{"product_id":"omron-nxeic202-nx-series-ethernet-ip-coupler","title":"Omron NXEIC202 | Omron | Unité coupleur EtherNet\/IP série NX  ","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eProviding the critical network link between local input\/output devices and a master controller, the \u003cstrong\u003eOmron NXEIC202\u003c\/strong\u003e is a dedicated bus coupler for the high-speed \u003cstrong\u003eNX I\/O Bus\u003c\/strong\u003e system. This module allows seamless distribution of inputs and outputs over standard industrial networks, enabling high-performance control architectures in space-constrained enclosures. Equipped with dual RJ45 ports, it simplifies wiring layouts by supporting flexible industrial Ethernet topologies directly on the machine level.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual Ethernet Ports:\u003c\/strong\u003e Built-in 2-port switch supports direct daisy-chain (line) connections without requiring external network switches.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Density Expansion:\u003c\/strong\u003e Direct support for up to 63 NX-series I\/O modules on a single node node-line, accommodating both standard and safety units.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePrecise Synchronization:\u003c\/strong\u003e Leverages advanced internal bus communication to maintain tight synchronization across all connected slice units.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompact Form Factor:\u003c\/strong\u003e Width of just 46 mm reduces required rail space in control panels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePackaging and Material Handling:\u003c\/strong\u003e Remote control of conveyors, sorting systems, and packaging lines over industrial networks.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAutomotive Assembly:\u003c\/strong\u003e Multi-axis station control requiring fast I\/O response times and high modularity.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDistributed Machine Control:\u003c\/strong\u003e Decoupled architectures where remote sub-panels connect back to a central host PLC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eOmron\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eModel\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eNXEIC202\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eSeries\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eNX Series\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eCommunication Protocol\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eEtherNet\/IP\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eNumber of Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e2 (RJ45 with internal switch)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eInternal I\/O Bus\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eNX Bus\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eMaximum Number of I\/O Units\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e63 units\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eProtection Degree\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eIP20\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e100 mm x 46 mm x 80 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eNet Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0.15 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1.0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold;\"\u003eTerminal \/ Port\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold;\"\u003eFunction \/ Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eEtherNet\/IP Port 1\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eRJ45 connection to network\/master controller\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eEtherNet\/IP Port 2\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eRJ45 connection to next downstream slave node (daisy chain)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eUnit Power Terminals\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e24 VDC input powering the internal coupler circuitry\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eI\/O Power Terminals\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e24 VDC input routed directly to connected I\/O units\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThis EtherNet\/IP coupler integrates natively within Sysmac Studio. Note that older firmware revisions may limit the maximum number of high-speed analog units allowed on the local bus. Always verify that your controller's configuration file matches the coupler's specific hardware revision printed on the side label.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhen packing multiple high-current digital output modules directly adjacent to the coupler, compute the total current draw on both the internal Unit Power Supply and the external I\/O Power Supply. Exceeding the standard unit power limit will cause communication timeouts on the NX Bus. Interleave additional Power Feed Units (such as the NX-PF0630) to partition current delivery zones correctly.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eFor electrical noise mitigation in high-frequency environments (such as near variable frequency drives), ensure the DIN rail itself has a low-impedance connection to the main functional ground panel. Always use STP (Shielded Twisted Pair) Cat5e or higher cabling with grounded RJ45 metal shells to prevent packet loss under high electromagnetic interference.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; border-radius: 4px;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eIsolate all electrical power sources from the main switchgear before mounting or removing the coupler. Failure to shut down control-side and field-side 24 VDC lines completely prior to physical maintenance risks damaging the delicate gold-plated internal backplane connector pins.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eSnap the coupler onto standard 35 mm DIN rail, securing it with end brackets on both sides to eliminate lateral vibration.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eConnect your incoming EtherNet\/IP communications cable to Port 1, and optional downstream daisy-chain nodes to Port 2.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eWire the independent 24 VDC Unit power supply and the 24 VDC I\/O power supply lines using ferrules to protect fine conductors.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eConfigure the host network ID via the front rotary dials before energizing the control cabinet.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":53077936669035,"sku":"NXEIC202","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/nxeic202-nhtbvkqwghs.png?v=1775734055","url":"https:\/\/www.plcprotech.com\/fr\/products\/omron-nxeic202-nx-series-ethernet-ip-coupler","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}