{"product_id":"omron-cs1w-da08c-cs1-series-8-channel-analog-output-module","title":"CS1W-DA08C | Omron | Module de sortie analogique 8 canaux","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eProcessing of analog signals within the Omron CS1 PLC architecture is handled with high precision by the \u003cstrong\u003eOmron CS1W-DA08C\u003c\/strong\u003e analog output module, which provides eight independent channels for process control loops. This high-density module mounts directly onto a CS1-series CPU rack or expansion rack, converting digital values within the PLC memory into standard voltage or current outputs. Each channel can be configured independently for various signal ranges, allowing the controller to interface simultaneously with different types of field actuators, control valves, and speed regulators. Built with industrial-grade isolation and a detachable terminal block, the CS1W-DA08C ensures reliable performance and minimized downtime during field servicing.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEight Independent Analog Outputs:\u003c\/strong\u003e Supports up to 8 field devices from a single module slot, optimizing rack space.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible Signal Configuration:\u003c\/strong\u003e Output ranges can be set separately for each channel via the PLC's DM area settings.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRemovable Terminal Block:\u003c\/strong\u003e Simplifies field wiring and allows rapid module replacement without disconnecting individual field wires.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial Noise Immunity:\u003c\/strong\u003e High-grade isolation between the internal PLC bus and external field circuitry protects the control architecture.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSeamless System Integration:\u003c\/strong\u003e Fully compatible with Omron CS1-series backplanes and configurable via CX-Programmer software.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eProportional control valve and damper positioning in combustion and HVAC systems.\u003c\/li\u003e\n  \u003cli\u003eSpeed reference signaling for variable frequency drives (VFDs) and servo controllers.\u003c\/li\u003e\n  \u003cli\u003eAnalog output re-transmission to chart recorders, panel indicators, or data loggers.\u003c\/li\u003e\n  \u003cli\u003eSet-point distribution to secondary loop controllers in complex chemical or thermal processes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eSpecification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eOmron\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eCS1W-DA08C\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eModule Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eAnalog Output Module\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eNumber of Analog Outputs\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e8 channels\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eOutput Signal Ranges (Voltage)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e1 to 5 V, 0 to 10 V, 0 to 5 V, -10 to 10 V\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eOutput Signal Ranges (Current)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e4 to 20 mA\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eSignal Selection Method\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eSet separately for each output channel via PLC memory\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eExternal Connection\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eRemovable terminal block\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eInternal Current Consumption (5 VDC)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e0.13 A\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eExternal Current Consumption (24 VDC)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e0.25 A (listed as 25V in legacy reference data)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e0 to 55 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eJapan\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e1.5 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e150 mm x 135 mm x 50 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe CS1W-DA08C is standard for systems requiring high-density voltage\/current outputs. It differs from the CS1W-DA08V in connection style; the \"C\" suffix denotes a terminal block interface rather than a high-density connector, simplifying direct wiring in standard control panels. When migrating legacy C500-series hardware to CS1, this module is the designated modern replacement for C500-DA001\/DA005 units, though addressing structures in CX-Programmer must be updated to match the CS1 DM-area allocations.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eA common field failure point is the loss of the external 24 VDC power supply to the module. If external power drops below critical levels, the module will trigger an error, and all outputs will default to their de-energized states (typically 0V or 0mA, depending on safe-state configuration). PLC logic should always monitor the module’s health status bits and handle interlocks to prevent process surges or uncontrolled valve travel during a power loss event.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eTo ensure high signal integrity, use twisted-pair shielded cables for all analog runs and ground the shields at only one end (typically at the PLC panel ground bar). Ensure the rotary unit number switches on the front of the CS1W-DA08C are set correctly before powering up the rack; these switches define the starting address of the allocated DM words where individual channel ranges and conversion parameters are written.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cp style=\"margin: 0; font-weight: bold; color: #9b2c2c;\"\u003eCRITICAL WARNING:\u003c\/p\u003e\n  \u003cp style=\"margin: 0.5rem 0 0 0; color: #9b2c2c;\"\u003eDe-energize the entire PLC rack and turn off all external 24 VDC power supplies before installing, removing, or performing maintenance on the module. Hot-swapping the module can result in permanent hardware damage, CPU faulting, or unexpected actuator movement in the field.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e1\u003c\/div\u003e\n    \u003cp style=\"margin: 0; color: #2d3748;\"\u003eSet the Unit Number rotary switch on the front panel of the module to a unique value matching your CX-Programmer I\/O allocation.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e2\u003c\/div\u003e\n    \u003cp style=\"margin: 0; color: #2d3748;\"\u003eAlign the module's top and bottom guides with the target slot on the CS1 backplane and press the module firmly until it clicks into place.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e3\u003c\/div\u003e\n    \u003cp style=\"margin: 0; color: #2d3748;\"\u003eConnect the pre-wired terminal block to the front of the module and tighten the retaining screws to secure the interface.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e4\u003c\/div\u003e\n    \u003cp style=\"margin: 0; color: #2d3748;\"\u003eApply 24 VDC external power to the designated terminals, power up the PLC rack, and download the configuration data to begin commissioning.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":53077921464683,"sku":"CS1W-DA08C","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/CS1W-DA08COmronOutputModule8Analog-zjsrur02yzq.png?v=1775733697","url":"https:\/\/www.plcprotech.com\/fr\/products\/omron-cs1w-da08c-cs1-series-8-channel-analog-output-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}