{"product_id":"omron-cp1w-ts003-cp1-series-plc-expansion-unit","title":"Unité d'extension PLC Omron CP1W-TS003 série CP1","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDesigned to expand the thermal monitoring capabilities of CP1 Series PLC systems, the \u003cstrong\u003eOmron CP1W-TS003\u003c\/strong\u003e provides high-accuracy analog temperature measurement interface options directly to the controller backplane. This expansion module enables seamless integration of external temperature sensors without requiring complex dedicated transmitters. The \u003cstrong\u003eOmron CP1W-TS003\u003c\/strong\u003e communicates natively with CP1H, CP1L, and CP1E CPU units, mapping raw sensor values directly into the PLC memory map for immediate processing within your ladder logic. Featuring a compact form factor, it minimizes DIN rail footprint while delivering robust, low-noise analog performance in challenging industrial environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eProvides 2 dedicated analog input channels specifically optimized for industrial temperature monitoring.\u003c\/li\u003e\n  \u003cli\u003eFeatures high-precision 12-bit analog-to-digital conversion for reliable process variable resolution.\u003c\/li\u003e\n  \u003cli\u003eEnables fast hardware integration with native PLC backplane communication, eliminating external network configuration.\u003c\/li\u003e\n  \u003cli\u003eCompact 50 mm width allows for high-density cabinet panel design.\u003c\/li\u003e\n  \u003cli\u003eDirect status LED indicators on the front panel display unit health and communication status.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003ePlastic extrusion and injection molding thermal control loops.\u003c\/li\u003e\n  \u003cli\u003eIndustrial heat-treatment ovens and curing furnaces.\u003c\/li\u003e\n  \u003cli\u003ePackaging machinery sealing-jaw temperature regulation.\u003c\/li\u003e\n  \u003cli\u003eFood processing pasteurization and environmental chamber logging.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2d3748;\"\u003e\n        \u003cth style=\"padding: 0.75rem;\"\u003eSpecification Parameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem;\"\u003eValue \/ Details\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eOmron\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eCP1W-TS003\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eI\/O Expansion Unit (Analog Input)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCompatible PLC Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eCP1H, CP1L, CP1E Series\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eNumber of Analog Inputs\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e2 Channels\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eResolution\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e12-Bit Converter Resolution\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eLinear Analog Input Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eNone (Dedicated Temperature Input)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e50 mm x 90 mm x 86 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eNet Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e0.225 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1.500 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #1a365d; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe CP1W-TS003 is explicitly designed for CP-series platforms. If you are migrating an older system from the CQM1 or CPM2A platforms to the CP1 family, note that older expansion modules cannot be connected to CP1 CPUs. Always ensure that the total current draw of this module along with other connected CP1W expansion units does not exceed the internal 5V or 24V power supply limitations of your specific CP1 PLC CPU.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #1a365d; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eTo maintain the integrity of the 12-bit analog conversions, shield the sensor lines carefully. Avoid routing thermocouple extension wiring in the same conduit or wire duct as high-voltage AC cables, variable frequency drive output cables, or lines feeding inductive loads. Electrostatic and magnetic interference in close proximity can induce voltage spikes, causing temperature value jitter in the PLC memory registers.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #1a365d; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDuring initial configuration in CX-Programmer, you must configure the allocated I\/O memory words according to the CP1 system manual. Ensure that unused channels are disabled in software or shorted at the terminal block to prevent open-circuit alarms or continuous conversion errors. Always use the specified thermocouple compensation cables for extension wiring to prevent measurement offsets caused by cold-junction mismatch.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eDisconnect all primary and auxiliary power supplies feeding the PLC rack and the expansion unit before mounting, removing, or wiring the module. Failure to de-energize the entire system can cause hardware damage, processor memory faults, or hazardous electrical shock.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0; margin-right: 0.75rem;\"\u003e1\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 2px;\"\u003eEnsure the CPU Unit is securely mounted on the DIN rail. Pivot the expansion module onto the DIN rail to the right of the CPU or preceding expansion unit.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0; margin-right: 0.75rem;\"\u003e2\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 2px;\"\u003eSlide the expansion unit flat against the adjacent CPU unit, then firmly press the connection bus cable into the CPU expansion connector until it locks.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0; margin-right: 0.75rem;\"\u003e3\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 2px;\"\u003eConnect the sensor shielding directly to the panel functional ground terminal. Do not connect sensor shields to the active terminal block of the module itself.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":53077905932651,"sku":"CP1W-TS003","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/cp1w-ts003-tob3k0ers3n.png?v=1775733625","url":"https:\/\/www.plcprotech.com\/fr\/products\/omron-cp1w-ts003-cp1-series-plc-expansion-unit","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}