{"product_id":"omron-drt2-id16-devicenet-transistor-remote-i-o-terminal","title":"Terminal I\/O distant à transistor DeviceNet Omron DRT2-ID16","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eExecuting digital signal collection within industrial fieldbus architectures, the Omron DRT2-ID16 operates as a high-density remote digital input module designed for seamless integration into DeviceNet network architectures. This terminal block features \u003cstrong\u003e16 NPN inputs\u003c\/strong\u003e with a shared positive common, streamlining the routing of field sensor wires directly to centralized controllers without complex local distribution wiring.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eKey Technical Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Density Channels:\u003c\/strong\u003e Supports up to 16 digital inputs in a single space-saving block layout.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated DeviceNet Powering:\u003c\/strong\u003e Internal control circuitry is powered directly from the communication cable connector to simplify installation and reduce point-to-point power loops.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSecure Mechanical Connections:\u003c\/strong\u003e Outfitted with robust M3 screw terminals to prevent loose wires in high-vibration heavy industrial machinery.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSmart Monitoring Diagnostics:\u003c\/strong\u003e Embedded system diagnostics monitor operating status parameters to prevent unexpected network downtime.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eAutomated assembly systems and industrial packaging machinery lines.\u003c\/li\u003e\n  \u003cli\u003eDistributed digital I\/O signal collection in standard industrial control panels.\u003c\/li\u003e\n  \u003cli\u003eConveyor control, logistics sorters, and material handling processing lines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold; width: 35%;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eOmron\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eDRT2-ID16\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eTransistor Remote I\/O Terminal\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCommunication Protocol\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eDeviceNet\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eInput Specifications\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e16 points, NPN (+ common)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eWiring Connection\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eM3 Screw terminals\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eInternal Circuit Power\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eSupplied from DeviceNet network connector\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eRated I\/O Power Supply\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e24 VDC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e-10 to 55 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eStorage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e-25 to 65 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eAmbient Humidity\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e25% to 85% (non-condensing)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eUnit Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e0.14 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e0.35 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe DRT2-ID16 represents standard NPN logic remote I\/O within the Omron DeviceNet family. For installations requiring PNP sensor interfaces, evaluate the counterpart model \u003cstrong\u003eDRT2-ID16-1\u003c\/strong\u003e, which utilizes positive-logic (- common) input circuitry. These modules share identical physical dimensions and mounting footprint for ease of hardware swaps during control cabinet modifications.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eEnsure complete compliance with the physical layout requirements of the DeviceNet network. Do not exceed maximum bus length recommendations. To limit signal reflections and packet degradation, verify that a 121-ohm terminating resistor is installed on both physical ends of the trunk line. Ensure the external I\/O power supply remains separate from the network communication power line to maintain electrical isolation boundaries.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe node address must be set using the physical rotary switches on the module face. Always isolate power before making changes to these rotary switches, as new node address configurations will not take effect dynamically until a full hardware power cycle occurs.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e\n  \u003cspan style=\"color: #9b2c2c;\"\u003eDe-energize all power sources, including the DeviceNet network communication lines and field-side auxiliary I\/O power, before mounting, wiring, or configuring the node address rotary switches. Physical contact with live connections can result in equipment damage or operational interruptions.\u003c\/span\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 1.75rem; height: 1.75rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0; margin-right: 0.75rem;\"\u003e1\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eSnap the terminal base securely onto standard 35mm symmetrical DIN rail within a clean, dry, protected industrial enclosure.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 1.75rem; height: 1.75rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0; margin-right: 0.75rem;\"\u003e2\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eConfigure the desired node address utilizing the rotary switches on the unit front prior to powering up the system.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 1.75rem; height: 1.75rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0; margin-right: 0.75rem;\"\u003e3\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eInsert the five-wire DeviceNet connector plug into the matching terminal receptacle, confirming correct color-coded wire positions.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 1.75rem; height: 1.75rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0; margin-right: 0.75rem;\"\u003e4\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eWire the NPN sensors to the M3 screw terminals, ensuring all connections are tightened to the recommended mechanical torque specification.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":53077913633131,"sku":"DRT2-ID16","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/DRT2-ID16-3yq2tnqcbau.png?v=1775733717","url":"https:\/\/www.plcprotech.com\/fr\/products\/omron-drt2-id16-devicenet-transistor-remote-i-o-terminal","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}