{"product_id":"omron-h7cx-awd1-n-h7cx-series-multifunction-counter-tachometer","title":"Compteur\/tachymètre multifonction Omron H7CX-AWD1-N série H7CX  ","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eOperating as a dual-preset digital control device, the \u003cstrong\u003eOmron H7CX-AWD1-N\u003c\/strong\u003e regulates industrial process timing and counting applications across high-speed manufacturing lines. This highly configurable 1\/16 DIN instrument functions seamlessly as a 1-stage counter, 2-stage counter, total counter, batch counter, dual counter, or tachometer. Engineered with a negative transmissive LCD display, it provides highly legible process value readouts that dynamically shift color (red\/green) based on output status to give operators immediate visual feedback on the shop floor.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMulti-functional Configuration:\u003c\/strong\u003e Instantly selectable operation modes including Preset Counter, Total Prescaling Counter, Batch Counter, Dual Counter, and Tachometer.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual-Stage Setting:\u003c\/strong\u003e Supports factory-set 2-stage setting output controls for precise pre-scale warning and final limit control.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDynamic Color-Change Display:\u003c\/strong\u003e 6-digit character display changes between red and green based on output state or parameter configurations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible Signal Input:\u003c\/strong\u003e Accepts NPN\/PNP open collector inputs or dry contact switch inputs with software-selectable count speed limits.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIP66 Front Panel Protective Rating:\u003c\/strong\u003e NEMA 4X equivalent dust and water protection ensures reliable performance in washdown environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eHigh-speed manufacturing and packaging batch run controls.\u003c\/li\u003e\n  \u003cli\u003eRotational speed tracking and conveyor belt tachometer monitoring.\u003c\/li\u003e\n  \u003cli\u003eCut-to-length material cutting machines requiring primary slowdown and final stop signals.\u003c\/li\u003e\n  \u003cli\u003eCoiling, spooling, and winding machine rotational turns count management.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications Table\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eOmron\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eH7CX-AWD1-N\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eSeries\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eH7CX-N\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eType\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eStandard Type (Screw Terminal)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eDigits\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e6 Digits (-99999 to 999999)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eSettings\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e2-Stage Presettings\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eSupply Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e12 to 24 VDC \/ 24 VAC at 50\/60 Hz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOutput Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eContact (SPST-NO) and Transistor (NPN Open Collector) Outputs\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eMax. Count Speed\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eSelectable 30 Hz or 5 kHz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eDisplay\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e7-segment negative transmissive LCD with red\/green backlight change\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-10 to 55 degC (with no icing or condensation)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eProduct Dimensions\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e48 mm x 48 mm (1\/16 DIN front panel) x 84 mm (depth)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0.25 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe \"H7CX-AWD1-N\" replaces older generation \"H7CX-AWD1\" non-N models. Key benefits of the \"-N\" suffix include enhanced key protection parameter isolation and upgraded, brighter display segments. When executing a migration, note that physical panel cutout sizing of 45x45 mm remains completely identical, requiring zero mechanical mounting alterations.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhen deploying the unit on low-voltage AC\/DC systems (12-24 VDC \/ 24 VAC), verify that common-mode electrical noise from neighboring Variable Frequency Drives (VFDs) is minimized. In electrically noisy environments, input signal lines (CP1\/CP2) should be physically routed away from the main power feed lines to prevent false counts or microsecond input triggers.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eAlways configure the counting speed selector based on the sensor element type. If using mechanical limit switches or relay contacts as count inputs, lock the speed limit parameter to 30 Hz. Running a mechanical switch at the default 5 kHz setting will cause contact bounce to register as multiple false counts. Reserve the 5 kHz frequency setting exclusively for high-speed proximity switches or rotary encoders.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cp style=\"margin: 0; font-weight: bold; color: #9b2c2c;\"\u003eCRITICAL WARNING:\u003c\/p\u003e\n  \u003cp style=\"margin: 0.5rem 0 0 0; color: #9b2c2c;\"\u003eEnsure all primary input power is fully de-energized and locked out before attempting wire insertion or extraction on the back terminal block. Contact with energized terminals on low-voltage lines can cause damage to integrated digital logic boards if static discharge occurs.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"display: flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eInsert the counter chassis through the standard 45 mm x 45 mm panel cutout from the front, ensuring the rubber sealing gasket sits flush against the panel surface to maintain its water-resistant IP66 rating.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"display: flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eSlide the plastic mounting adapter from the rear of the panel forward until it locks firmly onto the notches of the counter housing, compressing the gasket.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"display: flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eWire the back screw terminals matching the wiring label. Connect the control inputs (CP1, CP2, and Reset) using shielded twisted-pair cables with the shield grounded at only one end to eliminate ground loop current interferences.\u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":53077905277291,"sku":"H7CX-AWD1-N","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/h7cx-awd1-n-0cjhy1za4aq.png?v=1775733840","url":"https:\/\/www.plcprotech.com\/fr\/products\/omron-h7cx-awd1-n-h7cx-series-multifunction-counter-tachometer","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}