{"product_id":"omron-cp2e-n30dr-a-cp2e-series-network-model-micro-plc","title":"Micro PLC modèle réseau série CP2E OMRON CP2E-N30DR-A","description":"\u003ch3\u003eProduct Engineering Overview\u003c\/h3\u003e\n\n\u003cp\u003e\nThe \u003cstrong\u003eCP2E-N30DR-A\u003c\/strong\u003e functions as a dual-port Ethernet-integrated micro programmable logic controller designed to bridge edge data collection with field-level real-time control. In continuous-process environments such as industrial wastewater treatment, pharmaceutical secondary packaging, and aggregate mining facilities, fieldbus communication failures instantly generate operational blind spots. This processor integrates dual built-in Ethernet switches with Modbus-TCP functionality to form resilient linear daisy-chain networks without external hardware switches. By facilitating parallel processing of motion, communication, and standard control loops, the \u003cstrong\u003eCP2E-N30DR-A\u003c\/strong\u003e eliminates system processing bottlenecks, ensuring optimal equipment performance and reduced unscheduled downtime.\n\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Configuration \u0026amp; Interface Architecture\u003c\/h3\u003e\n\n\u003cp\u003e\nThe hardware layout centers on a high-speed execution engine coupled with 30 embedded digital I\/O channels. The input block features 18 points of 24 VDC inputs, including 4 channels configured for high-speed counter functions capable of handling 100 kHz differential phase inputs for absolute rotary encoder feedback. For the output interface, 12 electromechanical relay points manage discrete power switching up to 2 A per channel, suitable for direct pilot lights and motor contactor actuation. To address expanded fieldbus demands, the dual-port Ethernet interface supports simultaneous client\/server links, allowing parallel HMI monitoring and peer-to-peer controller communication. Optional auxiliary boards permit further field extensions, supporting additional RS-232C, RS-485, or analog I\/O options.\n\u003c\/p\u003e\n\n\u003ch3\u003eOperational Parameters Matrix\u003c\/h3\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse;\"\u003e\n    \u003cthead\u003e\n        \u003ctr\u003e\n            \u003cth\u003eParameter\u003c\/th\u003e\n            \u003cth\u003ePerformance Specifications\u003c\/th\u003e\n        \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003eCP2E-N30DR-A\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003eOMRON\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003eJapan \/ China\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eController Class\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003eCP2E N-Type (Network Model)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eTotal Hardware I\/O\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e30 points\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eDiscrete Inputs\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e18 points (24 VDC; 4 channels support 100 kHz inputs)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eDiscrete Outputs\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e12 points (Relay, SPST-NO)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eElectrical Contact Rating\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e2 A at 250 VAC \/ 24 VDC per point (resistive load)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eMain Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e100 to 240 VAC, 50\/60 Hz\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eAllowable Supply Range\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e85 to 264 VAC\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eOnboard Service Power\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e300 mA at 24 VDC output\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eProgram Capacity\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e10K steps\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eData Register Memory\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e16K words\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e130 mm x 110 mm x 85 mm\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e0.60 kg\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\u003cstrong\u003eOperating Temp Range\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e-20 to 60 deg C\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eEngineering Diagnostics \u0026amp; Maintenance FAQs\u003c\/h3\u003e\n\n\u003cp\u003e\n\u003cstrong\u003eDoes the integrated dual-port Ethernet switch support separate IP addresses for each port?\u003c\/strong\u003e\n\u003c\/p\u003e\n\n\u003cp\u003e\nNo. The two Ethernet ports link directly to an internal layer-2 unmanaged network switch. They share an identical MAC address and a single IP address configuration. The design is optimized for simple hardware daisy-chaining, eliminating the need for an external switch inside the control panel enclosure.\n\u003c\/p\u003e\n\n\u003cp\u003e\n\u003cstrong\u003eCan this unit execute standard program code developed for legacy CP1E processors?\u003c\/strong\u003e\n\u003c\/p\u003e\n\n\u003cp\u003e\nYes. The CP2E architecture provides backward software compatibility with CP1E application code. Program conversion is completed directly within the CX-Programmer or Sysmac Studio environments, though communication configurations must be updated to reference the new Ethernet hardware registers.\n\u003c\/p\u003e\n\n\u003cp\u003e\n\u003cstrong\u003eWhat is the functional advantage of the CP2E extended operating temperature over older series?\u003c\/strong\u003e\n\u003c\/p\u003e\n\n\u003cp\u003e\nStandard micro PLCs fail when ambient control panels breach the 55 deg C threshold. The CP2E-N30DR-A features enhanced electronic components rated for continuous operations from -20 to 60 deg C. This extended thermal window significantly lowers cooling hardware costs in harsh outdoor environments like pumping stations.\n\u003c\/p\u003e\n\n\u003cp\u003e\n\u003cstrong\u003eHow many expansion units can be added to the CP2E-N30DR-A base unit?\u003c\/strong\u003e\n\u003c\/p\u003e\n\n\u003cp\u003e\nThe N30 CPU chassis allows the direct connection of up to 3 optional CP1W expansion modules. This configuration allows field technicians to scale up digital points, inject analog loops, or integrate temperature sensor inputs while keeping the original compact footprint.\n\u003c\/p\u003e\n\n\u003ch3\u003eField Commissioning \u0026amp; Safety Protocols\u003c\/h3\u003e\n\n\u003cul\u003e\n    \u003cli\u003e\n        \u003cp\u003e\n        \u003cstrong\u003eChassis Orientation and Airspace:\u003c\/strong\u003e Mount the controller horizontally onto a grounded 35 mm DIN rail. Maintain a minimum vertical boundary clearance of 50 mm above and below the device housing to facilitate natural thermal convection. This spatial gap prevents heat-induced processing faults during heavy relay-switching operations up to 60 deg C.\n        \u003c\/p\u003e\n    \u003c\/li\u003e\n\n    \u003cli\u003e\n        \u003cp\u003e\n        \u003cstrong\u003eFunctional Grounding Integrity:\u003c\/strong\u003e Connect a dedicated green\/yellow ground wire of at least 2.0 mm square from the Functional Ground (FG) screw terminal directly to the main system earth copper busbar. A low-resistance ground path shields internal microcontrollers from common-mode industrial noise.\n        \u003c\/p\u003e\n    \u003c\/li\u003e\n\n    \u003cli\u003e\n        \u003cp\u003e\n        \u003cstrong\u003eInductive Suppression Standards:\u003c\/strong\u003e Relay contact lifespans decrease rapidly under inductive switching. Wire an external RC snubber circuit parallel across any AC solenoid or contactor load. For 24 VDC inductive elements, implement a commutating freewheeling diode across the device terminals.\n        \u003c\/p\u003e\n    \u003c\/li\u003e\n\n    \u003cli\u003e\n        \u003cp\u003e\n        \u003cstrong\u003eEthernet Noise Isolation:\u003c\/strong\u003e Route Ethernet network infrastructure lines through distinct metallic wireways. Keep communication links separated from heavy 400 VAC motor distribution or variable frequency drive (VFD) output phases by a minimum clearance of 300 mm to maintain data integrity.\n        \u003c\/p\u003e\n    \u003c\/li\u003e\n\n    \u003cli\u003e\n        \u003cp\u003e\n        \u003cstrong\u003eTerminal Screws Mechanical Tension:\u003c\/strong\u003e Utilize crimped insulated ferrules for all field control and power supply connections. Tighten all M3 terminal block screws to a consistent torque rating of 0.5 N-m to prevent loose contact points or high-resistance paths.\n        \u003c\/p\u003e\n    \u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":53077928804715,"sku":"CP2E-N30DR-A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/CP2E-N30DR-A.png?v=1779353424","url":"https:\/\/www.plcprotech.com\/fr\/products\/omron-cp2e-n30dr-a-cp2e-series-network-model-micro-plc","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}