{"product_id":"omron-s8jx-p30024cd-s8jx-series-switch-mode-power-supply","title":"S8JX-P30024CD | Omron | Alimentation à découpage","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDesigned for stable and reliable DC distribution within industrial control systems, the Omron S8JX-P30024CD delivers regulated 24 VDC power to sensitive automated components. Featuring an integrated harmonic current suppression circuit conforming to IEC 61000-3-2, this 300W power supply mitigates noise feedback into the primary line, ensuring high performance in dense electrical cabinets. The DIN rail mounting design (indicated by the CD suffix) facilitates rapid installation, while the rugged metal enclosure and built-in cooling fan provide thermal stability under continuous heavy-duty operations.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHarmonic Suppression:\u003c\/strong\u003e Built-in Power Factor Correction (PFC) circuitry reduces electrical noise and complies with IEC 61000-3-2 standards.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOvercurrent Protection:\u003c\/strong\u003e Automatic recovery system limits output current during overloads to prevent damage to downstream field devices.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOvervoltage Protection:\u003c\/strong\u003e Shuts down the output when internal voltages exceed safe operating parameters, requiring manual power cycle to reset.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThermal Dissipation:\u003c\/strong\u003e Integrated cooling fan maintains optimal internal operating temperatures under full load conditions.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDIN Rail Integration:\u003c\/strong\u003e Factory-fitted bracket ensures robust mounting on standard 35mm top-hat rails.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTypical Industrial Applications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003ePLC systems and distributed I\/O rack power networks.\u003c\/li\u003e\n  \u003cli\u003eIndustrial sensor excitation and transmitter loops.\u003c\/li\u003e\n  \u003cli\u003e24 VDC control circuit relays and contactor coils.\u003c\/li\u003e\n  \u003cli\u003eMachine tool control panels and material handling systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold; color: #1a365d;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold; color: #1a365d;\"\u003eSpecification Values\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eOmron\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eModel Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eS8JX-P30024CD\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eInput Voltage Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e85 to 264 VAC (Single Phase, 47 to 63 Hz) or 120 to 370 VDC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eOutput Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e24 VDC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eOutput Current Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e14.0 A\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003ePower Rating\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e300 W\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eEfficiency (Typical)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e82% minimum at full load\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eVoltage Adjustment Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e-10% to +15% (via front-panel potentiometer)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eMounting Style\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e35mm DIN Rail Mount (Factory-installed metal bracket)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCooling Method\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eForced-air cooling (built-in fan)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e-20 to +60 degC (Refer to derating curves for ambient exceeding 40 degC)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eProduct Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.95 kg;\"\u003e0.95 kg (Approximate net weight)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003ePhysical Dimensions\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e249 mm x 77.6 mm x 123 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e1.50 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Terminal Assignments\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold; color: #1a365d;\"\u003eTerminal Designation\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold; color: #1a365d;\"\u003eFunction Description\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eL\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eAC Line Input Terminal (Fuses internally on Line phase)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eN\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eAC Neutral Input Terminal\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003ePE \/ Frame Ground\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eSafety Earth Ground connection (Must be bonded to main panel ground)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003e+V (Multiple Terminals)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003ePositive DC Output Terminals (24 VDC)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003e-V (Multiple Terminals)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eNegative DC Output Terminals (0 VDC Return)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch3\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe S8JX-P series was engineered as an updated alternative to standard S8JX-G models, specifically introducing harmonic current suppression to comply with broader international power grids. If replacing an older S8JX-G or transitioning to newer product lines, be aware that the S8VK-G and S8VK-WA series represent the modern replacement footprints. When switching to S8VK equivalents, verify the physical footprint and terminal layouts, as some S8VK models have a narrower width but deeper profile than the S8JX-P.\u003c\/p\u003e\n\n\u003ch3\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe S8JX-P30024CD relies on active, forced-air cooling via an integrated fan. Mounting this unit in orientations other than standard vertical DIN rail layout drastically limits heat dissipation. For standard operation, maintain a clearance of at least 20mm on both sides and 50mm above and below the device. Failure to keep these spaces free will trigger premature thermal derating or cause automatic overtemperature shutdown under high-load profiles.\u003c\/p\u003e\n\n\u003ch3\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhen connecting a 14A continuous load, copper field-wiring with a minimum gauge of 14 AWG (2.5 mm²) is highly recommended to minimize localized heating and voltage drop at the terminals. Use ring or spade terminals properly sized for M4 terminal screws. Torque all input and output terminal screws strictly to 1.2 N-m to prevent loose, high-resistance connections under heavy vibration cycles.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e Hazardous voltages are present on the primary terminals of this equipment. Ensure all upstream AC feed breakers are fully de-energized and locked out\/tagged out prior to starting installation or performing terminal maintenance. Allow at least 5 minutes post-power-down for internal capacitors to discharge fully before touching any internal or external connections.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eClip the top hook of the power supply's integrated DIN-rail mount onto the upper edge of the standard 35mm rail.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003ePress the lower portion of the enclosure firmly toward the rail until the spring-loaded DIN rail latch snaps securely into place. Verify mechanical lock by trying to tilt the unit.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eTerminate the safety ground connection to the PE terminal block using a dedicated earth wire before making any primary power or secondary DC connections.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eConnect the primary Line (L) and Neutral (N) lines, then the 24 VDC positive (+V) and negative (-V) DC lines to their respective terminal outputs. Ensure appropriate wire gauge and check torque settings.\u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":53077898953067,"sku":"S8JX-P30024CD","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/s8jx-p30024cd-mjak3ie2skp.png?v=1775734076","url":"https:\/\/www.plcprotech.com\/fr\/products\/omron-s8jx-p30024cd-s8jx-series-switch-mode-power-supply","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}