{"product_id":"omron-cp2e-n40dt-d-cp2e-series-programmable-controller","title":"Automate programmable série Omron CP2E-N40DT-D CP2E","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eOptimized for decentralized industrial networks, the \u003cstrong\u003eOmron CP2E-N40DT-D\u003c\/strong\u003e micro-PLC integrates essential automation control with native Ethernet capabilities. This controller is designed specifically for machinery setups requiring remote monitoring, multi-node fieldbus communications, and compact footprint configurations. Running on a robust \u003cstrong\u003e24 VDC power supply\u003c\/strong\u003e, it features 40 built-in digital I\/O points and an integrated dual-port Ethernet switch, drastically reducing wiring complexity and eliminating the need for external network switch hardware.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual Ethernet Ports:\u003c\/strong\u003e Built-in Ethernet switch capabilities supporting Modbus TCP Client\/Server and Ethernet\/IP communications.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Density IO:\u003c\/strong\u003e Offers 24 digital inputs (24 VDC) and 16 transistor sinking outputs in a space-saving DIN-rail form factor.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePositioning Capabilities:\u003c\/strong\u003e Includes 4 axes of high-speed counter inputs (up to 100 kHz) and 4 axes of pulse outputs for precise motion and positioning control.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBattery-Free Operation:\u003c\/strong\u003e Employs high-capacity flash memory to retain program logic and critical system data, reducing preventative maintenance schedules.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExtended Temperature Envelope:\u003c\/strong\u003e Engineered to operate reliably across a wide thermal range without requiring active panel cooling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePackaging \u0026amp; Labeling Machinery:\u003c\/strong\u003e Synchronized feeding, wrapping, and high-speed registration mark detection.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConveyor \u0026amp; Material Handling Systems:\u003c\/strong\u003e Smart routing, decentralized sorting, and sensor-driven lane control via Ethernet\/IP.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePumping and Fluid Control:\u003c\/strong\u003e Remote telemetry integration, pressure monitoring, and pump staging protocols.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBuilding Infrastructure \u0026amp; HVAC:\u003c\/strong\u003e Localized air handling unit automation, climate profiles, and Modbus TCP sub-metering.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 12px; text-align: left; font-weight: bold; color: #1a365d;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 12px; text-align: left; font-weight: bold; color: #1a365d;\"\u003eTechnical Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003eOmron Industrial Automation\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003eCP2E-N40DT-D\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eSeries Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003eCP2E Series (N-Type \/ Network Model)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eSupply Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003e24 VDC (Acceptable range: 20.4 to 26.4 VDC)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eTotal Built-in I\/O\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003e40 Points (24 Inputs, 16 Outputs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eDigital Inputs\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003e24 points, 24 VDC (Sinking \/ Sourcing, IEC 61131-2 Type 1 compliant)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eDigital Outputs\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003e16 points, Transistor (Sinking)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eOutput Load Capacity\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003e24 VDC, 0.3 A max per point; 3.6 A max per common terminal\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eProgram Capacity\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003e10,000 steps\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eData Memory Capacity\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003e16,000 words\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eIntegrated Interfaces\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003e2x RJ45 Ethernet ports (with internal switch functionality), 1x USB 2.0 (Type-B)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003e-20 to 60 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eStorage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003e-25 to 70 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003e0.85 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003e165 mm x 125 mm x 100 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 12px; text-align: left; font-weight: bold; color: #1a365d;\"\u003eTerminal \/ Interface\u003c\/th\u003e\n        \u003cth style=\"padding: 12px; text-align: left; font-weight: bold; color: #1a365d;\"\u003eSignal \/ Purpose\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003ePower Terminals\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003e24 VDC (+ \/ -) \u0026amp; Functional Ground (FG)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eInput Terminal Block (Top)\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003eChannels 00 to 11 (High-speed and standard inputs with common terminals)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eOutput Terminal Block (Bottom)\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003eChannels 00 to 07 (Sinking transistor configurations with shared common grounds)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eDual Ethernet Ports (RJ45)\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003eIntegrated switch ports supporting EtherNet\/IP and Modbus TCP peer connection\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px; font-weight: bold;\"\u003eUSB Port (Type-B)\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px;\"\u003eProgramming, parameterization, and diagnostic monitoring connection\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe CP2E-N40DT-D serves as a natural upgrade path for legacy CP1E-N40DT-D controllers. When converting programs inside Omron CX-Programmer (version 9.72 or higher), ensure that the target PLC architecture is set correctly to enable access to the expanded memory and advanced function blocks of the CP2E. Please note that while input and output footprint assignments remain identical, the built-in Ethernet settings must be explicitly defined under the CP2E network settings module to initialize the internal Ethernet switch registers.\u003c\/p\u003e\n\n\u003ch4\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhen mounting this unit horizontally within standard control panels, passive heat dissipation is highly efficient. However, if the ambient cabinet temperature exceeds 50 degC, it is critical to de-rate the simultaneous input-on ratio. Specifically, avoid running more than 60% of the inputs simultaneously at 24 VDC to prevent internal optical isolation degradation. Additionally, since the outputs are sinking transistor configurations, external clamp diodes must be installed on inductive loads (such as DC solenoids or relays) to protect the internal transistors from high-voltage flyback transients.\u003c\/p\u003e\n\n\u003ch4\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe built-in dual RJ45 Ethernet ports function as an internal Ethernet switch and share a single IP address. Do not create physical loops in your Ethernet layout unless utilizing an external managed switch with Rapid Spanning Tree Protocol (RSTP) enabled elsewhere in the network topology. For reliable high-speed counter positioning up to 100 kHz, utilize shielded twisted-pair (STP) cabling for inputs 00 through 03, terminating the shield securely at the panel's star ground block rather than at the PLC's signal common terminal.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e Prior to wiring, installation, or servicing of this unit, completely de-energize the master control panel. Verify the absence of voltage across all terminals using a calibrated digital multimeter. Failure to isolate power from the main DC line can result in catastrophic electronic damage to the internal bus logic, driver chips, or field wiring components.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eSnap the CP2E-N40DT-D controller securely onto standard 35 mm DIN rail inside a well-ventilated enclosure, leaving a minimum of 20 mm space above and below the device for passive air currents.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eConnect the functional ground terminal directly to the main copper backplate using a low-impedance ground strap to suppress high-frequency electrical noise.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eWire the 24 VDC power supply to the dedicated power terminal pins using wire ferrules with a minimum cross-section of 0.5 to 1.25 mm2 (AWG 20 to 16).\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eSecurely tighten the terminal block screws to a torque rating of 0.5 Nm to prevent high resistance contacts and thermal load failure over prolonged operation.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":53077900132715,"sku":"CP2E-N40DT-D","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/cp2e-n40dt-d-gmxqgxwsglx.png?v=1775733639","url":"https:\/\/www.plcprotech.com\/fr\/products\/omron-cp2e-n40dt-d-cp2e-series-programmable-controller","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}