{"product_id":"omron-cp1l-m30dr-d-cp1l-programmable-logic-controller","title":"CP1L-M30DR-D | Omron | Contrôleur programmable haute performance avec Ethernet intégré","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eEngineered for advanced machine control applications, the Omron \u003cstrong\u003eCP1L-M30DR-D\u003c\/strong\u003e programmable logic controller (PLC) provides compact yet highly performant automation capabilities. This micro-PLC integrates embedded Ethernet functionality, enabling direct connection to factory networks, remote monitoring systems, and supervisory software without the need for additional communication cards.\u003c\/p\u003e\n\n\u003cp\u003eOperating on a stored program system, the \u003cstrong\u003eCP1L-M30DR-D\u003c\/strong\u003e utilizes cyclic scanning with immediate I\/O refreshing to ensure deterministic processing times. Programmed primarily using standard ladder diagrams, the unit also supports function blocks written in either ladder logic or structured text (ST) languages. This dual-language support provides engineers with the flexibility to implement complex mathematical algorithms alongside standard sequential control routines.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Speed Processing:\u003c\/strong\u003e Executes basic instructions in 0.55 microseconds and special instructions in 4.1 microseconds.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible Memory Allocation:\u003c\/strong\u003e Features 10K steps of program capacity alongside a extensive work bit and holding area to store application data.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTask-Based Execution:\u003c\/strong\u003e Supports up to 288 tasks, split between 32 cyclic tasks and 256 interrupt tasks for modular and responsive programming.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExpandable Architecture:\u003c\/strong\u003e Connects up to three CP-series expansion or expansion I\/O units to scale physical control points as system requirements grow.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOnboard Analog Functions:\u003c\/strong\u003e Includes one integrated 0 to 10 V analog input channel with 1\/256 resolution and one analog adjustment potentiometer (range 0 to 255).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePackaging machinery control and coordination\u003c\/li\u003e\n  \u003cli\u003eMaterial handling and conveyor routing systems\u003c\/li\u003e\n  \u003cli\u003eMunicipal water treatment monitoring and small-scale pump stations\u003c\/li\u003e\n  \u003cli\u003eAutomated assembly lines and pick-and-place equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eOmron\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCP1L-M30DR-D\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eControl Method\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eStored program method\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eI\/O Control Method\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCyclic scan with immediate refreshing\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProgram Language\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLadder diagram (ST supported in function blocks)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProgram Capacity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10K steps\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBasic Instruction Execution Time\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.55 microseconds minimum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCommon Processing Time\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.4 ms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMax Subroutines\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e256\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Area\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1,600 bits (CIO 0 to CIO 99)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Area\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1,600 bits (CIO 100 to CIO 199)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHolding Area\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8,192 bits (H0 to H511)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTimers\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4,096 (T0 to T4095)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMax Expansion Units\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3 CP-series Expansion or Expansion I\/O units\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInterrupt Inputs\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e6 inputs (0.3 ms response time), 4 inputs in counter mode (5 kHz max)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAnalog Inputs\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 channel (0 to 10 V, non-isolated, 1\/256 resolution)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAnalog Adjuster\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 potentiometer (setting range 0 to 255)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eInterface Type\u003c\/th\u003e\n      \u003cth\u003eConnector \/ Connection Port\u003c\/th\u003e\n      \u003cth\u003eFunctional Assignment\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEthernet\u003c\/td\u003e\n      \u003ctd\u003eRJ45\u003c\/td\u003e\n      \u003ctd\u003eProgramming, network communication, and host link connection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAnalog Input\u003c\/td\u003e\n      \u003ctd\u003eScrew terminal block\u003c\/td\u003e\n      \u003ctd\u003e1 channel non-isolated 0 to 10 V sensor input\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExpansion Port\u003c\/td\u003e\n      \u003ctd\u003eCP-series system connector\u003c\/td\u003e\n      \u003ctd\u003eBus extension for up to 3 local I\/O modules\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Install securely on a 35 mm DIN rail inside a protective control cabinet to protect against environmental contaminants.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThermal Management:\u003c\/strong\u003e Maintain a minimum clearance of 50 mm above and below the controller to allow adequate natural convection and heat dissipation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the functional ground terminal to a dedicated ground line with a resistance of less than 100 ohms.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring Isolation:\u003c\/strong\u003e Route standard low-voltage analog and communication lines away from high-voltage AC power cables to prevent electromagnetic interference.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":53077916221803,"sku":"CP1L-M30DR-D","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/cp1l-m30dr-d-ypz44kmqyzc.png?v=1775733604","url":"https:\/\/www.plcprotech.com\/fr\/products\/omron-cp1l-m30dr-d-cp1l-programmable-logic-controller","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}