJ45 Ethernet communication cable until you hear a clear mechanical click, routing it away from high-noise cables such as variable frequency drive outputs.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":53077923201387,"sku":"CP1L-EM40DR-D","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/CP1L-EM40DR-D-1h5h4bxb1kr.png?v=1775733600","url":"https:\/\/www.plcprotech.com\/fr\/products\/omron-cp1l-em40dr-d-cp1l-series-plc-cpu-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}