{"product_id":"omron-k3hb-xvd-abcd1-100-240vac-k3hb-series-process-indicator","title":"Omron|K3HB-XVD-ABCD1 100-240VAC| Indicateur de processus","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nDesigned for high-precision measurement discrimination in industrial systems, the \u003cstrong\u003eOmron K3HB-XVD-ABCD1 100-240VAC\u003c\/strong\u003e digital process indicator provides real-time visualization and control of critical voltage and current loop signals. This panel meter features a dynamic \u003cstrong\u003edual-color display\u003c\/strong\u003e that can toggle between green and red, allowing control operators to quickly identify out-of-bounds parameters from a distance. Operating with a high-speed \u003cstrong\u003e20 ms sampling period\u003c\/strong\u003e, it tracks rapid process transients and feeds reliable data to auxiliary monitoring systems via external event inputs.\n\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Speed AD Conversion:\u003c\/strong\u003e Capable of sampling analog field inputs 50 times per second (20 ms updates) for real-time responsiveness.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVisual Limit Alarm:\u003c\/strong\u003e Integrated comparative output indicators with programmable color-switching (green\/red backlight) for immediate status recognition.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrend Position Meter:\u003c\/strong\u003e Visual bar graph indicator monitors operating trends and limit proximity on the main faceplate.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShallow Enclosure:\u003c\/strong\u003e Low-profile case with a mounting depth of only 95 mm behind the front bezel, maximizing wire-way clearance inside compact panels.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTwo-Point Scaling:\u003c\/strong\u003e Straightforward calibration setup converts custom analog signal spans directly into user-defined engineering units.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnvironmental Protection:\u003c\/strong\u003e Front panel construction achieves NEMA 4X \/ IP66 ingress protection when paired with the supplied sealing gasket.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSensor Loop Monitoring:\u003c\/strong\u003e Real-time scaling and display of 0-10V, 1-5V, or 4-20mA industrial transmitter inputs.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDynamic Pressure \u0026amp; Flow Tracking:\u003c\/strong\u003e Ideal for high-speed hydraulic or pneumatic pressure sensing applications requiring fast sampling.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAutomated OEM Machinery:\u003c\/strong\u003e Compact visual instrumentation for localized diagnostic readouts and safety threshold discrimination.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWashdown Environments:\u003c\/strong\u003e Food, beverage, and chemical processing lines requiring washdown-resistant panel components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 0.75rem; font-weight: bold;\"\u003eSpecification Parameter\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 0.75rem; font-weight: bold;\"\u003eValue \/ Detail\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eOmron\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eModel Part Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eK3HB-XVD-ABCD1 100-240VAC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eDevice Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eProcess Indicator \/ Panel Meter\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePower Supply Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e100 to 240 VAC, 50\/60 Hz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eSampling Period\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e20 ms (50 samples per second)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eDisplay Technology\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e7-segment digital display with red\/green comparative backlight option\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eEnclosure Rating (Front)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eNEMA 4X (indoor use), equivalent to IP66\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eEnclosure Depth\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e95 mm behind the front panel bezel\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eSafety Conformity\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eUL listed, CE marking compliant\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eJapan\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1.3 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e150 x 120 x 110 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #1a365d; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nWhen replacing older Omron digital process meters (such as legacy K3NX units), note that the 1\/8 DIN panel cutout dimensions are matching, but terminal designations and wiring terminal block arrangements are completely different. External event input levels may also require scaling adjustment within the internal parameters of the K3HB software menu compared to predecessor models.\n\u003c\/p\u003e\n\n\u003ch4 style=\"color: #1a365d; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nIn environments with high-frequency electromagnetic interference, such as adjacent to variable frequency drives (VFDs) or heavy motor contactors, the high-speed 20 ms sampling system of the K3HB is susceptible to visual display jitter. It is highly recommended to shield input lines, ground the shield at only one point, and adjust the digital filter parameter (digital filter average processing) within the K3HB's setup memory to stabilize the readout.\n\u003c\/p\u003e\n\n\u003ch4 style=\"color: #1a365d; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nFor precise scaling, set up the input range first before applying voltage to the signal inputs. Use the linear conversion parameters to define the physical high\/low limits. Ensure that the terminal screws are torqued to 0.5 N-m to maintain secure connection integrity under thermal expansion and industrial vibration.\n\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e Prior to attempting installation, wiring, or inspection of this process indicator, fully isolate and lockout the main 100-240VAC power supply source. Failure to completely de-energize the panel wiring can result in severe electrical shock, component destruction, or operational system faults.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; min-width: 24px; height: 24px; border-radius: 50%; margin-right: 0.75rem; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003e\n    Prepare a standard 1\/8 DIN panel cutout (92 mm wide x 45 mm high). Smooth out any rough metal edges or burrs.\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; min-width: 24px; height: 24px; border-radius: 50%; margin-right: 0.75rem; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003e\n    Mount the watertight rubber packaging ring around the meter's bezel and push the unit through the cutout from the front of the panel.\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; min-width: 24px; height: 24px; border-radius: 50%; margin-right: 0.75rem; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003e\n    Slide the provided mounting bracket adapter over the unit housing from the rear of the panel. Tighten the clamping screws evenly until the front watertight packaging is fully compressed.\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; min-width: 24px; height: 24px; border-radius: 50%; margin-right: 0.75rem; font-weight: bold; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003e\n    Wire the AC power line (terminals for 100-240VAC) using crimp terminals. Ensure the analog sensor shielding is grounded to the control cabinet ground bar.\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":53077920350571,"sku":"K3HB-XVD-ABCD1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/K3HB-XVD-ABCD1-2aytivh2rdz.png?v=1775733859","url":"https:\/\/www.plcprotech.com\/fr\/products\/omron-k3hb-xvd-abcd1-100-240vac-k3hb-series-process-indicator","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}