{"product_id":"omron-cpm1a-30cdr-d-v1-sysmac-compact-plc-cpu-module","title":"SYSMAC CPM1A-30CDR-D-V1","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eOperating on a 24 VDC power supply, the Omron CPM1A-30CDR-D-V1 micro-PLC provides a highly consolidated control platform for discrete manufacturing applications. Designed to fit into tight panel spaces, this unit integrates both processing and local I\/O channels directly into a single compact housing. The \u003cstrong\u003eOmron CPM1A-30CDR-D-V1\u003c\/strong\u003e features 18 built-in DC inputs and 12 robust relay outputs, making it ideal for managing small-scale machinery, conveyor systems, and dedicated OEM equipment. Its version 1 designation indicates enhanced logic instruction processing speeds and expanded compatibility with modern programming utilities such as CX-Programmer.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAll-in-One Architecture:\u003c\/strong\u003e Combines power supply, CPU, 18 inputs, and 12 outputs in one physical unit.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Speed Counter:\u003c\/strong\u003e One high-speed counter input point capable of handling high-speed pulse inputs up to 5 kHz (single phase) or 2 kHz (two phase).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible Input Configuration:\u003c\/strong\u003e 24 VDC inputs can be wired in either sink or source configurations to match external sensor topologies.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeavy-Duty Relay Outputs:\u003c\/strong\u003e Supports switching capacities up to 2 A per point for direct control of solenoids, contactors, and indicators.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExpandable Design:\u003c\/strong\u003e Compatible with CPM1A series expansion I\/O blocks to dynamically scale control points as application requirements evolve.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eSmall-scale packaging machines and wrapping systems\u003c\/li\u003e\n  \u003cli\u003eConveyor tracking, sorting, and material handling diverters\u003c\/li\u003e\n  \u003cli\u003eHVAC fan, pump, and damper scheduling controls\u003c\/li\u003e\n  \u003cli\u003eDedicated test fixtures and component testing stations\u003c\/li\u003e\n  \u003cli\u003eSub-assembly control nodes in larger distributed plant networks\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 0.5rem; font-weight: bold;\"\u003eSpecification Parameter\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 0.5rem; font-weight: bold;\"\u003eTechnical Value \/ Rating\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eOmron Industrial Automation\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eCPM1A-30CDR-D-V1\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProduct Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eSysmac CPM1A\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eInput Power Supply\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e24 VDC (Acceptable range: 20.4 to 26.4 VDC)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePower Consumption\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e20 W maximum\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOnboard Inputs\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e18 points (24 VDC, Sink\/Source compatible)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOnboard Outputs\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e12 points (Relay outputs, 2 A per point max, 250 VAC \/ 30 VDC)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProgram Capacity\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e2,048 words (Sysmac instruction format)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eData Memory Capacity\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eRead\/Write: 1,024 words (DM area)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0 to 55 degC (Non-condensing)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eMounting Method\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e35mm DIN rail or panel surface mount via integrated brackets\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0.65 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e140 x 110 x 95 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 0.5rem; font-weight: bold;\"\u003eTerminal \/ Port\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 0.5rem; font-weight: bold;\"\u003eFunction \/ Connection Details\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePower Terminal Block\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e+24V, -24V, and Functional Earth (FG) terminal for system power supply.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eInput Terminals (00 to 11)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eInputs 00 through 02 support high-speed hardware interrupts and counter inputs. Remaining inputs function as standard discrete inputs.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOutput Terminals (00 to 07)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eRelay contact terminals grouped with shared commons. Ensure load current does not exceed terminal limits.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePeripheral Port\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eMulti-functional programming connection port. Connects to handheld programming consoles or PC-based software (CX-Programmer) via a CPM1-CIF01 or CPM1-CIF11 interface adapter.\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe -V1 version is a direct drop-in replacement for the legacy CPM1A-30CDR-D module. It maintains identical mounting footprints and electrical pinouts. If updating an older system, you can migrate CX-Programmer files without modifications to the physical wiring harness. For complete modernization, you may consider the Omron CP1E-N30S1DT-D, but this will require software instruction mapping adjustments within the programmer environment.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhen deploying the relay output variant to switch highly inductive AC or DC loads (such as magnetic starter coils or pneumatic valves), external surge protection is absolutely essential. Running these inductive loads without transient suppressors (such as varistors or RC snubbers) causes electrical arcing across the internal micro-relay contacts, leading to contact welding and premature CPU failure.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eAlways ensure that the functional ground terminal is connected to a low-resistance earth ground (under 100 ohms) using 14 AWG or larger wire. Inductive noise coupling from adjacent VFD motor leads can corrupt high-speed counter signal lines. Route input wires and high-speed counter encoder cables through a separate duct from high-voltage AC power lines to protect signal integrity.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eNever wire or configure this PLC while the power supply is active. Isolate all upstream electrical feeds before touching terminal connections. Confirm that the input voltage matches the specified 24 VDC range to prevent permanent thermal or circuit damage to the internal logic boards.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 2px;\"\u003eMount the CPM1A module horizontally onto a 35mm DIN rail, locking the bottom mounting clips securely. Leave at least 50mm of open space around the unit for natural convection cooling.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 2px;\"\u003eConnect the 24 VDC external supply to the power terminals. Avoid routing the DC supply line in parallel with high-voltage motor wires.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 2px;\"\u003eVerify that terminal block screws are torqued between 0.5 N-m and 0.6 N-m to prevent loose contacts or stripped threads.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 2px;\"\u003eApply power, check the status LEDs on the front cover (PWR should be green), and upload the software configuration using CX-Programmer via the peripheral port.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":53077906522475,"sku":"CPM1A-30CDR-D-V1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/CPM1A-30CDR-D-V1-twoxxzaul3n.png?v=1775733656","url":"https:\/\/www.plcprotech.com\/fr\/products\/omron-cpm1a-30cdr-d-v1-sysmac-compact-plc-cpu-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}