{"product_id":"omron-nx102-1120-sysmac-nx1-modular-cpu","title":"NX102-1120 | Omron | CPU modulaire Sysmac NX1","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDesigned for high-speed machine control and seamless factory automation integration, the \u003cstrong\u003eNX102-1120\u003c\/strong\u003e controller brings database connectivity, motion control, and multi-network capabilities to the \u003cstrong\u003eSysmac NX1\u003c\/strong\u003e platform. This modular CPU allows for real-time synchronization of physical axes while simultaneously managing sequence control, motion pathways, and secure vertical communication.\u003c\/p\u003e\n\n\u003cp\u003eEquipped with native database connection functionality, this controller streamlines data logging and traceability by communicating directly with SQL servers. It functions as a secure bridge between production-floor hardware and enterprise-level IT infrastructure, offering reliable operations in high-throughput industrial environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSupports synchronized control of up to 4 motion axes and 4 point-to-point (PTP) axes.\u003c\/li\u003e\n  \u003cli\u003eDirect SQL database connectivity for automated data collection and storage without intermediate PCs.\u003c\/li\u003e\n  \u003cli\u003eIntegrated OPC UA server functionality for secure, standardized communication with SCADA and MES systems.\u003c\/li\u003e\n  \u003cli\u003eDual EtherNet\/IP ports and a dedicated EtherCAT Master port to handle high-bandwidth industrial networks.\u003c\/li\u003e\n  \u003cli\u003eScalable local architecture supporting up to 32 local NX-series expansion I\/O units.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eAutomotive assembly lines requiring precise multi-axis synchronization.\u003c\/li\u003e\n  \u003cli\u003eHigh-speed packaging machinery requiring synchronized motion and database logging.\u003c\/li\u003e\n  \u003cli\u003eSemiconductor fabrication processes.\u003c\/li\u003e\n  \u003cli\u003eWater treatment and environmental monitoring systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eOmron\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel\/Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNX102-1120\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSysmac NX1\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProgram Memory\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5 MB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVariables Memory\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e33.5 MB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePrimary Task Cycle Time\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 ms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMax. Synchronous Axes\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4 axes\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMax. PTP Axes\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4 axes\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMax. Total Axes (including virtual)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e15 axes\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCommunication Ports\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEtherCAT Master, EtherNet\/IP, Ethernet TCP\/IP, USB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOptional Communications\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSerial RS-232C, RS-422, RS-485 (via option boards)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMax. Remote I\/O Nodes\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e64 nodes\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLocal I\/O System\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNX I\/O Bus\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMax. Local Expansion Units\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e32 units\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100 mm x 66 mm x 100 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eApproximate Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2 kg (Shipping weight)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eInterface Type\u003c\/th\u003e\n      \u003cth\u003eFunction\/Purpose\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEtherCAT Port\u003c\/td\u003e\n      \u003ctd\u003eHigh-speed, real-time control of servo drives, remote I\/O, and vision sensors.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEtherNet\/IP Ports\u003c\/td\u003e\n      \u003ctd\u003eDual-port hub for secure network configuration, SQL server access, and host PC communication.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eUSB Port\u003c\/td\u003e\n      \u003ctd\u003ePeripheral connection for local configuration and engineering tools.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOption Board Slot\u003c\/td\u003e\n      \u003ctd\u003eDedicated slot for auxiliary serial communication interfaces.\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Install on standard 35 mm DIN rail in a vertical orientation to maintain adequate convection cooling.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eClearance:\u003c\/strong\u003e Maintain at least 20 mm of clear space above and below the unit.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Use a dedicated ground connection with a ground resistance of 100 ohms or less.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShielding:\u003c\/strong\u003e Use double-shielded twisted-pair cables for all EtherCAT and EtherNet\/IP network connections to mitigate electromagnetic interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE\u003c\/li\u003e\n  \u003cli\u003ecULus\u003c\/li\u003e\n  \u003cli\u003eKC (Korean Communications Commission)\u003c\/li\u003e\n  \u003cli\u003eRCM (Regulatory Compliance Mark)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":53077904195947,"sku":"NX102-1120","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/nx102-1120-1tdstarglw2.png?v=1775734036","url":"https:\/\/www.plcprotech.com\/fr\/products\/omron-nx102-1120-sysmac-nx1-modular-cpu","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}