{"product_id":"omron-ns8-tv00b-v2-ns-series-programmable-terminal-hmi","title":"NS8-TV00B-V2 | Omron | Terminaux programmables HMI série NS","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nFor machine-level monitoring and user control, the \u003cstrong\u003eOmron NS8-TV00B-V2\u003c\/strong\u003e serves as a robust operator terminal within the NS Series lineup. This unit offers visualization through an \u003cstrong\u003e8.4-inch TFT color display\u003c\/strong\u003e featuring VGA resolution, making it suitable for complex automated panels and manufacturing floor configurations. By using resistive touch technology, operators can execute precise adjustments and command overrides even when wearing industrial work gloves.\n\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Visibility Display:\u003c\/strong\u003e Equipped with a vibrant 8.4-inch TFT active-matrix color LCD with wide viewing angles.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVGA Resolution:\u003c\/strong\u003e High-density 640 x 480 dot matrix ensures clean text rendering and sharp graphical representation of control loops.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eResistive Touch Panel:\u003c\/strong\u003e High-durability analog resistive screen allows for flexible layout design without grid boundaries.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual Serial Ports:\u003c\/strong\u003e Two standard RS-232C communication channels facilitate simultaneous connection to PLCs, temperature controllers, or peripheral printers.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRobust Protective Bezel:\u003c\/strong\u003e Industrial black casing rated for demanding shop floor environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eHigh-speed packaging machinery and sorting line interfaces.\u003c\/li\u003e\n  \u003cli\u003eAutomotive assembly cell visualization and monitoring stations.\u003c\/li\u003e\n  \u003cli\u003eWater treatment facilities and chemical process control terminals.\u003c\/li\u003e\n  \u003cli\u003eCustom test benches and environmental chamber management.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eOmron\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eNS8-TV00B-V2\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eDisplay Technology\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eTFT Active Matrix Color LCD\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eScreen Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e8.4 inches\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eResolution\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e640 x 480 dots (VGA)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOnboard Ethernet\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eNo\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eCase Color\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eBlack\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eInput Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e24 VDC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eStandards\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ecULus, CE\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eProduct Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e2.0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e8.0 kg (with protective packaging)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eConnector \/ Port\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eSpecification \u0026amp; Purpose\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eSerial Port A\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eRS-232C (D-sub 9-pin female) for Host\/PLC connection\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eSerial Port B\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eRS-232C (D-sub 9-pin female) for peripheral\/PLC connection\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eUSB Client Port\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eType-B connector for screen data transfer from CX-Designer\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eExpansion Slot\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eSupports optional Ethernet (NS-ETN21) or Controller Link communication boards\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #1a365d;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nThe \u003cstrong\u003eNS8-TV00B-V2\u003c\/strong\u003e serves as a direct upgrade to the legacy non-V2 or V1 NS8 screens. When importing existing programs via \u003cstrong\u003eCX-Designer\u003c\/strong\u003e, verify that the target system configuration is updated to the correct V2 software engine. To migrate to an Ethernet-enabled architecture without adding an expansion module, consider the \u003cstrong\u003eNS8-TV01B-V2\u003c\/strong\u003e as a drop-in alternative.\n\u003c\/p\u003e\n\n\u003ch4 style=\"color: #1a365d;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nBecause this display relies on passive convection cooling, it is critical to ensure proper air clearance within closed control enclosures. Operating temperatures must not exceed 50 degC. Avoid placing the resistive touchscreen panel in direct sunlight, as localized heat accumulation can cause localized expansion of the protective film, leading to inaccurate touch coordinates or false button triggers.\n\u003c\/p\u003e\n\n\u003ch4 style=\"color: #1a365d;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nDuring initial commissioning via the USB Type-B port, make sure the Omron USB device driver is pre-installed within the Windows OS prior to connection. To prevent serial data transmission errors over long RS-232C cable runs, use double-shielded twisted-pair cables and connect the functional ground (FG) terminal directly to a low-impedance earth ground (less than 100 Ohms).\n\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e Disconnect all incoming primary power feeds before installing or removing this unit. Verify zero-energy state with a calibrated test instrument to prevent electrical shock, arc-flash injury, or physical hardware destruction.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e1\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003e\n    \u003cstrong\u003ePrepare Panel Cutout:\u003c\/strong\u003e Verify that the enclosure opening matches the exact 8.4-inch template dimensions. De-burr all metal edges to prevent tearing the sealing gasket.\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e2\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003e\n    \u003cstrong\u003eInspect Waterproof Gasket:\u003c\/strong\u003e Ensure the continuous-molded waterproof seal is seated securely in the bezel channel before sliding the terminal into the cutout to guarantee IP65 protection.\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e3\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003e\n    \u003cstrong\u003eSecure Mounting Brackets:\u003c\/strong\u003e Uniformly tighten the standard mounting brackets around the perimeter to the specified torque. Do not over-tighten, as excess force can deform the front bezel.\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 28px; height: 28px; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e4\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003e\n    \u003cstrong\u003ePower Connection:\u003c\/strong\u003e Wire the dedicated 24 VDC supply terminal, paying close attention to polarity markings to prevent input fuse damage.\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":53077929263467,"sku":"NS8-TV00B-V2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ns8-tv00b-v2-tpfylmycwb3.png?v=1775733937","url":"https:\/\/www.plcprotech.com\/fr\/products\/omron-ns8-tv00b-v2-ns-series-programmable-terminal-hmi","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}