{"product_id":"omron-nx-ad3204-nx-series-analog-input-unit","title":"Unité d'entrée analogique Omron NX-AD3204 série NX","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eHigh-performance analog signal acquisition is achieved via the \u003cstrong\u003eOmron NX-AD3204\u003c\/strong\u003e analog input module, designed for integration within the Sysmac automation platform. This high-density \u003cstrong\u003eNX-Series Analog Input Unit\u003c\/strong\u003e provides 4 channels of differential current inputs optimized for 4 to 20 mA signals, delivering the reliability and precision required for demanding process control environments.\u003c\/p\u003e\n\n\u003cp\u003eOperating with a conversion speed of 250 us per point and a high-resolution performance of 1\/8000, this unit ensures synchronous high-speed data acquisition when paired with EtherCAT bus couplers. The differential input design provides superior common-mode noise rejection, protecting signal integrity from electromagnetic interference on the factory floor.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eProvides 4 differential analog input channels dedicated to current signals.\u003c\/li\u003e\n  \u003cli\u003eStandard 4 to 20 mA input range compatible with most industrial transmitters and sensors.\u003c\/li\u003e\n  \u003cli\u003eFast conversion times of up to 250 us per point for high-speed application loops.\u003c\/li\u003e\n  \u003cli\u003eHigh resolution of 1\/8000 for precise variable tracking and control.\u003c\/li\u003e\n  \u003cli\u003eDifferential input method minimizes electrical noise interference in harsh operating environments.\u003c\/li\u003e\n  \u003cli\u003eUltra-compact form factor designed for space-saving DIN rail layouts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eProcess monitoring (flow meters, pressure sensors, and level transmitters).\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater treatment facility control loops.\u003c\/li\u003e\n  \u003cli\u003eChemical processing and raw material monitoring.\u003c\/li\u003e\n  \u003cli\u003eFactory automation systems integrated via EtherCAT or EtherNet\/IP networks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eManufacturer\u003c\/strong\u003e\n      \u003ctd\u003eOmron\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003ePart Number\/Model\u003c\/strong\u003e\n      \u003ctd\u003eNX-AD3204\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eSeries\u003c\/strong\u003e\n      \u003ctd\u003eNX-Series\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eModule Type\u003c\/strong\u003e\n      \u003ctd\u003eAnalog Input\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e\n      \u003ctd\u003e4 points\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eInput Range\u003c\/strong\u003e\n      \u003ctd\u003e4 to 20 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eInput Method\u003c\/strong\u003e\n      \u003ctd\u003eDifferential input\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eResolution\u003c\/strong\u003e\n      \u003ctd\u003e1\/8000\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eConversion Time\u003c\/strong\u003e\n      \u003ctd\u003e250 us per point\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eShipping Weight\u003c\/strong\u003e\n      \u003ctd\u003e1.0 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Mount securely onto a 35 mm DIN rail within a dust-free, dry industrial enclosure.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use shielded twisted-pair cables for analog signal lines and ensure the shield is properly grounded at the functional ground terminal to prevent signal degradation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTerminal Block:\u003c\/strong\u003e Utilize the integrated push-in Plus terminal block for solderless connection of solid or ferruled wires.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Ensure ambient operating temperatures remain within official catalog limits, providing adequate ventilation space around the module rack.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":53077915042155,"sku":"NX-AD3204","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/nx-ad3204-uggwzgsxrwv.png?v=1775733952","url":"https:\/\/www.plcprotech.com\/fr\/products\/omron-nx-ad3204-nx-series-analog-input-unit","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}